Reorganization of variables
This commit is contained in:
1 parent
de6d37e308
commit
b2c5f65478
26 files changed
+270
-648
No files matched your search
@@ -1,4 +1,4 @@
|
||||
# Updated : 2025.11.26
|
||||
# Updated : 2025.12.09
|
||||
# Version : 1.6.0
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
@@ -96,45 +96,24 @@ substitutions:
|
||||
# Max. discharge current : corresponds to the maximum discharge current which may be requested by YamBMS.
|
||||
# The current requested will be proportional to the BMS count without ever exceeding this value.
|
||||
yambms_max_requested_discharge_current: '300' # in Ampere
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
shunt_combine_interval: '1s' # frequency at which Shunt data is combined in YamBMS
|
||||
# +--------------------------------------+
|
||||
# | BMS Settings |
|
||||
# +--------------------------------------+
|
||||
bms_update_interval: '3s' # frequency at which BMS data is refreshed, going below '3s' can cause problems
|
||||
bms_combine_interval: '1s' # frequency at which BMS data is combined in YamBMS
|
||||
bms_cutoff_timer: '50s' # time during which the end of charge conditions must be respected (cut-off + cells not equalizing)
|
||||
|
||||
|
||||
|
||||
globals:
|
||||
# +-------------------------------------------------------------------------
|
||||
# | Temperature-based current limitation
|
||||
# | Can be disabled via the switch "Temperature-based current limitation"
|
||||
# | This factor is applied to the battery capacity (Ah), not the current
|
||||
# | maximum charge/discharge current. For example : 280Ah x 0.5 = 140A
|
||||
# +-------------------------------------------------------------------------
|
||||
# | Temperature-based charging rate
|
||||
# +-------------------------------------------------------------------------
|
||||
# The default 'initial_value' rate values can be modified.
|
||||
- id: ${yambms_id}_var_charging_rate
|
||||
type: float[10]
|
||||
restore_value: no
|
||||
# Temp.°C Rate : 0, 5, 10, 15, 20, 25, 45, 50, 55, 60
|
||||
initial_value: '{0.05, 0.12, 0.3, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.0}'
|
||||
# +-------------------------------------------------------------------------
|
||||
# | Temperature-based discharging rate
|
||||
# +-------------------------------------------------------------------------
|
||||
# The default 'initial_value' rate values can be modified.
|
||||
- id: ${yambms_id}_var_discharging_rate
|
||||
type: float[10]
|
||||
restore_value: no
|
||||
# Temp.°C Rate : -30, -20, -10, -5, 0, 5, 45, 50, 55, 60
|
||||
initial_value: '{0.0, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.0}'
|
||||
|
||||
# Charge rate >= temp. °C : 0, 5, 10, 15, 20, 25, 45, 50, 55, 60
|
||||
yambms_charging_rate_table: '{0.05, 0.12, 0.3, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.0}'
|
||||
# Discharge rate <= temp. °C : -30, -20, -10, -5, 0, 5, 45, 50, 55, 60
|
||||
yambms_discharging_rate_table: '{0.0, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.0}'
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
# +--------------------------------------+
|
||||
# | BMS Settings |
|
||||
# +--------------------------------------+
|
||||
bms_update_interval: '3s' # frequency at which BMS data is refreshed, going below '3s' can cause problems
|
||||
|
||||
|
||||
# +--------------------------------------+
|
||||
|
||||
Reference in new issue
Block a user