diff --git a/documents/README/YamBMS_functions.md b/documents/README/YamBMS_functions.md index 116a61d..1509f32 100644 --- a/documents/README/YamBMS_functions.md +++ b/documents/README/YamBMS_functions.md @@ -52,11 +52,28 @@ The `Float voltage` slider allows you to set the voltage used after charging is The `Inverter Offset V.` slider allows you to correct the inverter charge voltage, either because it does not respect the requested value or because your inverter is far from your batteries and there is a voltage drop. This allows you to reach the target `Bulk` or `Float` charge voltage by adding an offset. -### Max current (%) +### Max Requested Current -![Image](../../images/YamBMS_Max_Current_PCT.png "YamBMS_Max_Current_PCT") +![Image](../../images/YamBMS_Max_Requested_Current.png "Max Requested Current") -The allowed charge or discharge current is automatically calculated based on the `OCP` values โ€‹โ€‹of your BMS. The `OCP` currents of the combined BMS (not in alarm) are added together and the requested current is a percentage `0~90%` of this value. + +The required `charge/discharge current` is calculated as follows : + +1. You define a **maximum current** that can never be exceeded +2. YamBMS calculates the **maximum current** accepted by your BMS (total of OCP values โ€‹โ€‹* 0.9) +3. The temperature-based current limiting function calculates the **maximum current** `based` on the **temperature**, the **battery capacity** and the **charging_rate_table** / **discharging_rate_table** + +The **current requested** by YamBMS will be **the lowest** of these three values. + +## Requested Values + +![Image](../../images/YamBMS_Requested_Values.png "YamBMS_Requested_Values") + +These 4 sensors allow you to see what is being requested of your inverter. + +In the example below, we are in the `Float` phase at a voltage of `53.6V` and an `Inverter Offset V.` of `0.1V`. The `Requested Charge Voltage` is therefore `53.7V`. + +The `Requested Discharge Voltage` is the `UVP + 0.2` value of your BMS multiplied by the number of cells, in this example (3V * 16). ### ReBulk @@ -177,18 +194,6 @@ At about 18:08 the battery is 100% after a short balancing period. ![Image](../../images/YamBMS_Auto_EOC_Graph.png "YamBMS Auto EOC Graph") -## Requested Values - -![Image](../../images/YamBMS_Requested_Values.png "YamBMS_Requested_Values") - -These 4 sensors allow you to see what is being requested of your inverter. - -In the example below, we are in the `Float` phase at a voltage of `53.6V` and an `Inverter Offset V.` of `0.1V`. The `Requested Charge Voltage` is therefore `53.7V`. - -The `Requested Discharge Voltage` is the `UVP + 0.2` value of your BMS multiplied by the number of cells, in this example (3V * 16). - -The `Requested Charge/Discharge Current` is the `OCP` value of your BMS multiplied by the `Max current` percentage, in this example (150A * 80%). - ## Inverter Heartbeat Monitoring ![Image](../../images/YamBMS_Inverter_Heartbeat.png "YamBMS_Inverter_Heartbeat") diff --git a/images/YamBMS_Max_Current_PCT.png b/images/YamBMS_Max_Current_PCT.png deleted file mode 100644 index 79659cc..0000000 Binary files a/images/YamBMS_Max_Current_PCT.png and /dev/null differ diff --git a/images/YamBMS_Max_Requested_Current.png b/images/YamBMS_Max_Requested_Current.png new file mode 100644 index 0000000..716f882 Binary files /dev/null and b/images/YamBMS_Max_Requested_Current.png differ