diff --git a/documents/README/Board_LilyGo_T-Connect.md b/documents/README/Board_LilyGo_T-Connect.md index 2ad867d..1c9b321 100644 --- a/documents/README/Board_LilyGo_T-Connect.md +++ b/documents/README/Board_LilyGo_T-Connect.md @@ -132,12 +132,11 @@ To connect an RS485 device to any of the configured RS485 ports: | GND | DG : Data/Device Ground (optional but recommended) | **Wiring Steps:** -1. Ensure the port is configured for RS485 mode using the onboard jumpers -2. Identify the A and B wires from your RS485 device (often labeled as D+/D- or A/B) -3. Connect the **A wire (D+)** to the **L pin** of the RS485 port -4. Connect the **B wire (D-)** to the **H pin** of the RS485 port -5. **Connect the ground wire** to the **DG pin** for common reference (highly recommended) -6. If using **shielded cable**, connect the shield to the **SG pin** (recommended for noisy environments) +1. Identify the A and B wires from your RS485 device (often labeled as D+/D- or A/B) +2. Connect the **A wire (D+)** to the **L pin** of the RS485 port +3. Connect the **B wire (D-)** to the **H pin** of the RS485 port +4. **Connect the ground wire** to the **DG pin** for common reference (highly recommended) +5. If using **shielded cable**, connect the shield to the **SG pin** (recommended for noisy environments) **Ground Connection Best Practices:** - **Always connect DG (Data Ground)** to provide a common reference between devices @@ -169,12 +168,11 @@ To connect a CAN bus device to the CAN port: | GND | DG : Data/Device Ground (optional but recommended) | **Wiring Steps:** -1. Ensure the port is configured for CAN mode using the onboard jumpers -2. Identify the CAN H and CAN L wires from your CAN device -3. Connect the **CAN H wire** to the **H pin** of the CAN port -4. Connect the **CAN L wire** to the **L pin** of the CAN port -5. **Connect the ground wire** to the **DG pin** for common reference (optional but recommended) -6. If using **shielded cable**, connect the shield to the **SG pin** (recommended for noisy environments) +1. Identify the CAN H and CAN L wires from your CAN device +2. Connect the **CAN H wire** to the **H pin** of the CAN port +3. Connect the **CAN L wire** to the **L pin** of the CAN port +4. **Connect the ground wire** to the **DG pin** for common reference (optional but recommended) +5. If using **shielded cable**, connect the shield to the **SG pin** (recommended for noisy environments) **Ground Connection Best Practices:** - **Always connect DG (Data Ground)** to provide a common reference between devices