Each package now imports its UART from its *_uart_id var and keeps its own baud rate key. WK2168 channels work the same way, uart_flow_control_pin replaces the flow control include, and min_version moves to 2026.10.0. Breaking change.
17 KiB
YamBMS - Waveshare ESP32-S3-RS485-CAN
Important
This board uses a
flow_control_pin, also called atalk_pinin the YamBMS documentation and used to manage the direction of data transmission for RS485 transceiver that do not handle this automatically. Thistalk_pinmust be specified in your YAML. Set it withuart_flow_control_pin: ${talk_pin}in thevars:of the package that uses the UART.
Overview
The Waveshare ESP32-S3-RS485-CAN is an industrial-grade WiFi wireless communicator based on the ESP32-S3 microcontroller. This board is designed for professional IoT applications with built-in isolation and protection circuits, making it particularly well-suited for the YamBMS project thanks to its robust RS485 and CAN bus interfaces.
Key Features:
- Industrial-grade design with multiple protection circuits
- Isolated RS485 and CAN interfaces
- Built-in 120Ω termination resistors (jumper-selectable)
- Digital isolation to prevent signal interference
- Power supply isolation for stable operation
- Wide voltage input range (7-36V DC)
- DIN rail mountable protective enclosure
Board Specifications
| Specification | Details |
|---|---|
| Microcontroller | ESP32-S3-WROOM-1 |
| Processor | Xtensa 32-bit LX7 dual-core @ up to 240MHz |
| FLASH | 16MB |
| PSRAM | 8MB |
| Wireless | Wi-Fi 802.11 b/g/n (2.4GHz) / Bluetooth 5.0 (LE) |
| RS485 | 1× Isolated RS485 interface |
| CAN Bus | 1× Isolated CAN interface |
| UART | 1x SH1.0 interface (not isolated) |
| Power Input (DC Terminal) | 7-36V DC (wide range) |
| Power Input (USB) | 5V via USB Type-C |
| Isolation | Power isolation + Optocoupler isolation |
| Termination | 120Ω resistors (jumper-selectable for RS485 & CAN) |
| LED Indicators | PWR, RS485 TX/RX, CAN |
| Enclosure | Rail-mounted ABS protective case |
| Programming | USB Type-C (firmware download & debugging) |
Interfaces Support Capacity
Based on hardware limitations and testing, this board supports:
| Interface | Maximum | Notes |
|---|---|---|
| CAN | 1x bus | CAN bus to BMS or Inverter |
| RS485 | 1x bus | Best option for monitoring many BMS of the same brand |
| UART | 3× devices¹ | Can be connected to the SH1.0 interface or GPIOs header (shared with RS485) |
| Bluetooth (BLE) | 3× devices¹ | BLE stack consumes significant RAM, may cause crashes/reboots |
¹ BMS / Balancer / Shunt
Note: These are theoretical limits. Not all combinations have been tested.
UART/IO Expander
It would be possible to add one or more WK2168 4x UART expander to increase the number of UART port.
Power Supply
The Waveshare ESP32-S3-RS485-CAN can be powered using two methods:
Option 1: USB Type-C Port
- Connect a USB Type-C cable to the USB port
- Provides 5V power
- Recommended for programming, debugging, and testing
- Convenient for development and troubleshooting
Option 2: External DC Power Supply (Screw Terminal)
- Voltage range: 7V to 36V DC (wide range)
- Connect to the dedicated power screw terminal
- Recommended for permanent installations and industrial environments
- Provides stable power with built-in voltage regulator
- Built-in power supply isolation provides stable isolated voltage
- No extra power supply required for the isolated terminal
Important:
- The board features integrated power isolation for enhanced safety and reliability
- Suitable for harsh industrial environments with voltage fluctuations
- Do not exceed the 36V maximum input voltage
Port Identification and Pinout
RS485 Port
The RS485 interface is isolated and clearly labeled on the board.
