Fixed Auto CVL Float lockup at Rebulk threshold
Rewrote Auto CVL from template sensor lambdas to interval lambdas, splitting each into a value sensor and a delta sensor. Fixed a bug confirmed in production: Auto CVL's Float floor coincided exactly with the Rebulk V. threshold, letting it trigger its own rebulk. The floor is now capped relative to the live target instead of a fixed chemistry constant, the Float/Stop integral term can no longer get stuck once clamped, and PI state now resets when crossing the Bulk <-> Float/Stop boundary.
This commit is contained in:
1 parent
5226455f76
commit
2cdc61e8b4
2 files changed
+347
-184
No files matched your search
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 2.5.0
|
||||
# Version : 2.6.0
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -18,8 +18,19 @@
|
||||
# along with this program. If not, see <http://www.gnu.org/licenses/gpl.html>.
|
||||
|
||||
# Originally developed by @MrPablo
|
||||
# Adapted and reorganized to an interval lambda for the new CVL core by @Sleeper85
|
||||
# Updated to support `Float` and `Stop` CVL by @Sleeper85
|
||||
|
||||
substitutions:
|
||||
# +--------------------------------------+
|
||||
# | Use the settings below with caution |
|
||||
# +--------------------------------------+
|
||||
# Auto CVL - Float : safety margin kept above `Rebulk V.` when pulling the requested charge
|
||||
# voltage down. Without it, Auto CVL can drag the pack below the rebulk threshold and trigger
|
||||
# its own rebulk, looping Float -> Bulk -> Float. Derived from `Rebulk V.` at runtime so it
|
||||
# stays correct whatever the user configures.
|
||||
auto_cvl_rebulk_margin_v: '0.5'
|
||||
|
||||
switch:
|
||||
- platform: template
|
||||
name: "Automatic Charge Voltage"
|
||||
@@ -29,7 +40,33 @@ switch:
|
||||
optimistic: true
|
||||
entity_category: config
|
||||
|
||||
sensor:
|
||||
# Auto CVL
|
||||
- platform: template
|
||||
id: yambms${yambms_id}_auto_cvl
|
||||
device_id: yambms_yambms${yambms_id}
|
||||
name: "Auto CVL"
|
||||
update_interval: never
|
||||
unit_of_measurement: V
|
||||
device_class: voltage
|
||||
state_class: measurement
|
||||
accuracy_decimals: 1
|
||||
|
||||
# Auto CVL Delta
|
||||
- platform: template
|
||||
id: yambms${yambms_id}_auto_cvl_delta
|
||||
device_id: yambms_yambms${yambms_id}
|
||||
name: "Auto CVL Delta"
|
||||
update_interval: never
|
||||
unit_of_measurement: V
|
||||
device_class: voltage
|
||||
state_class: measurement
|
||||
accuracy_decimals: 1
|
||||
|
||||
number:
|
||||
# Term to adjust the proportional gain of the auto voltage control PI logic.
|
||||
# The higher the setting, the faster the correcting response.
|
||||
# Too high a value will cause oscillation.
|
||||
- platform: template
|
||||
name: "Auto CVL Kp Term"
|
||||
id: yambms${yambms_id}_auto_cvl_kp
|
||||
@@ -42,9 +79,10 @@ number:
|
||||
initial_value: 0.05
|
||||
optimistic: true
|
||||
entity_category: config
|
||||
# Term to adjust the proportional gain of the auto voltage control PI logic.
|
||||
# The higher the setting, the faster the correcting response. Too high a value will cause oscillation.
|
||||
|
||||
# Term to adjust the integral gain of the auto voltage control PI logic.
|
||||
# The higher the setting, the more the correction response will be increased over time.
|
||||
# Too high a value will cause oscillation.
|
||||
- platform: template
|
||||
name: "Auto CVL Ki Term"
|
||||
id: yambms${yambms_id}_auto_cvl_ki
|
||||
@@ -57,8 +95,6 @@ number:
|
||||
initial_value: 0.5
|
||||
optimistic: true
|
||||
entity_category: config
|
||||
# Term to adjust the integral gain of the auto voltage control PI logic.
|
||||
# The higher the setting, the more the correction response will be increased over time. Too high a value will cause oscillation.
|
||||
|
||||
- platform: template
|
||||
name: "Auto CVL Boost Charge V."
