Commit Graph
4 Commits
Author SHA1 Message Date
Sleeper85 cb3b0eedba Installed Battery Capacity now follows a capacity change at runtime
The installed total was accumulated once per BMS per boot, latched by
bms<id>_combined_once, so a BMS reconfigured with a different capacity
kept contributing its boot value until the next reboot.

Each BMS now remembers the last capacity it contributed in
bms<id>_installed_capacity and applies only the difference to the total.

- the update runs in the can_be_combined branch, so an offline BMS simply
  stops updating its contribution, which stays in the total : the installed
  capacity still never shrinks on an uncombine, as before
- a BMS coming back with a different capacity is applied as a delta, with
  no double counting
- combined_once had no other reader and is removed

The total is deliberately not turned into a per-round accumulator reset in
the Global vars reset block like the other totals : its sensor is polled
independently of STEP 2 and its state is written straight into CAN frame
0x379 with no has_state() guard, so a transient zero would announce 0 Ah of
installed capacity to the inverter. See Design_decisions.md.
2026-11-08 23:08:33 +01:00
Sleeper85 e4b8aacc0a Fixed 6h reboot on networks that filter the ESP32 outbound traffic
http_request runs on the loop task, which has a 4s budget before the
5s task WDT panics. A dropped connect() blocks for 4.5s (the ESPHome
default timeout) and a filtered port 53 blocks for a fixed 7s, which
timeout does not cover.

- timeout 3s and watchdog_timeout 60s cover the two blocking paths
- a failure counter stops the service after 3 network-level failures,
  instead of freezing the loop 14s every 6h forever
- the POST is now skipped when the GET failed

Reproduced and measured on OPNsense.
See Design_decisions.md.
2026-11-08 23:08:33 +01:00
Sleeper85 4d4d11e832 Auto CVL - Float / Stop (suspended) 2026-11-08 23:08:32 +01:00
Sleeper85 bfa36fb15f Added dev README 2026-11-08 23:08:32 +01:00