RS485 GPIO Pins (Internal):
- TX (GPIO17): RS485 transmit data
- RX (GPIO18): RS485 receive data
- EN (GPIO21): RS485 transceiver enable (automatic switching)
talk_in
RS485 Terminal Block Pinout: The RS485 port typically has a 2-pin screw terminal block:
- A (or +): RS485 A / Data+ (non-inverting)
- B (or -): RS485 B / Data- (inverting)
RS485 Features:
- Isolated interface to avoid external signal interference
- Automatic transceiver mode switching (no manual DE/RE control needed)
- Supports RS485 Modbus and other industrial protocols
- LED indicators:
- Green LED: Lights up when RS485 transmits data
- Blue LED: Lights up when RS485 receives data
CAN Port
The CAN interface is isolated and clearly labeled on the board.
CAN GPIO Pins (Internal):
- TX (GPIO15): CAN transmit (TWAI TX)
- RX (GPIO16): CAN receive (TWAI RX)
CAN Terminal Block Pinout: The CAN port typically has a 2-pin screw terminal block:
- H (or CANH): CAN High
- L (or CANL): CAN Low
CAN Features:
- Isolated CAN interface for easy access to various CAN devices
- Uses ESP32-S3 TWAI (Two-Wire Automotive Interface) controller
- LED indicator: Blinks during CAN data transmission
Wiring Instructions
Connecting RS485 Devices
To connect an RS485 device to the RS485 port:
| RS485 | Terminal Block |
|---|---|
| A + | RS485 A+ (Data+ non-inverting) |
| B - | RS485 B- (Data- inverting) |
Wiring Steps:
- Identify the A and B wires from your RS485 device (may be labeled as D+/D-, A/B, or +/-)
- Connect the A wire (D+ / Data+) to the A+ terminal
- Connect the B wire (D- / Data-) to the B- terminal
- Connect the ground wire to the GND terminal for common reference
RS485 Best Practices:
- Always connect the ground (GND) to provide a common reference between devices
- The board features automatic transceiver mode switching, no manual control needed
- RS485 polarity matters: if communication fails, try swapping A and B connections
- Use twisted pair cable (recommended) to reduce noise and interference
- The isolation protects the ESP32-S3 from high-voltage interference on the RS485 bus
- Monitor communication using the green (TX) and blue (RX) LED indicators
Connecting CAN Bus Devices
To connect a CAN device to the CAN port:
| CAN bus | Terminal Block |
|---|---|
| CAN H | CAN H (CAN High) |
| CAN L | CAN L (CAN Low) |
Wiring Steps:
- Identify the CAN H and CAN L wires from your CAN device
- Connect the CAN H wire to the H (CANH) terminal
- Connect the CAN L wire to the L (CANL) terminal
- Connect the ground wire to the GND terminal for common reference (optional)
CAN Bus Best Practices:
- Always connect the ground (GND) for proper common mode voltage reference
- The board uses the ESP32-S3 TWAI (Two-Wire Automotive Interface) controller
- CAN bus requires proper termination (see Termination Resistors section below)
- Use twisted pair cable specifically designed for CAN bus (120Ω impedance)
- The isolation protects the ESP32-S3 from electrical noise on the CAN bus
- Monitor CAN communication using the CAN LED indicator (blinks during transmission)
- Typical CAN bus speeds: 125 kbps, 250 kbps, 500 kbps, or 1 Mbps
Termination Resistors
One of the key advantages of the Waveshare ESP32-S3-RS485-CAN is its built-in 120Ω termination resistors that can be enabled or disabled via jumpers.
RS485 Termination
The board includes an onboard 120Ω RS485 termination resistor.
