This function allows to set a target time when `Bulk` charging. It limits the `Requested Charge Current (CCL)` so the battery should reach full charge at the specified time.
14 KiB
YamBMS functions
CAN protocol
Important
You need to check if your inverter model is on the list of supported inverters. In any case it must support one of the following
CANbus protocols.
Choose the CAN protocol that will be sent to your inverter and don't forget to configure your inverter for the protocol you choose.
The table below helps you choose the best protocol depending on your inverter brand. Other configurations are possible, don't hesitate to communicate what works well for you.
| Inverter | Battery mode | CAN protocol |
|---|---|---|
| Deye | Lithium 00 | PYLON 1.2 |
| GoodWe | LX U5.4-L | PYLON V2 |
| Sofar | Automatic | PYLON 1.2 |
| Growatt | CAN L52 | PYLON 1.2 |
| Solis | AoBo | SMA |
| LuxPower | Lithium 6 | LuxPower |
| EG4 | Lithium 6 | LuxPower |
| Victron | CAN-bus BMS LV (500 kbit/s) | Victron |
| MidNite Solar | PYLON | PYLON 1.2 |
| SMA | - | SMA |
Charging settings
The Charging status represents the current charging phase, see the Charging logic.
The Charging instruction is defined based on the Charging status and allows the correct Requested Charge Values to be sent.
The Float charge enabled switch allows the battery to be kept fully charged at the end of the Bulk charge. The voltage used will be that of the Float voltage slider.
The EOC timer enabled switch ensures that the Cut-Off phase lasts maximum 30 min (default value) even if your cells are still being equalized. If your cells are equalized, the Cut-Off phase will end at the earliest after 60s (default value). This prevents the risk of staying in the Cut-Off phase for many hours if you have several batteries and they are poorly equalized.
Important
If you have totally unbalanced batteries and want to fix this problem, you can disable the
EOC timerand letYamBMSbalance your batteries, this can take hours. A well balanced battery does not need this timer enabled as the equalization phase will finish in less than 30 minutes.
The Bulk voltage slider allows you to set the voltage used during the Bulk, Balancing and Cut-Off phases.
The Float voltage slider allows you to set the voltage used after charging is complete if the Float charge enabled switch is enabled.
The Inverter Offset V. slider allows you to correct the inverter charge voltage, either because it does not respect the requested value or because your inverter is far from your batteries and there is a voltage drop. This allows you to reach the target Bulk or Float charge voltage by adding an offset.
Max current (%)
The allowed charge or discharge current is automatically calculated based on the OCP values of your BMS. The OCP currents of the combined BMS (not in alarm) are added together and the requested current is a percentage 0~90% of this value.
ReBulk
There are two parameters to start a new Bulk phase. You can set a Rebulk SoC or a Rebulk V. value, only one of these conditions must be met.
If needed you can also force a Bulk charge with the Force Bulk (top bal) switch. The switch will automatically deactivate when your cells enter the Balancing phase.
Request Force Charge
This function allows you to force a charge from GRID :
- when
SoC <= Start SoCthe forced charge start - when
SoC >= Stop SoCthe forced charge stop
Works only with PYLON, LuxPower and Victron protocols.
Auto functions
Thanks to @MrPabloUK for developing Auto CVL, Auto CCL and Auto DCL functions.
A reference spreadsheet has been created that shows how the Auto CVL, CCL & DCL works.
Thanks to @GHswitt for developing Auto Float function.
Auto CVL
Important
The
Auto CVLfunction uses theBalance Trig. Volt.value of your BMS.e.g. for LFP: BTG=0.010V
When enabled, the Automatic Charge Voltage Limit feature will automatically reduce the Requested Charge Voltage (CVL) sent to the inverter when a cell starts to exceed the bulk target.
That way, the runner cell should be maintained at or near bulk (for example, 3.45v) and the balancer can start to bring up the lagging cells.
Controlling the CVL is the preferred option according to Victron and others, but it depends on how well your inverter behaves.
My Solis inverter is not great at CVL control, so it doesn't work well for me.
You can compare Auto CVL to cruise control in a car.
Boost Charge V. allows you to increase the charging voltage to charge your battery faster, the Auto CVL function will itself reduce the charging voltage at the end of charging so that it does not exceed the target voltage Bulk Voltage.
Auto CCL & DCL
Important
The
Auto CCLfunction uses theOVPvalue of your BMS. TheAuto DCLfunction uses theUVPvalue of your BMS.
Regarding the new Auto Charge/Discharge Current Limit, this features has been introduced to hopefully prevent OVP and UVP alarms.
When enabled, the Automatic Charge Current Limit feature will automatically reduce the Requested Charge Current (CCL) sent to the inverter when a cell starts to exceed the bulk target.
This should prevent the runner cell from exceeding the max voltage cutoff, but doesn't maintain it at bulk voltage - instead it should keep it just below max cell voltage.
You can compare Auto CCL to a max speed limiter in a car.
Auto DCL works the same way when a cell approaching UVP + 0.2.
Current control should work with any inverter that uses CAN control.
Auto Float Voltage
When switching from Bulk to Float, therefore lowering the Requested Charge Voltage (CVL), some inverters (e.g. Deye SUN-12K) will start to discharge the battery (into the grid) with up to max. discharge current until the
Requested Charge Voltage (CVL) is reached. The reason behind this is that the inverter sees this as battery overvoltage and wants to counter it.
As workaround, by enabling Automatic Float Voltage, it will lower the Requested Charge Voltage (CVL) gradually in small steps until the float voltage is reached, allowing the battery more time to settle down.