|
||||
@@ -75,144 +111,204 @@ number:
|
||||
optimistic: true
|
||||
entity_category: config
|
||||
|
||||
sensor:
|
||||
# +--------------------------------------+
|
||||
# | Auto Charge Voltage Control |
|
||||
# +--------------------------------------+
|
||||
- platform: template
|
||||
id: auto_cvl
|
||||
update_interval: 1s # must have the same value as the "dt" variable in the lamda below
|
||||
unit_of_measurement: V
|
||||
device_class: voltage
|
||||
internal: true
|
||||
filters:
|
||||
- round: 1
|
||||
lambda: |-
|
||||
// Variables
|
||||
interval:
|
||||
- interval: 1s # must have the same value as the `dt` variable in the lamda below
|
||||
then:
|
||||
# +--------------------------------------+
|
||||
# | Auto Charge Voltage Control |
|
||||
# +--------------------------------------+
|
||||
- lambda: |-
|
||||
// Variables
|
||||
|
||||
// Bulk : protects a runner max_cell_v against the Bulk target
|
||||
static float integral_bulk = 0.0; // Integral term initialization
|
||||
static float prev_integral_bulk = 0.0; // Prior Integral term initialization
|
||||
|
||||
// Float / Stop : compensates the pack average_cell_v against the current Float/Stop target
|
||||
// (a separate PI state : the tracked quantity changes nature at the Bulk <-> Float/Stop boundary)
|
||||
static float integral_avg = 0.0;
|
||||
static float prev_integral_avg = 0.0;
|
||||
// Bulk : protects a runner max_cell_v against the Bulk target
|
||||
static float integral_bulk = 0.0; // Integral term initialization
|
||||
static float prev_integral_bulk = 0.0; // Prior Integral term initialization
|
||||
|
||||
// Float / Stop : compensates the pack average_cell_v against the current Float/Stop target
|
||||
// (a separate PI state : the tracked quantity changes nature at the Bulk <-> Float/Stop boundary)
|
||||
static float integral_avg = 0.0;
|
||||
static float prev_integral_avg = 0.0;
|
||||
|
||||
float cell_count = id(yambms${yambms_id}_cell_count).state;
|
||||
float bulk_voltage = id(yambms${yambms_id}_bulk_voltage).state;
|
||||
float float_voltage = id(yambms${yambms_id}_float_voltage).state;
|
||||
float balance_delta = id(yambms${yambms_id}_balance_trigger_voltage).state;
|
||||
float max_cell_v = id(yambms${yambms_id}_max_cell_voltage).state;
|
||||
float total_voltage = id(yambms${yambms_id}_total_voltage).state;
|
||||
float cell_count = id(yambms${yambms_id}_cell_count).state;
|
||||
float bulk_voltage = id(yambms${yambms_id}_bulk_voltage).state;
|
||||
float float_voltage = id(yambms${yambms_id}_float_voltage).state;
|
||||
float balance_delta = id(yambms${yambms_id}_balance_trigger_voltage).state;
|
||||
float max_cell_v = id(yambms${yambms_id}_max_cell_voltage).state;
|
||||
float total_voltage = id(yambms${yambms_id}_total_voltage).state;
|
||||
|
||||
float kp = id(yambms${yambms_id}_auto_cvl_kp).state; // Proportional gain, adjust as needed
|
||||
float ki = id(yambms${yambms_id}_auto_cvl_ki).state; // Integral gain, adjust as needed
|
||||
float dt = 1.0; // Time step, adjust based on update_interval
|
||||
float kp = id(yambms${yambms_id}_auto_cvl_kp).state; // Proportional gain, adjust as needed
|
||||
float ki = id(yambms${yambms_id}_auto_cvl_ki).state; // Integral gain, adjust as needed
|
||||
float dt = 1.0; // Time step, adjust based on update_interval
|
||||
|
||||
// Check if the common values are available, if not return bulk voltage as CVL
|
||||
if (isnan(cell_count) || isnan(bulk_voltage) ||
|
||||
!id(yambms${yambms_id}_charging_instruction).has_state() || cell_count <= 0) {
|
||||
id(yambms${yambms_id}_var_auto_cvl) = 0.0;
|
||||
return bulk_voltage;
|
||||
}
|
||||
float CVL = bulk_voltage;