How to Enable RS485 Termination:
- Locate the RS485 termination jumper on the board (typically labeled "RS485 120R" or similar)
- Move the jumper cap to the "120R" position to enable the termination resistor
- Move the jumper cap to the "NC" (No Connection) position to disable termination
When to Enable RS485 Termination:
- Enable termination if the board is at one of the two endpoints of the RS485 bus
- RS485 networks require 120Ω termination at both ends of the bus
- If the board is in the middle of the network, keep termination disabled (NC position)
- For short cable runs (<10 meters), termination may be optional but is still recommended
FAQ Note: If RS485 communication is not working, the Waveshare wiki recommends: "Please move the jumper cap to 120R and try again. Some RS485 devices require a 120R resistor to be connected in series."
CAN Bus Termination
The board includes an onboard 120Ω CAN termination resistor.
How to Enable CAN Termination:
- Locate the CAN termination jumper on the board (typically labeled "CAN 120R" or similar)
- Move the jumper cap to the "120R" position to enable the termination resistor
- Move the jumper cap to the "NC" (No Connection) position to disable termination
When to Enable CAN Termination:
- Enable termination if the board is at one of the two endpoints of the CAN bus
- CAN bus requires exactly two 120Ω termination resistors on the entire bus (one at each end)
- If the board is in the middle of the network, keep termination disabled (NC position)
- With proper termination, you should measure ~60Ω between CAN H and CAN L
Termination Tips:
- Always check termination settings before troubleshooting communication issues
- Many CAN devices (like inverters) have built-in termination - verify before adding more
- Incorrect termination is a common cause of CAN communication failures
LED Indicators
The board includes several LED indicators for monitoring system status:
| LED | Color | Function |
|---|---|---|
| PWR | Red/Green | Power indicator - lights up when board is powered |
| RS485 TX | Green | Lights up when RS485 port sends data |
| RS485 RX | Blue | Lights up when RS485 port receives data |
| CAN | Yellow/Green | Blinks during CAN bus data transmission |
These indicators are extremely useful for troubleshooting communication issues in real-time.
Typical YamBMS Configuration
For a typical YamBMS setup with the Waveshare ESP32-S3-RS485-CAN:
-
Power Supply:
- For bench testing: Connect USB Type-C cable (5V)
- For permanent installation: Connect 12V or 24V DC to screw terminal (recommended)
-
BMS Communication (RS485):
- Connect your BMS (e.g., JK, JBD, SEPLOS, PACE, BASEN) to the RS485 port
- Wire according to: A=RS485 A (Data+), B=RS485 B (Data-), GND=Ground
- Enable RS485 termination (120R jumper) if the board is at the end of the RS485 bus
- If the BMS is the only RS485 device, enable termination
-
Inverter Communication (CAN):
- Connect your inverter (e.g., Deye, Sofar, Growatt, Victron) to the CAN port
- Wire according to: H=CAN H, L=CAN L, GND=Ground
- Enable CAN termination (120R jumper) if the inverter is at the end of the CAN bus
- For point-to-point (board ↔ inverter), typically both ends need termination
- Check if your inverter has built-in termination before enabling
-
Verification:
- Power on the board - the PWR LED should light up
- Monitor RS485 communication using green (TX) and blue (RX) LEDs
- Monitor CAN communication using the CAN LED (should blink during transmission)
-
GPIO Pin Configuration:
- RS485: TX=GPIO17, RX=GPIO18, EN=GPIO21
- CAN: TX=GPIO15, RX=GPIO16
Protective Enclosure
The Waveshare ESP32-S3-RS485-CAN comes with a rail-mounted ABS protective enclosure:
Enclosure Features:
- Industrial-grade ABS plastic case
- DIN rail mountable for easy installation in electrical cabinets
- Protects the board from dust, moisture, and physical damage
- Provides professional appearance for industrial installations
- Easy to install and safe to use
Installation:
- The case clips onto standard 35mm DIN rails
- Suitable for use in control panels, switchboards, and industrial enclosures
Programming and Development
Entering Download Mode
If you have trouble uploading firmware:
- Long press the BOOT button
- While holding BOOT, press the RESET button
- Release RESET, then release BOOT
- The module will enter download mode
- Now you can upload your firmware
This solves most download/flashing issues.