There are two modes available: Follow and Immediately.
Follow: Waits until the battery voltage itself is below the currentRequested Charge Voltage (CVL)before loweringRequested Charge Voltage (CVL)further. It follows the battery voltage until the target float voltage is reached.Immediately: Immediately start lowering theRequested Charge Voltage (CVL), independent of the current battery voltage. That means it can go below the current battery voltage.
This feature might not work with all inverters as good or is not required if these do not discharge the battery.
The voltage steps can be configured (default 0.1V) with Auto Float Voltage Step. The update interval can be configured (default 3 minutes) with Auto Float Update Interval.
Auto EOC
When to use: Your battery would be full early in the day and then be idle for the rest of the day. You want to charge it slowly and have it full at a specified time, for example in the evening.
This function allows to set a target time when Bulk charging. It limits the Requested Charge Current (CCL) so the battery should reach full charge at the specified time. As the algorithm is quite simple there are some requirements for it to work correctly:
- The time of the ESPHome device must be correct and available.
- The
Battery Capacitymust be correct. - The charger/inverter can deliver the
Requested Charge Current (CCL)over the time frame -> the sun must be shining.
There are some configuration options to adjust the behaviour:
Automatic EOC Current: This switch enables or disables the function. When disabled, it will not limit theRequested Charge Current (CCL).Auto EOC Target Hour: This selects the hour of the desired target time.Auto EOC Target Minute: This selects the minute of the desired target time.Auto EOC Correction: This increases or decreases theRequested Charge Current (CCL)and allows for correcting charger/inverter differences, for example if the inverter delivers less current than requested.Auto EOC Capacity Modifier: This allows to lower the target capacity for the calculation. If your batteryCapacity Remainingdoes not reachBattery Capacitywhen 100% full, you can adjust the value here.Auto EOC Increase Stop Hours: When nearing the target time but the charge current can not be reached, theRequested Charge Current (CCL)will increase until it reaches the max. charge current. To avoid this, a time frame bevor the target time can be chosen in which the current will not be increased. E.g. if this option is set to 1 hour, theRequested Charge Current (CCL)is 40A and the time is betweenTarget Hour - 1 hourandTarget Hour, it will stay at 40A.Auto EOC Increase Stop SoC: Similar toAuto EOC Increase Stop Hours, this stops increasing theRequested Charge Current (CCL)when theSoCis equal or above the specifiedSoC.
The text sensor Auto EOC Status will show the current status of the function:
Stop: Disabled: Function is disabled or capacity not available.Stop: Float: YamBMS currently inFloatmode, notBulk.Stop: Time not valid: The ESPHome device time is not valid.Stop: Target time passed: The current time is after the selected target time.Stop: Current above limit: The required charge current is above the current charge limit.Run: Current increase stopped: Running, but no current increase because ofAuto EOC Increase Stop HoursorAuto EOC Increase Stop SoC.Run: Working normally.
The sensor Auto EOC Current will show the calculated charging current. Note that it is filtered by an EWMA filter with a default 3 minute delay.
That means that changes to the options or parameters are not immediately visible. This avoids that the Requested Charge Current (CCL) will fluctuate too much. It will show 0A when the function is disabled/stopped or there is no solution.
The function used to calculate the required charging current is very basic. The missing battery capacity (difference between Battery Capacity and Capacity Remaining) divided by the remaining hours. It will be updated every minute, but afterwards filtered before it is used for Requested Charge Current (CCL). That means it will adapt, but not take into account any special circumstances. For example if Auto CCL is enabled and required, the charge current may further be limited by Auto CCL. The target time may then not be reached exactly. To account for this, the parameter Auto EOC Correction can be used to increase the overall current a little to compensate for the lower end current.
Here is an example when the target time is set to 18:00. Starting at 00:00, the required current increases as the battery is discharged. When the battery starts charging as the sun is up, the required current stabilizes around 14A.
The current is increased at the end as it does not exactly hit its required charge, but at 17:30, the required current is stable because the parameter Auto EOC Increase Stop Hours was set to 0.5 hours, so it will not be increased anymore.
At about 18:08 the battery is 100% after a short balancing period.
Requested Values
These 4 sensors allow you to see what is being requested of your inverter.
In the example below, we are in the Float phase at a voltage of 53.6V and an Inverter Offset V. of 0.1V. The Requested Charge Voltage is therefore 53.7V.
The Requested Discharge Voltage is the UVP + 0.2 value of your BMS multiplied by the number of cells, in this example (3V * 16).
The Requested Charge/Discharge Current is the OCP value of your BMS multiplied by the Max current percentage, in this example (150A * 80%).
Inverter Heartbeat Monitoring
This feature allows you to monitor the heartbeat of your inverter (time between two ACK 0x305). This is useful for troubleshooting purposes and should not remain enabled continuously.
This heartbeat must be regular and depends on the selected CAN protocol and the behavior of the inverter. If the heartbeat is not regular this can show a problem on the inverter side or an overloaded ESP32.
The Deye inverter sends an ACK 0x305 in response to the reception of a CAN frame 0x356. Knowing that CAN frames are sent every 100ms and that the CAN protocol PYLON 1.2 has 6 CAN frames, the heartbeat of the Deye inverter is 600ms.
Important
Every
2hDeye takes more than3sto respond and more than5sat midnight. This is what theCANBUS Statuslooks like when thecanbus_link_timeris set to3s.
Diagnostic
Useful information for troubleshooting.
YamBMS version
This function lets you know if a new version of YamBMS is available, the check is done every 6 hours.