|
||||
float CVL_orig = bulk_voltage;
|
||||
|
||||
// Check feature enabled
|
||||
if (!id(yambms${yambms_id}_switch_auto_cvl).state){
|
||||
id(yambms${yambms_id}_var_auto_cvl) = 0.0;
|
||||
prev_integral_bulk = 0.0;
|
||||
prev_integral_avg = 0.0;
|
||||
return bulk_voltage;
|
||||
}
|
||||
std::string charging_instruction = id(yambms${yambms_id}_charging_instruction).state;
|
||||
|
||||
std::string charging_instruction = id(yambms${yambms_id}_charging_instruction).state;
|
||||
float CVL = bulk_voltage;
|
||||
float CVL_orig = bulk_voltage;
|
||||
// +----------------------------------------------------------+
|
||||
// | Gate #1 : Check if the common values are available
|
||||
// +----------------------------------------------------------+
|
||||
if (isnan(cell_count) || isnan(bulk_voltage) || !id(yambms${yambms_id}_charging_instruction).has_state() || cell_count <= 0)
|
||||
{
|
||||
// Reset values
|
||||
id(yambms${yambms_id}_var_auto_cvl) = 0.0;
|
||||
id(yambms${yambms_id}_auto_cvl).publish_state(CVL);
|
||||
id(yambms${yambms_id}_auto_cvl_delta).publish_state(0.0);
|
||||
return;
|
||||
}
|
||||
|
||||
// +-----------------------------------------------+
|
||||
// | Bulk |
|
||||
// +-----------------------------------------------+
|
||||
if ((charging_instruction == "Bulk") && !isnan(balance_delta) && !isnan(max_cell_v)) {
|
||||
float min_CVL = cell_count * id(yambms${yambms_id}_var_cell_min_charge_v); // Minimum CVL
|
||||
float max_CVL = bulk_voltage + id(yambms${yambms_id}_auto_cvl_boost_charge_v).state; // Maximum CVL
|
||||
float cell_bulk_v = (bulk_voltage / cell_count);
|
||||
float max_allowed_voltage = cell_bulk_v + balance_delta;
|
||||
// +----------------------------------------------------------+
|
||||
// | Gate #2 : Check feature enabled
|
||||
// +----------------------------------------------------------+
|
||||
if (!id(yambms${yambms_id}_switch_auto_cvl).state)
|
||||
{
|
||||
// Reset values
|
||||
integral_bulk = 0.0;
|
||||
prev_integral_bulk = 0.0;
|
||||
integral_avg = 0.0;
|
||||
prev_integral_avg = 0.0;
|
||||
id(yambms${yambms_id}_var_auto_cvl) = 0.0;
|
||||
id(yambms${yambms_id}_auto_cvl).publish_state(CVL);
|
||||
id(yambms${yambms_id}_auto_cvl_delta).publish_state(0.0);
|
||||
return;
|
||||
}
|
||||
|
||||
// PI Algorithm
|
||||
float error = cell_bulk_v - max_cell_v;
|
||||
// It's possible for PI control to start before BMS values are available, so don't store non-number values
|
||||
if (isnan(prev_integral_bulk)) {
|
||||
prev_integral_bulk = 0;
|
||||
integral_bulk = 0;
|
||||
}
|
||||
// Check if max cell voltage is in deadband
|
||||
if ((max_cell_v <= max_allowed_voltage) && (max_cell_v >= cell_bulk_v)) {
|
||||
// No integral error within deadband zone
|
||||
} else {
|
||||
integral_bulk = prev_integral_bulk + error * dt;
|
||||
}
|
||||
// Calculate PI output
|
||||
float output = kp * error + ki * integral_bulk;
|
||||
// Update CVL
|
||||
CVL += output;
|
||||
// If CVL is less than lower limit, enforce limit
|
||||
if (CVL < min_CVL) {
|
||||
CVL = min_CVL;
|
||||
}
|
||||
// If CVL is greater than upper limit, enforce limit
|
||||
else if (CVL > max_CVL) {
|
||||
CVL = max_CVL;
|
||||
}
|
||||
else {
|
||||
prev_integral_bulk = integral_bulk;
|
||||
}
|
||||
}
|
||||
// +-----------------------------------------------+
|
||||
// | Float / Stop |
|
||||
// +-----------------------------------------------+
|
||||
else if (((charging_instruction == "Float") || (charging_instruction == "Stop")) &&
|
||||
!isnan(float_voltage) && !isnan(total_voltage)) {
|
||||
float target_v;
|
||||
float min_CVL;
|
||||
if (charging_instruction == "Float") {
|
||||