Web Interface Demo
Waveshare provides demo firmware with a web interface:
- Default WiFi AP name: ESP32-S3-RS485-CAN
- Default password: waveshare
- The web interface allows control of RS485 and CAN ports
- You can get the device IP via Bluetooth debugging assistant
Additional Resources
Official Waveshare Documentation
- Waveshare ESP32-S3-RS485-CAN Product Page
- Waveshare ESP32-S3-RS485-CAN Wiki
- Schematic Diagram (available on wiki)
Datasheets
Troubleshooting
RS485 Communication Issues
- Check termination jumper - move to "120R" position if board is at bus endpoint
- Verify correct A/B wiring - try swapping if needed
- Check that ground (GND) is connected between devices
- Monitor green (TX) and blue (RX) LEDs to verify data transmission
- Ensure baud rate matches between all RS485 devices
- Test cable continuity and check for damaged twisted pair cable
CAN Bus Communication Issues
- Check termination jumper - move to "120R" position if board is at bus endpoint
- Verify exactly two 120Ω termination resistors are present on entire CAN bus
- Check correct CAN H and CAN L wiring
- Verify ground (GND) is connected for common mode voltage reference
- Measure resistance between CAN H and CAN L (should be ~60Ω with proper termination)
- Monitor CAN LED - it should blink during transmission
- Verify CAN bus speed matches all devices (typically 125k, 250k, 500k, or 1Mbps)
Upload/Programming Issues
- Enter download mode using BOOT + RESET button sequence (see Programming section)
- Verify USB cable supports data transfer (not charge-only)
- Check correct COM port is selected in IDE
- Try different USB cable or USB port on computer
- Ensure USB drivers are installed (CH343P chip)
Power Issues
- Verify power supply voltage is within 7-36V DC range (or 5V via USB)
- Check PWR LED lights up when powered
- Verify polarity of DC power connection
- Do not exceed 36V maximum input voltage
- The board's power isolation should prevent most power-related issues
Isolation Issues
- The board has built-in isolation for both power and communication interfaces
- If experiencing interference issues, verify:
- Ground connections are properly made
- Shielded cables are used in noisy environments
- Isolation jumpers are correctly configured
Comparison with Other Boards
Waveshare ESP32-S3-RS485-CAN vs LilyGo T-Connect
| Feature | Waveshare | LilyGo T-Connect |
|---|---|---|
| RS485 Ports | 1 (isolated) | Up to 3 (isolated) |
| CAN Ports | 1 (isolated) | 1 (isolated) |
| Built-in Termination | ✅ Yes (120Ω jumper-selectable) | ❌ No (external resistors required) |
| Power Isolation | ✅ Yes | ❌ No |
| Signal Isolation | ✅ Yes (RS485 & CAN) | ✅ Yes (RS485 & CAN up to 2500V) |
| Enclosure | ✅ DIN rail ABS case included | ❌ No enclosure |
| Power Input | 7-36V DC or USB-C | 7-12V DC or USB-C |
| LED Indicators | PWR, RS485 TX/RX, CAN | PWR, APA102 support |
| Price | Moderate | Moderate |
| Best For | Single RS485 + CAN with isolation | Multiple RS485 + CAN with isolation |
Summary: The Waveshare board excels in industrial-grade protection and built-in termination, while the LilyGo offers more RS485 ports and configuration flexibility. Choose based on your specific needs:
- Waveshare: Best for harsh environments, built-in termination, ease of installation
- LilyGo: Best for multiple RS485 devices, flexible configuration, compact size
License: This documentation is part of the YamBMS project and follows the same GPLv3 license.
Disclaimer: Always verify specifications and wiring with the official Waveshare documentation before deployment. This guide is community-created and may not reflect the latest product revisions.