Improved SEPLOS V1 V2 examples

This commit is contained in:
Sleeper85 committed 2025-11-15 00:19:38 +01:00
1 parent 68a7a6aac6
commit a1a2ce9e19
4 files changed
+60 -37

No files matched your search

@@ -1,5 +1,5 @@
# Updated : 2025.07.27
# Version : 1.1.1
# Updated : 2025.11.15
# Version : 1.1.2
# GitHub : https://github.com/Sleeper85/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -25,20 +25,15 @@
packages:
seplos_modbus1: !include
seplos_modbus: !include
file: packages/bms/bms_combine_SEPLOS_V1_V2_RS485_modbus.yaml
vars:
seplos_modbus_id: 'seplos_modbus1'
seplos_modbus_uart_id: 'uart_esp_1'
seplos_modbus_baud_rate: '9600' # 9600 / 19200 ; please set the baudrate of your Seplos BMS model here
seplos_modbus_rx_timeout: '150ms'
bms1: !include
file: packages/bms/bms_combine_SEPLOS_V1_V2_RS485_bms_full.yaml
vars:
# Seplos modbus ID
seplos_modbus_id: 'seplos_modbus1'
# BMS vars
bms_id: '1' # must be a number
bms_name: 'BMS 1'
bms_address: '0x01' # BMS 1 DIP switch
@@ -55,14 +50,26 @@ packages:
bms2: !include
file: packages/bms/bms_combine_SEPLOS_V1_V2_RS485_bms_full.yaml
vars:
# Seplos modbus ID
seplos_modbus_id: 'seplos_modbus1'
# BMS vars
bms_id: '2' # must be a number
bms_name: 'BMS 2'
bms_address: '0x02' # BMS 2 DIP switch
bms_protocol_version: '0x20' # Known protocol versions: 0x20 (Seplos), 0x26 (Boqiang)
bms_uart_id: uart_esp_2
# Required settings cannot be retrieved from BMS
# These values ​​must match your BMS settings
# LFP values example
bms_max_charge_current: '100' # A. Used to calculate maximum charge current
bms_max_discharge_current: '100' # A. Used to calculate maximum discharge current
bms_cell_ovp: '3.650' # V. Used by 'Auto CCL' functions
bms_cell_uvp: '2.800' # V. Used by 'Auto DCL' functions and to calculate maximum discharge voltage
bms_balance_trigger_voltage: '0.010' # V. Used by 'Auto CVL' functions
bms3: !include
file: packages/bms/bms_combine_SEPLOS_V1_V2_RS485_bms_full.yaml
vars:
bms_id: '3' # must be a number
bms_name: 'BMS 3'
bms_address: '0x03' # BMS 2 DIP switch
bms_protocol_version: '0x20' # Known protocol versions: 0x20 (Seplos), 0x26 (Boqiang)
# Required settings cannot be retrieved from BMS
# These values ​​must match your BMS settings
# LFP values example
@@ -1,5 +1,5 @@
# Updated : 2025.07.27
# Version : 1.1.1
# Updated : 2025.11.15
# Version : 1.1.2
# GitHub : https://github.com/Sleeper85/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -30,19 +30,14 @@ packages:
ref: main
refresh: 0s
files:
# Seplos Modbus 1
# Seplos Modbus
- path: 'packages/bms/bms_combine_SEPLOS_V1_V2_RS485_modbus.yaml'
vars:
seplos_modbus_id: 'seplos_modbus1'
seplos_modbus_uart_id: 'uart_esp_1'
seplos_modbus_baud_rate: '9600' # 9600 / 19200 ; please set the baudrate of your Seplos BMS model here
seplos_modbus_rx_timeout: '150ms'
# BMS 1
- path: 'packages/bms/bms_combine_SEPLOS_V1_V2_RS485_bms_full.yaml'
vars:
# Seplos modbus ID
seplos_modbus_id: 'seplos_modbus1'
# BMS vars
bms_id: '1' # must be a number
bms_name: 'BMS 1'
bms_address: '0x01' # BMS 1 DIP switch
@@ -58,14 +53,25 @@ packages:
# BMS 2
- path: 'packages/bms/bms_combine_SEPLOS_V1_V2_RS485_bms_full.yaml'
vars:
# Seplos modbus ID
seplos_modbus_id: 'seplos_modbus1'
# BMS vars
bms_id: '2' # must be a number
bms_name: 'BMS 2'
bms_address: '0x02' # BMS 2 DIP switch
bms_protocol_version: '0x20' # Known protocol versions: 0x20 (Seplos), 0x26 (Boqiang)
bms_uart_id: uart_esp_2
# Required settings cannot be retrieved from BMS
# These values ​​must match your BMS settings
# LFP values example
bms_max_charge_current: '100' # A. Used to calculate maximum charge current
bms_max_discharge_current: '100' # A. Used to calculate maximum discharge current
bms_cell_ovp: '3.650' # V. Used by 'Auto CCL' functions
bms_cell_uvp: '2.800' # V. Used by 'Auto DCL' functions and to calculate maximum discharge voltage
bms_balance_trigger_voltage: '0.010' # V. Used by 'Auto CVL' functions
# BMS 3
- path: 'packages/bms/bms_combine_SEPLOS_V1_V2_RS485_bms_full.yaml'
vars:
bms_id: '3' # must be a number
bms_name: 'BMS 3'
bms_address: '0x03' # BMS 2 DIP switch
bms_protocol_version: '0x20' # Known protocol versions: 0x20 (Seplos), 0x26 (Boqiang)
# Required settings cannot be retrieved from BMS
# These values ​​must match your BMS settings
# LFP values example