// Live Auto Float glide target (bulk_voltage -> float_voltage), not the final float_voltage :
|
||||
// Auto CVL must never react ahead of the Auto Float ramp still in progress
|
||||
target_v = float_voltage + id(yambms${yambms_id}_var_auto_float);
|
||||
min_CVL = cell_count * id(yambms${yambms_id}_var_cell_nominal_v);
|
||||
} else { // Stop
|
||||
target_v = cell_count * id(yambms${yambms_id}_var_cell_nominal_v);
|
||||
min_CVL = cell_count * id(yambms${yambms_id}_var_cell_max_discharge_v);
|
||||
}
|
||||
float max_CVL = target_v; // Never correct above target
|
||||
float average_cell_v = (total_voltage / cell_count);
|
||||
float target_cell_v = (target_v / cell_count);
|
||||
// +----------------------------------------------------------+
|
||||
// | Reset PI state when crossing the Bulk <-> Float/Stop boundary
|
||||
// | (Float <-> Stop keeps its shared state on purpose : both track average_cell_v)
|
||||
// +----------------------------------------------------------+
|
||||
bool is_bulk_phase = (charging_instruction == "Bulk");
|
||||
static bool prev_is_bulk_phase = is_bulk_phase;
|
||||
if (is_bulk_phase != prev_is_bulk_phase)
|
||||
{
|
||||
integral_bulk = 0.0;
|
||||
prev_integral_bulk = 0.0;
|
||||
integral_avg = 0.0;
|
||||
prev_integral_avg = 0.0;
|
||||
prev_is_bulk_phase = is_bulk_phase;
|
||||
}
|
||||
|
||||
CVL = target_v;
|
||||
CVL_orig = target_v;
|
||||
// +----------------------------------------------------------+
|
||||
// | Auto CVL - Bulk
|
||||
// +----------------------------------------------------------+
|
||||
if ((charging_instruction == "Bulk") && !isnan(balance_delta) && !isnan(max_cell_v))
|
||||
{
|
||||
float min_CVL = cell_count * id(yambms${yambms_id}_var_cell_min_charge_v); // Minimum CVL
|
||||
float max_CVL = bulk_voltage + id(yambms${yambms_id}_auto_cvl_boost_charge_v).state; // Maximum CVL
|
||||
float cell_bulk_v = (bulk_voltage / cell_count);
|
||||
float max_allowed_voltage = cell_bulk_v + balance_delta;
|
||||
|
||||
// PI Algorithm : no deadband, react as soon as average_cell_v exceeds target_cell_v
|
||||
float error = target_cell_v - average_cell_v;
|
||||
if (isnan(prev_integral_avg)) {
|
||||
prev_integral_avg = 0;
|
||||
integral_avg = 0;
|
||||
}
|
||||
if (average_cell_v <= target_cell_v) {
|
||||
// No integral error, nothing to compensate
|
||||
} else {
|
||||
integral_avg = prev_integral_avg + error * dt;
|
||||
}
|
||||
float output = kp * error + ki * integral_avg;
|
||||
CVL += output;
|
||||
if (CVL < min_CVL) {
|
||||
CVL = min_CVL;
|
||||
}
|
||||
else if (CVL > max_CVL) {
|
||||
CVL = max_CVL;
|
||||
}
|
||||
else {
|
||||
prev_integral_avg = integral_avg;
|
||||
}
|
||||
}
|
||||
// PI Algorithm
|
||||
float error = cell_bulk_v - max_cell_v;
|
||||
// It's possible for PI control to start before BMS values are available, so don't store non-number values
|
||||
if (isnan(prev_integral_bulk))
|
||||
{
|
||||
prev_integral_bulk = 0;
|
||||
integral_bulk = 0;
|
||||
}
|
||||
// Check if max cell voltage is in deadband
|
||||
if ((max_cell_v <= max_allowed_voltage) && (max_cell_v >= cell_bulk_v))
|
||||
{
|
||||
// No integral error within deadband zone
|
||||
}
|
||||
else
|
||||
{
|
||||
integral_bulk = prev_integral_bulk + error * dt;
|
||||
}
|
||||
// Calculate PI output
|
||||
float output = kp * error + ki * integral_bulk;
|
||||
// Update CVL
|
||||
CVL += output;
|
||||
// If CVL is less than lower limit, enforce limit
|
||||
if (CVL < min_CVL)
|
||||
{
|
||||
CVL = min_CVL;
|
||||
}
|
||||
// If CVL is greater than upper limit, enforce limit
|
||||
else if (CVL > max_CVL)
|
||||
{
|
||||
CVL = max_CVL;
|
||||
}
|
||||
else
|
||||
{
|
||||
