YamBMS behavior
Shunt and BMS combination
The various counters above allow you to see what state your system is in.
Shunt/BMS combine status
- Combine Availability : This status indicates whether the
BMSorShuntmeets the conditions to be combined. - Can be combined : This status indicates whether the
BMSorShuntis currently combined.
Shunt
Combine condition :
- the
Combineswitch is enabled - Shunt
Online StatusisON(the shuntVoltageis> 0V)
If one of these two conditions is not respected, the shunt is automatically uncombined.
Important
In RS485 modbus
multi-node, if a server does not respond (cable or hardware failure) theOnline Statusof the shunt will be set toOFFand it will be uncombined.
As soon as you import a Shunt and it can be combined (see condition) the values Voltage, Current, Power and SoC of the shunt(s) will take precedence over the BMS values.
Note
If all BMS are
uncombinedthe shunt data will no longer be published.
BMS
Combine condition :
- the
Combineswitch is enabled - BMS
Online StatusisON(to detect a loss of connection with the BMS e.g. cable, BMS OFF or dead) - BMS
ChargingorDischargingis allowed (based onbinary_sensor, related to the state ofswitches/alarms)
If one of these three conditions is not met, the BMS is automatically uncombined.
Important
In RS485 modbus
multi-node, if a server does not respond (cable or hardware failure) theOnline Statusof the BMS will be set toOFFand it will be uncombined.
From YamBMS 1.5.1 :
The binary_sensor does not only represent the state of the charge/discharge switches but simply whether the charge/discharge is allowed. The value of binary_sensor is related to the status of the switches/alarms.
The errors_bitmask should not be a condition to combine a BMS anymore, let the BMS decide if the charge/discharge is allowed (its alarm system takes care of that).
The errors_bitmask continues to be analyzed to send warnings/alarms on the CAN bus.
The behavior of the Charging Instruction and Discharging Instruction sensors responsible for the instructions sent to the inverter will also be adapted. Alarm analysis will no longer be checked. If at least one BMS allows charging, charging can continue, if at least one BMS allows discharging, discharging can continue. This will also be based on the binary_sensor related to the state of switchs/alarms of the BMS.
If a BMS blocks charging or discharging, the permitted current is automatically reduced.
State of Charge
The SoC is slightly manipulated before reaching 0% or 100%.
SoC 100% will be sent to your inverter only when the battery is fully charged (useful for some inverters stopping charging when the SoC reaches 100%).
SoC behavior:
- If
min_cell_v <= UVP + 0.02VSoC 0% is sent - Else if
SOC < 1%SoC 2% is sent (false 0% sending 2%) - Else if
SOC < 99%real SoC is sent - Else if
the battery is fully chargedreal SoC is sent - Else SoC
98%is sent
CAN bus link
For the CAN bus link to be established with your inverter, the two conditions below must be met:
- At least one BMS is in service (the number of combined BMS must be
> 0) - Your inverter sends an
ACK 0x305every1s(the link will be faulty if no ACK is received for 5s)
If these conditions are not met, the application waits 60s before trying to connect again.
Extra infos
Sending CAN frames continues without an inverter connected is problematic and will lead to ESP32 crash.
During boot the CAN bus links are activated directly if at least one BMS is combined and the inverter responds to the sending of CAN frames within a 5s delay.
This 5s delay represents the time during which the link is valid, this timer is reset each time an ACK 0x305 is received from the inverter.
This 5s delay can be modified in the configuration when importing the canbus package.
canbus1: !include
file: packages/yambms/yambms_canbus.yaml
vars:
canbus_id: 'canbus1'
canbus_name: 'CANBUS 1'
canbus_node_id: 'canbus_node1'
canbus_light_id: 'esp_light'
# The CANBUS link will be considered down if no response from the inverter (ID 0x305) for 5s
canbus_link_timer: '5s'
If the inverter does not respond with an ACK 0x305 within this 5s delay the sending of CAN frames is paused for 60s this delay cannot be modified when importing the canbus package but you can modify it in the code if you need to.
BMS alarms
The BMS errors_bitmask values are merged and then analyzed continuously even if the BMS is uncombined.
If all BMS have alarms, the alarms are sent to the CAN bus as Protection Alarms.
If at least one BMS has no alarms, the alarms are sent to the CAN bus as Warning.
Both text_sensor Alarm and Warning show the alarms/warnings currently transmitted to the inverter.