Add options to restrict max. charge and discharge current
This adds 'yambms_max_inverter_charge_current' and 'yambms_max_inverter_discharge_current' substitutions. They are used to restrict the range of the charge/discharge current for easier control when the battery currents are much higher than the inverter currents.
This commit is contained in:
1 parent
17b7500f0c
commit
77f657415a
21 files changed
+162
-45
No files matched your search
@@ -1,5 +1,5 @@
|
||||
# Updated : 2025.06.26
|
||||
# Version : 1.5.7
|
||||
# Updated : 2025.06.29
|
||||
# Version : 1.5.8
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -98,6 +98,12 @@ substitutions:
|
||||
yambms_eoc_timer: '30'
|
||||
# Time in seconds during which the end of charge conditions must be respected (cut-off + cells not equalizing)
|
||||
yambms_cutoff_timer: '60'
|
||||
# Max. charge current : corresponds to the maximum charge current which may be requested by YamBMS.
|
||||
# The current requested will be proportional to the BMS count without ever exceeding this value.
|
||||
yambms_max_requested_charge_current: '300' # in Ampere
|
||||
# Max. discharge current : corresponds to the maximum discharge current which may be requested by YamBMS.
|
||||
# The current requested will be proportional to the BMS count without ever exceeding this value.
|
||||
yambms_max_requested_discharge_current: '300' # in Ampere
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
|
||||