From 9e8dff09e50392a8076c44effced2a8ace10c7b2 Mon Sep 17 00:00:00 2001 From: Sleeper85 Date: Tue, 10 Nov 2026 13:20:24 +0100 Subject: [PATCH] Docs: Add inferred balancing to the 1.8.1 upgrade guide EG4 LL V2, Seplos V1/V2, Seplos V3 and JK RS485 DISPLAY now infer their balancing state. It changes when the charge ends without any validation error, so it belongs in the biggest changes of the upgrade guide. --- .../README/changelog/Changelog_upgrade_to_YamBMS_1.8.1.md | 5 +++++ 1 file changed, 5 insertions(+) diff --git a/documents/README/changelog/Changelog_upgrade_to_YamBMS_1.8.1.md b/documents/README/changelog/Changelog_upgrade_to_YamBMS_1.8.1.md index a1bf6a9..8d33499 100644 --- a/documents/README/changelog/Changelog_upgrade_to_YamBMS_1.8.1.md +++ b/documents/README/changelog/Changelog_upgrade_to_YamBMS_1.8.1.md @@ -28,6 +28,11 @@ have made the changes below. CAN and RS485 links can run at the same time: keep both blocks, each link with its own `canbus_id` or `rs485_id`. The dashboard shows up to 3 CAN links and 3 RS485 links. If you only use RS485, comment out the CAN block. +- **Balancing inferred:** EG4 LL V2, Seplos V1/V2, Seplos V3 and JK RS485 DISPLAY do not report + balancing, and YamBMS now infers it from the cell spread. While a pack is seen as balancing, the + charge only ends when the spread closes or the EOC timer expires, and the SoC stays at 98% until + then. Set `bms_balance_trigger_voltage` to your BMS's actual setting and keep `EOC timer enabled` + ON. See [Fake Equalizing](Changelog_Fake_Equalizing.md). ## How to update from 1.7.0 or 1.8.0