# Updated : 2026.06.29
# Version : 1.1.9
# GitHub : https://github.com/Sleeper85/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
# This YAML is free software: you can redistribute it and/or
# modify it under the terms of the GNU General Public License
# as published by the Free Software Foundation, either version 3
# of the License, or (at your option) any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
# See the GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with this program. If not, see <http://www.gnu.org/licenses/gpl.html>.
# +--------------------------------------------------------------------------------+
# | Import this package into your main YAML once for each BMS to enable this logic
# +--------------------------------------------------------------------------------+
#
# - path: packages/bms/bms_options_charging_logic.yaml
# vars:
# bms_id: '1' # must be a number
# - path: packages/bms/bms_options_charging_logic.yaml
# vars:
# bms_id: '2' # must be a number
# - path: packages/bms/bms_options_charging_logic.yaml
# vars:
# bms_id: '3' # must be a number
#
# +--------------------------------------------------------------------------------+
substitutions:
bms_cutoff_timer: '50s' # time during which the end of charge conditions must be respected (cut-off + cells not equalizing)
script:
- id: bms${bms_id}_script_cutoff_timer
then:
- delay: ${bms_cutoff_timer}
- switch.turn_off: bms${bms_id}_charge_switch
- lambda: ESP_LOGD("yambms_debug", "BMS ${bms_id} charge_switch Turn OFF");
interval:
- interval: ${yambms_update_interval}
then:
- lambda: |-
id(yambms${yambms_id}_var_bms_charging_logic) = true;
// Charge switch `Turn ON` conditions (Charge switch OFF and ReBulk V.)
if (!id(bms${bms_id}_charge_switch).state && (id(yambms${yambms_id}_var_charge_status) == "EOC" || id(yambms${yambms_id}_var_charge_status) == "Float"))
{
id(bms${bms_id}_charge_switch).turn_on();
ESP_LOGD("yambms_debug", "BMS ${bms_id} charge_switch Turn ON");
}
// Charge switch `Turn OFF` conditions
else if (id(yambms${yambms_id}_var_charge_status) == "Cut-Off")
{
// The cells are equalizing
if (id(bms${bms_id}_equalizing).state)
{
// Stop cut-off timer
if (id(bms${bms_id}_script_cutoff_timer).is_running()) id(bms${bms_id}_script_cutoff_timer).stop();
}
// The cells are not equalizing and Cut-Off timer not running
else if (!id(bms${bms_id}_script_cutoff_timer).is_running())
{
// Start cut-off timer
// If the conditions continue to be respected the `Charge switch` will be turned OFF
id(bms${bms_id}_script_cutoff_timer).execute();
}
}
// Cut-off timer is running ?
else if (id(bms${bms_id}_script_cutoff_timer).is_running())
{
id(bms${bms_id}_script_cutoff_timer).stop(); // Stop cut-off timer
}