Improved SEPLOS V1 V2 examples
This commit is contained in:
1 parent
68a7a6aac6
commit
a1a2ce9e19
4 files changed
+60
-37
No files matched your search
@@ -1,5 +1,5 @@
|
||||
# Updated : 2025.07.27
|
||||
# Version : 1.1.1
|
||||
# Updated : 2025.11.15
|
||||
# Version : 1.1.2
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -25,20 +25,15 @@
|
||||
|
||||
packages:
|
||||
|
||||
seplos_modbus1: !include
|
||||
seplos_modbus: !include
|
||||
file: packages/bms/bms_combine_SEPLOS_V1_V2_RS485_modbus.yaml
|
||||
vars:
|
||||
seplos_modbus_id: 'seplos_modbus1'
|
||||
seplos_modbus_uart_id: 'uart_esp_1'
|
||||
seplos_modbus_baud_rate: '9600' # 9600 / 19200 ; please set the baudrate of your Seplos BMS model here
|
||||
seplos_modbus_rx_timeout: '150ms'
|
||||
|
||||
bms1: !include
|
||||
file: packages/bms/bms_combine_SEPLOS_V1_V2_RS485_bms_full.yaml
|
||||
vars:
|
||||
# Seplos modbus ID
|
||||
seplos_modbus_id: 'seplos_modbus1'
|
||||
# BMS vars
|
||||
bms_id: '1' # must be a number
|
||||
bms_name: 'BMS 1'
|
||||
bms_address: '0x01' # BMS 1 DIP switch
|
||||
@@ -55,14 +50,26 @@ packages:
|
||||
bms2: !include
|
||||
file: packages/bms/bms_combine_SEPLOS_V1_V2_RS485_bms_full.yaml
|
||||
vars:
|
||||
# Seplos modbus ID
|
||||
seplos_modbus_id: 'seplos_modbus1'
|
||||
# BMS vars
|
||||
bms_id: '2' # must be a number
|
||||
bms_name: 'BMS 2'
|
||||
bms_address: '0x02' # BMS 2 DIP switch
|
||||
bms_protocol_version: '0x20' # Known protocol versions: 0x20 (Seplos), 0x26 (Boqiang)
|
||||
bms_uart_id: uart_esp_2
|
||||
# Required settings cannot be retrieved from BMS
|
||||
# These values must match your BMS settings
|
||||
# LFP values example
|
||||
bms_max_charge_current: '100' # A. Used to calculate maximum charge current
|
||||
bms_max_discharge_current: '100' # A. Used to calculate maximum discharge current
|
||||
bms_cell_ovp: '3.650' # V. Used by 'Auto CCL' functions
|
||||
bms_cell_uvp: '2.800' # V. Used by 'Auto DCL' functions and to calculate maximum discharge voltage
|
||||
bms_balance_trigger_voltage: '0.010' # V. Used by 'Auto CVL' functions
|
||||
|
||||
bms3: !include
|
||||
file: packages/bms/bms_combine_SEPLOS_V1_V2_RS485_bms_full.yaml
|
||||
vars:
|
||||
bms_id: '3' # must be a number
|
||||
bms_name: 'BMS 3'
|
||||
bms_address: '0x03' # BMS 2 DIP switch
|
||||
bms_protocol_version: '0x20' # Known protocol versions: 0x20 (Seplos), 0x26 (Boqiang)
|
||||
# Required settings cannot be retrieved from BMS
|
||||
# These values must match your BMS settings
|
||||
# LFP values example
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2025.07.27
|
||||
# Version : 1.1.1
|
||||
# Updated : 2025.11.15
|
||||
# Version : 1.1.2
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -30,19 +30,14 @@ packages:
|
||||
ref: main
|
||||
refresh: 0s
|
||||
files:
|
||||
# Seplos Modbus 1
|
||||
# Seplos Modbus
|
||||
- path: 'packages/bms/bms_combine_SEPLOS_V1_V2_RS485_modbus.yaml'
|
||||
vars:
|
||||
seplos_modbus_id: 'seplos_modbus1'
|
||||
seplos_modbus_uart_id: 'uart_esp_1'
|
||||
seplos_modbus_baud_rate: '9600' # 9600 / 19200 ; please set the baudrate of your Seplos BMS model here
|
||||
seplos_modbus_rx_timeout: '150ms'
|
||||
# BMS 1
|
||||
- path: 'packages/bms/bms_combine_SEPLOS_V1_V2_RS485_bms_full.yaml'
|
||||
vars:
|
||||
# Seplos modbus ID
|
||||
seplos_modbus_id: 'seplos_modbus1'
|
||||
# BMS vars
|
||||
bms_id: '1' # must be a number
|
||||
bms_name: 'BMS 1'
|
||||
bms_address: '0x01' # BMS 1 DIP switch
|
||||
@@ -58,14 +53,25 @@ packages:
|
||||
# BMS 2
|
||||
- path: 'packages/bms/bms_combine_SEPLOS_V1_V2_RS485_bms_full.yaml'
|
||||
vars:
|
||||
# Seplos modbus ID
|
||||
seplos_modbus_id: 'seplos_modbus1'
|
||||
# BMS vars
|
||||
bms_id: '2' # must be a number
|
||||
bms_name: 'BMS 2'
|
||||
bms_address: '0x02' # BMS 2 DIP switch
|
||||
bms_protocol_version: '0x20' # Known protocol versions: 0x20 (Seplos), 0x26 (Boqiang)
|
||||
bms_uart_id: uart_esp_2
|
||||
# Required settings cannot be retrieved from BMS
|
||||
# These values must match your BMS settings
|
||||
# LFP values example
|
||||
bms_max_charge_current: '100' # A. Used to calculate maximum charge current
|
||||
bms_max_discharge_current: '100' # A. Used to calculate maximum discharge current
|
||||
bms_cell_ovp: '3.650' # V. Used by 'Auto CCL' functions
|
||||
bms_cell_uvp: '2.800' # V. Used by 'Auto DCL' functions and to calculate maximum discharge voltage
|
||||
bms_balance_trigger_voltage: '0.010' # V. Used by 'Auto CVL' functions
|
||||
# BMS 3
|
||||
- path: 'packages/bms/bms_combine_SEPLOS_V1_V2_RS485_bms_full.yaml'
|
||||
vars:
|
||||
bms_id: '3' # must be a number
|
||||
bms_name: 'BMS 3'
|
||||
bms_address: '0x03' # BMS 2 DIP switch
|
||||
bms_protocol_version: '0x20' # Known protocol versions: 0x20 (Seplos), 0x26 (Boqiang)
|
||||
# Required settings cannot be retrieved from BMS
|
||||
# These values must match your BMS settings
|
||||
# LFP values example
|
||||
|
||||
Reference in new issue
Block a user