prev_integral_bulk = integral_bulk;
|
||||
}
|
||||
}
|
||||
|
||||
id(yambms${yambms_id}_var_auto_cvl) = CVL - CVL_orig;
|
||||
return CVL - CVL_orig;
|
||||
// +----------------------------------------------------------+
|
||||
// | Auto CVL - Float / Stop
|
||||
// +----------------------------------------------------------+
|
||||
else if (((charging_instruction == "Float") || (charging_instruction == "Stop")) && !isnan(float_voltage) && !isnan(total_voltage))
|
||||
{
|
||||
float target_v;
|
||||
float min_CVL;
|
||||
if (charging_instruction == "Float")
|
||||
{
|
||||
// Live Auto Float glide target (bulk_voltage -> float_voltage), not the final float_voltage :
|
||||
// Auto CVL must never react ahead of the Auto Float ramp still in progress
|
||||
target_v = float_voltage + id(yambms${yambms_id}_var_auto_float);
|
||||
// Floor derived from `Rebulk V.` : Auto CVL must never be able to drag the pack down
|
||||
// to the rebulk threshold, or it would trigger its own rebulk and loop
|
||||
float rebulk_v = id(yambms${yambms_id}_rebulk_voltage).state;
|
||||
min_CVL = isnan(rebulk_v) ? (cell_count * id(yambms${yambms_id}_var_cell_nominal_v))
|
||||
: (rebulk_v + ${auto_cvl_rebulk_margin_v});
|
||||
}
|
||||
else // Stop
|
||||
{
|
||||
target_v = cell_count * id(yambms${yambms_id}_var_cell_nominal_v);
|
||||
min_CVL = cell_count * id(yambms${yambms_id}_var_cell_max_discharge_v);
|
||||
}
|
||||
|
||||
// A target already at or below the floor leaves no room to correct : clamp to the
|
||||
// target itself so Auto CVL stays neutral instead of pushing the voltage back up
|
||||
if (min_CVL > target_v) min_CVL = target_v;
|
||||
|
||||
float max_CVL = target_v; // Never correct above target
|
||||
float average_cell_v = (total_voltage / cell_count);
|
||||
float target_cell_v = (target_v / cell_count);
|
||||
|
||||
CVL = target_v;
|
||||
CVL_orig = target_v;
|
||||
|
||||
// PI Algorithm : no deadband, react as soon as average_cell_v exceeds target_cell_v
|
||||
float error = target_cell_v - average_cell_v;
|
||||
if (isnan(prev_integral_avg))
|
||||
{
|
||||
prev_integral_avg = 0;
|
||||
}
|
||||
|
||||
// Accumulate on any error sign, but never let the integral wind up positive : max_CVL
|
||||
// already blocks any upward correction, so a lingering positive integral would only
|
||||
// delay the reaction to the next real overshoot instead of protecting against it
|
||||
integral_avg = prev_integral_avg + error * dt;
|
||||
if (integral_avg > 0) integral_avg = 0;
|
||||
|
||||
// Anti-windup : cap the integral at the correction min_CVL can actually deliver.
|
||||
// Without it, a pack that stays above target while the CVL has no effect (inverter
|
||||
// substituting its own target, e.g. Deye in ToU mode) winds the integral down without
|
||||
// bound, and the CVL stays pinned to the floor long after the cause is gone.
|
||||
if (ki > 0)
|
||||
{
|
||||
float integral_min = -(target_v - min_CVL) / ki;
|
||||
if (integral_avg < integral_min) integral_avg = integral_min;
|
||||
}
|
||||
float output = kp * error + ki * integral_avg;
|
||||
CVL += output;
|
||||
if (CVL < min_CVL)
|
||||
{
|
||||
CVL = min_CVL;
|
||||
}
|
||||
else if (CVL > max_CVL)
|
||||
{
|
||||
CVL = max_CVL;
|
||||
}
|
||||
prev_integral_avg = integral_avg;
|
||||
}
|
||||
|
||||
float auto_cvl_delta = CVL - CVL_orig;
|
||||
auto_cvl_delta = roundf(auto_cvl_delta * 10.0f) / 10.0f;
|
||||
id(yambms${yambms_id}_var_auto_cvl) = auto_cvl_delta;
|
||||
|
||||
// Publish the sensor
|
||||
id(yambms${yambms_id}_auto_cvl).publish_state(CVL);
|
||||
id(yambms${yambms_id}_auto_cvl_delta).publish_state(auto_cvl_delta);
|
||||
Reference in new issue