2.0 KiB
2.0 KiB
YamBMS - Charging Logic
Charging Logic Diagram
The charging voltage and current correspond to the default values in the YAML script and can be modified.
Cut-Off Charging Logic Equation
Source: Charging Marine Lithium Battery Banks
Special thanks to @shvmm for creating the equations.
Note: The equations below are valid for other chemistries like Li-ion and LTO but with other CVmin and CVmax values.
Cut-Off Charging Logic Diagram (what's happening in the yellow diamond)
Note: The diagram below is valid for other chemistries like Li-ion and LTO but with other CVmin and CVmax values.
LFP Cut-Off Values
- Nominal : 3.20 V
- CV min : 3.37 V
- CV max : 3.65 V
Li-ion Cut-Off Values
- Nominal : 3.60 V
- CV min : 3.90 V
- CV max : 4.20 V
LTO Cut-Off Values
- Nominal : 2.40 V
- CV min : 2.55 V
- CV max : 2.85 V