Files
esphome-yambms/documents
Sleeper85 dfbe4805ad Auto SoC Limit - Follow the Max Charge Current while the CCL limit is held
In the CCL and Float + CCL modes, the offset -(Max Charge Current - Auto
SoC Limit CCL) was computed once, when the target SoC was reached, and
then kept until the SoC dropped below the hysteresis. If the Max Charge
Current increased in the meantime (a pack rejoining the bank, a BMS
raising its limit), the cached offset applied to the larger maximum
released the limit: e.g. 141A requested instead of 1A.

While the target is reached in a CCL mode, the offset is now recomputed
on every pass, before the 60s throttle. A NaN Max Charge Current leaves
the previous offset in place.

Reported in #352
2026-11-14 20:24:19 +01:00
..