Updated YamBMS multi-node modbus YAMLs

This commit is contained in:
Sleeper85 committed 2025-08-02 11:02:28 +02:00
1 parent 0829fc64b9
commit 5ddf954d0f
12 files changed
+66 -62

No files matched your search

@@ -1,5 +1,5 @@
# Updated : 2025.07.28
# Version : 1.1.1
# Updated : 2025.08.02
# Version : 1.1.2
# GitHub : https://github.com/Sleeper85/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -23,16 +23,10 @@
################################################################################
substitutions:
modbus_update_interval: '5s' # frequency with which BMS/Shunt modbus servers are queried
modbus_baud_rate: '19200' # 9600 / 19200 / 115200
modbus_command_throttle: '0ms' # minimum time in between 2 requests to the device
modbus_send_wait_time: '250ms' # time in milliseconds before the next ModBUS command is sent if an answer from a previous command is pending
packages:
modbus: !include
file: packages/base/device_modbus.yaml
file: packages/board/board_options_itf_modbus.yaml
vars:
modbus_role: 'client' # client / server
modbus_uart_id: 'uart_esp_1' # RS485 board
@@ -1,5 +1,5 @@
# Updated : 2025.07.28
# Version : 1.1.1
# Updated : 2025.08.02
# Version : 1.1.2
# GitHub : https://github.com/Sleeper85/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -24,15 +24,13 @@
################################################################################
substitutions:
modbus_update_interval: '5s' # frequency with which BMS/Shunt modbus servers are queried
modbus_baud_rate: '19200' # 9600 / 19200 / 115200
modbus_command_throttle: '0ms' # minimum time in between 2 requests to the device
modbus_send_wait_time: '250ms' # time in milliseconds before the next ModBUS command is sent if an answer from a previous command is pending
friendly_name : 'YamBMS Modbus Server 1' # Prefix added in front of the `entity display name`, also used to classify them.
hostname: 'yambms-modbus-server-1' # Name of your ESPHome node registered on the IP network (DNS name, must be unique) and prefix added in front of the `entity id`.
packages:
modbus: !include
file: packages/base/device_modbus.yaml
file: packages/board/board_options_itf_modbus.yaml
vars:
modbus_role: 'server' # client / server
modbus_uart_id: 'uart_esp_1' # RS485 board
@@ -1,5 +1,5 @@
# Updated : 2025.07.28
# Version : 1.1.1
# Updated : 2025.08.02
# Version : 1.1.2
# GitHub : https://github.com/Sleeper85/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -24,15 +24,13 @@
################################################################################
substitutions:
modbus_update_interval: '5s' # frequency with which BMS/Shunt modbus servers are queried
modbus_baud_rate: '19200' # 9600 / 19200 / 115200
modbus_command_throttle: '0ms' # minimum time in between 2 requests to the device
modbus_send_wait_time: '250ms' # time in milliseconds before the next ModBUS command is sent if an answer from a previous command is pending
friendly_name : 'YamBMS Modbus Server 2' # Prefix added in front of the `entity display name`, also used to classify them.
hostname: 'yambms-modbus-server-2' # Name of your ESPHome node registered on the IP network (DNS name, must be unique) and prefix added in front of the `entity id`.
packages:
modbus: !include
file: packages/base/device_modbus.yaml
file: packages/board/board_options_itf_modbus.yaml
vars:
modbus_role: 'server' # client / server
modbus_uart_id: 'uart_esp_1' # RS485 board
@@ -1,5 +1,5 @@
# Updated : 2025.07.28
# Version : 1.1.1
# Updated : 2025.08.02
# Version : 1.1.2
# GitHub : https://github.com/Sleeper85/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -23,12 +23,6 @@
################################################################################
substitutions:
modbus_update_interval: '5s' # frequency with which BMS/Shunt modbus servers are queried
modbus_baud_rate: '19200' # 9600 / 19200 / 115200
modbus_command_throttle: '0ms' # minimum time in between 2 requests to the device
modbus_send_wait_time: '250ms' # time in milliseconds before the next ModBUS command is sent if an answer from a previous command is pending
packages:
yambms_modbus_client:
@@ -37,7 +31,7 @@ packages:
refresh: 0s
files:
# Modbus client
- path: 'packages/base/device_modbus.yaml'
- path: 'packages/board/board_options_itf_modbus.yaml'
vars:
modbus_role: 'client' # client / server
modbus_uart_id: 'uart_esp_1' # RS485 board
@@ -1,5 +1,5 @@
# Updated : 2025.07.28
# Version : 1.1.1
# Updated : 2025.08.02
# Version : 1.1.2
# GitHub : https://github.com/Sleeper85/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -24,10 +24,8 @@
################################################################################
substitutions:
modbus_update_interval: '5s' # frequency with which BMS/Shunt modbus servers are queried
modbus_baud_rate: '19200' # 9600 / 19200 / 115200
modbus_command_throttle: '0ms' # minimum time in between 2 requests to the device
modbus_send_wait_time: '250ms' # time in milliseconds before the next ModBUS command is sent if an answer from a previous command is pending
friendly_name : 'YamBMS Modbus Server 1' # Prefix added in front of the `entity display name`, also used to classify them.
hostname: 'yambms-modbus-server-1' # Name of your ESPHome node registered on the IP network (DNS name, must be unique) and prefix added in front of the `entity id`.
packages:
@@ -37,7 +35,7 @@ packages:
refresh: 0s
files:
# Modbus server
- path: 'packages/base/device_modbus.yaml'
- path: 'packages/board/board_options_itf_modbus.yaml'
vars:
modbus_role: 'server' # client / server
modbus_uart_id: 'uart_esp_1' # RS485 board
@@ -1,5 +1,5 @@
# Updated : 2025.07.28
# Version : 1.1.1
# Updated : 2025.08.02
# Version : 1.1.2
# GitHub : https://github.com/Sleeper85/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -24,10 +24,8 @@
################################################################################
substitutions:
modbus_update_interval: '5s' # frequency with which BMS/Shunt modbus servers are queried
modbus_baud_rate: '19200' # 9600 / 19200 / 115200
modbus_command_throttle: '0ms' # minimum time in between 2 requests to the device
modbus_send_wait_time: '250ms' # time in milliseconds before the next ModBUS command is sent if an answer from a previous command is pending
friendly_name : 'YamBMS Modbus Server 2' # Prefix added in front of the `entity display name`, also used to classify them.
hostname: 'yambms-modbus-server-2' # Name of your ESPHome node registered on the IP network (DNS name, must be unique) and prefix added in front of the `entity id`.
packages:
@@ -37,7 +35,7 @@ packages:
refresh: 0s
files:
# Modbus server
- path: 'packages/base/device_modbus.yaml'
- path: 'packages/board/board_options_itf_modbus.yaml'
vars:
modbus_role: 'server' # client / server
modbus_uart_id: 'uart_esp_1' # RS485 board