From b7bb2e93ea5559c563b366ef0773d875ea675bae Mon Sep 17 00:00:00 2001 From: Sleeper85 Date: Tue, 25 Aug 2026 11:54:41 +0200 Subject: [PATCH] Moved Auto CCL Current Taper section --- documents/README/YamBMS_functions.md | 33 ++++++++++++++-------------- 1 file changed, 16 insertions(+), 17 deletions(-) diff --git a/documents/README/YamBMS_functions.md b/documents/README/YamBMS_functions.md index 9652d15..5bcc9b9 100644 --- a/documents/README/YamBMS_functions.md +++ b/documents/README/YamBMS_functions.md @@ -429,23 +429,6 @@ Afterwards the battery is then discharged, however `Requested Charge Current (CC `Auto SoC Limit` - `Auto SoC Hysteresis` = `80%` - `5%` = `75%`. Without this, the `SoC` would oscillate between `79%` and `80%`, stressing components unnecessary. - -## Inverter Heartbeat Monitoring - -![Image](../../images/YamBMS_Inverter_Heartbeat.png "YamBMS_Inverter_Heartbeat") - -This feature allows you to monitor the heartbeat of your inverter (time between two ACK 0x305). This is useful for troubleshooting purposes and should not remain enabled continuously. - -This heartbeat must be regular and depends on the selected `CAN protocol` and the behavior of the inverter. If the heartbeat is not regular this can show a problem on the inverter side or an overloaded ESP32. - -The `Deye` inverter sends an ACK `0x305` in response to the reception of a CAN frame `0x356`. Knowing that CAN frames are sent every `100ms` and that the CAN protocol `PYLON 1.2` has 6 CAN frames, the heartbeat of the `Deye` inverter is `600ms`. - -> [!IMPORTANT] -> Every `2h` Deye takes more than `3s` to respond and more than `5s` at midnight. -> This is what the `CANBUS Status` looks like when the `canbus_link_timer` is set to `3s`. - -![Image](../../images/YamBMS_CANBUS_Status.png "YamBMS_CANBUS_Status") - ## Auto CCL Current Taper Optional Auto CCL package (`yambms_auto_ccl_current_taper.yaml`). @@ -495,6 +478,22 @@ Notes: - If you taper toward near zero, you may also need a higher cut-off voltage or a longer cut-off timer to avoid an early `Cut-Off`. - Pair with `Charger Offset V.` when the inverter undershoots bulk. +## Inverter Heartbeat Monitoring + +![Image](../../images/YamBMS_Inverter_Heartbeat.png "YamBMS_Inverter_Heartbeat") + +This feature allows you to monitor the heartbeat of your inverter (time between two ACK 0x305). This is useful for troubleshooting purposes and should not remain enabled continuously. + +This heartbeat must be regular and depends on the selected `CAN protocol` and the behavior of the inverter. If the heartbeat is not regular this can show a problem on the inverter side or an overloaded ESP32. + +The `Deye` inverter sends an ACK `0x305` in response to the reception of a CAN frame `0x356`. Knowing that CAN frames are sent every `100ms` and that the CAN protocol `PYLON 1.2` has 6 CAN frames, the heartbeat of the `Deye` inverter is `600ms`. + +> [!IMPORTANT] +> Every `2h` Deye takes more than `3s` to respond and more than `5s` at midnight. +> This is what the `CANBUS Status` looks like when the `canbus_link_timer` is set to `3s`. + +![Image](../../images/YamBMS_CANBUS_Status.png "YamBMS_CANBUS_Status") + ## Diagnostic Useful information for troubleshooting.