YamBMS - JK-PB Inverter BMS

Badge License: GPLv3 Badge Version GitHub stars GitHub forks GitHub watchers

Important

The most important thing for proper functioning of YamBMS is that the voltage of your BMS is well calibrated. YamBMS logic is based on the min_cell_voltage and max_cell_voltage voltages of your BMS. If you use YamBMS, the internal charging logic of the JK-PB BMS will not be used.

JK-PB BMS overview

Image
Image
Image

JK-PB BMS protocol

The datas from this BMS can be retrieved from the RS485-2 (UART2) network using the component JK_RS485 of @txubelaxu.

The BMS DIP switches must be set from 1 to 15 (server mode) and connected to each other using the RS485-2 network available on the two ports at the right ends. YamBMS also connects to one of these two ports.

UART2 configuration

Note

The protocol of the UART2 port is not selectable from the JK application. It is automatically set based on the address (DIP switch) of the BMS.

In the last software version only two protocols are available on the RS485-2 (UART2) ports:

  • 001 - JK BMS RS485 Modbus V1.0 (DIP switch 1 to 15)
  • 015 - UART Protocol 015 (DIP switch 0)

UART1 configuration

The following protocols are supported on the RS485-1 (UART1) port:

(italic options ane not settable)

  • 000 - 4G-GPS Remote module Common protocol V4.2
  • 001 - JK BMS RS485 Modbus V1.0
  • 002 - NIU U SERIES
  • 003 - China tower shared battery cabinet V1.1
  • 004 - PACE_RS485_Modbus_V1.3
  • 005 - PYLON_low_voltage_Protocol_RS485_V3.5
  • 006 - Growatt_BMS_RS485_Protocol_1xSxxP_ESS_Rev2.01
  • 007 - Voltronic_Inverter_and_BMS_485_communication_protocol_20200...
  • 008 - China tower shared battery cabinet V2.0
  • 009 - WOW_RS485_Modbus_V1.3
  • 010 - JK BMS LCD Protocol V2.0
  • 011 - UART1 User customization
  • 012 - UART2 User customization
  • 013 - (9600)JK BMS RS485 Modbus V1.0
  • 014 - (9600)PYLON_low_voltage_Protocol_RS485_V3.5
  • 015 - UART Protocol 015

CAN port configuration

The following CAN protocols are supported on the CAN port:

(italic options ane not settable)

  • 000 - JK BMS CAN Protocol (250K) V2.0
  • 001 - Deye Low-voltage hybrid inverter CAN communication protocol V1.0
  • 002 - PYLON-Low-voltage-V1.2
  • 003 - Growatt BMS CAN-Bus-protocol-low-voltage_Rev_05
  • 004 - Victron_CANbus_BMS_protocol_20170717
  • 005 - MEGAREVO_Hybird_BMSCAN_Protocol_V1.0
  • 006 - JK BMS CAN Protocol (500K) V2.0
  • 007 - INVT BMS CAN Bus protocol V1.02
  • 008 - GoodWe LV BMS Protocol (EX/EM/S-BP/BP)
  • 009 - FSS-ConnectingBat-Tl-en-10 | Version 1.0
  • 010 - MUST PV1800F-CAN communication Protocol1.04.04
  • 011 - LuxpowerTek Battery CAN protocol V01
  • 012 - CAN BUS User customization
  • 013 - CAN BUS Protocol 013
  • 014 - CAN BUS Protocol 014

YamBMS hardware

Tip

This solution only requires an ESP32 with a CAN transceiver and a RS485 transceiver.

You are free to choose the hardware you want, the list below are 3 easy to use examples :

See the documentation about supported hardware.

M5Stack AtomS3 example (no welding)

The example below uses an AtomS3 (display) with the Atomic CAN base and RS485 unit.

Image

Schematic and setup instructions

Caution

Galvanic isolation of the RS485 connection is strongly recommended. The diagrams below does not show the galvanic isolation of the RS485 connection !

Note: the choice of RS485 board is not related to the chosen ESP32.

AtomS3 with unisolated RS485 board

┌──────────┐                 ┌───────────┐                       ┌──────────┐
│          │                 │   UART    │<-VCC--------------5V--│          │<---5V
│   BMS    │                 │    TO     │                       │   ESP32  │
│  JK-PB   │<-RJ45-P1-----B->│   RS485   │<-DI-----------TX--G1--│  Atom S3 │
│          │<-RJ45-P2-----A->│           │--RO-----------RX--G2->│          │                  ┌────────────┐             ┌────────────┐
│  RS485   │                 │ CONVERTER │<-DE--+                │          │--G5--TX-----CTX->|            |             |            |
│ NETWORK  │                 │           │<-RE--└--TALK PIN--G8--│          │<-G6--RX-----CRX--|   Atomic   |<---CAN H--->|  Inverter  |
│          │                 │           │                       │          │<-------5V------->|  CAN Base  |<---CAN L--->|            |
|          |<-RJ45-P3---GND->|           |<-GND-------------GND->|          |<-------GND------>|            |             |            |
└──────────┘                 └───────────┘                       └──────────┘                  └────────────┘             └────────────┘

ESP32-S3 with isolated RS485 board

┌──────────┐                 ┌───────────┐                       ┌──────────┐
│          │                 │   UART    │<-V1--------3V3 or 5V--│          │<---5V
│   BMS    │                 │    TO     │                       │          │
│  JK-PB   │<-RJ45-P1-----B->│   RS485   │<-RX-----------TX--17--│ ESP32-S3 │
│          │<-RJ45-P2 ----A->│           │--TX-----------RX--18->│          │                  ┌────────────┐             ┌────────────┐
│  RS485   │                 │ CONVERTER │                       │          │--38--TX-----CTX->|            |             |            |
│ NETWORK  │                 │           │      No TALK PIN (8)--│          │<-39--RX-----CRX--|    CAN     |<---CAN H--->|  Inverter  |
│          │                 │           │                       │          │<-------3V3------>| SN65HVD230 |<---CAN L--->|            |
|          |<-RJ45-P3----G2->|           |<-G1--------------GND->|          |<-------GND------>|            |             |            |
└──────────┘                 └───────────┘                       └──────────┘                  └────────────┘             └────────────┘

BMS DIP switch config (mode 2)

With mode 2, the sniffer (ESP32) will automatically take the address 0x00 and act as master BMS (max 15 BMS).

  • BMS 1 RS485 address : 0x01
  • BMS 2 RS485 address : 0x02
  • BMS 3 RS485 address : 0x03
  • etc.

JK-PB RS485 functions

Broadcasting JK-PB settings to all BMS

Image

When enabled, this function synchronizes the settings of all your BMS connected to the same RS485 network as soon as you make parameter changes.