11 KiB
YamBMS - JK-PB Inverter BMS
Important
The most important thing for proper functioning of YamBMS is that the voltage of your BMS is well calibrated. YamBMS logic is based on the
min_cell_voltageandmax_cell_voltagevoltages of your BMS. If you use YamBMS, the internal charging logic of theJK-PB BMSwill not be used.
JK-PB BMS overview
![]() |
|---|
![]() |
![]() |
JK-PB BMS protocol
The datas from this BMS can be retrieved from the RS485-2 (UART2) network using the component JK_RS485 of @txubelaxu.
The BMS DIP switches must be set from 1 to 15 (server mode) and connected to each other using the RS485-2 network available on the two ports at the right ends. YamBMS also connects to one of these two ports.
UART2 configuration
Note
The protocol of the
UART2port is not selectable from the JK application. It is automatically set based on the address (DIP switch) of the BMS.
In the last software version only two protocols are available on the RS485-2 (UART2) ports:
- 001 - JK BMS RS485 Modbus V1.0 (DIP switch 1 to 15)
- 015 - UART Protocol 015 (DIP switch 0)
UART1 configuration
The following protocols are supported on the RS485-1 (UART1) port:
(italic options ane not settable)
- 000 - 4G-GPS Remote module Common protocol V4.2
- 001 - JK BMS RS485 Modbus V1.0
- 002 - NIU U SERIES
- 003 - China tower shared battery cabinet V1.1
- 004 - PACE_RS485_Modbus_V1.3
- 005 - PYLON_low_voltage_Protocol_RS485_V3.5
- 006 - Growatt_BMS_RS485_Protocol_1xSxxP_ESS_Rev2.01
- 007 - Voltronic_Inverter_and_BMS_485_communication_protocol_20200...
- 008 - China tower shared battery cabinet V2.0
- 009 - WOW_RS485_Modbus_V1.3
- 010 - JK BMS LCD Protocol V2.0
- 011 - UART1 User customization
- 012 - UART2 User customization
- 013 - (9600)JK BMS RS485 Modbus V1.0
- 014 - (9600)PYLON_low_voltage_Protocol_RS485_V3.5
- 015 - UART Protocol 015
CAN port configuration
The following CAN protocols are supported on the CAN port:
(italic options ane not settable)
- 000 - JK BMS CAN Protocol (250K) V2.0
- 001 - Deye Low-voltage hybrid inverter CAN communication protocol V1.0
- 002 - PYLON-Low-voltage-V1.2
- 003 - Growatt BMS CAN-Bus-protocol-low-voltage_Rev_05
- 004 - Victron_CANbus_BMS_protocol_20170717
- 005 - MEGAREVO_Hybird_BMSCAN_Protocol_V1.0
- 006 - JK BMS CAN Protocol (500K) V2.0
- 007 - INVT BMS CAN Bus protocol V1.02
- 008 - GoodWe LV BMS Protocol (EX/EM/S-BP/BP)
- 009 - FSS-ConnectingBat-Tl-en-10 | Version 1.0
- 010 - MUST PV1800F-CAN communication Protocol1.04.04
- 011 - LuxpowerTek Battery CAN protocol V01
- 012 - CAN BUS User customization
- 013 - CAN BUS Protocol 013
- 014 - CAN BUS Protocol 014
YamBMS hardware
Tip
This solution only requires an ESP32 with a CAN transceiver and a RS485 transceiver.
You are free to choose the hardware you want, the list below are 3 easy to use examples :
AtomS3with the isolatedAtomic CAN baseandRS485 unitLilyGo T-Connect, ESP32-S3 with 3x RS485 and 1x CANLilyGo T-CAN485, ESP32 with 1x RS485 and 1x CAN
See the documentation about supported hardware.
M5Stack AtomS3 example (no welding)
The example below uses an AtomS3 (display) with the Atomic CAN base and RS485 unit.
Schematic and setup instructions
Caution
Galvanic isolation of the
RS485connection is strongly recommended. The diagrams below does not show the galvanic isolation of theRS485connection !
Important
If you are unable to read your BMS from the
RS485bus, add a120 Ohmresistor between theAandBwires connected to yourRS485board. This must be done with theM5Stack RS485 unit, some boards have a switch to enable the bus termination resistor.
Note: the choice of RS485 board is not related to the chosen ESP32.
AtomS3 with unisolated RS485 board
┌──────────┐ ┌───────────┐ ┌──────────┐
│ │ │ UART │<-VCC--------------5V--│ │<---5V
│ BMS │ │ TO │ │ ESP32 │
│ JK-PB │<-RJ45-P1-----B->│ RS485 │<-DI-----------TX--G1--│ Atom S3 │
│ │<-RJ45-P2-----A->│ │--RO-----------RX--G2->│ │ ┌────────────┐ ┌────────────┐
│ RS485 │ │ CONVERTER │<-DE--+ │ │--G5--TX-----CTX->| | | |
│ NETWORK │ │ │<-RE--└--TALK PIN--G8--│ │<-G6--RX-----CRX--| Atomic |<---CAN H--->| Inverter |
│ │ │ │ │ │<-------5V------->| CAN Base |<---CAN L--->| |
| |<-RJ45-P3---GND->| |<-GND-------------GND->| |<-------GND------>| | | |
└──────────┘ └───────────┘ └──────────┘ └────────────┘ └────────────┘
ESP32-S3 with isolated RS485 board
┌──────────┐ ┌───────────┐ ┌──────────┐
│ │ │ UART │<-V1--------3V3 or 5V--│ │<---5V
│ BMS │ │ TO │ │ │
│ JK-PB │<-RJ45-P1-----B->│ RS485 │<-RX-----------TX--17--│ ESP32-S3 │
│ │<-RJ45-P2 ----A->│ │--TX-----------RX--18->│ │ ┌────────────┐ ┌────────────┐
│ RS485 │ │ CONVERTER │ │ │--38--TX-----CTX->| | | |
│ NETWORK │ │ │ No TALK PIN (8)--│ │<-39--RX-----CRX--| CAN |<---CAN H--->| Inverter |
│ │ │ │ │ │<-------3V3------>| SN65HVD230 |<---CAN L--->| |
| |<-RJ45-P3----G2->| |<-G1--------------GND->| |<-------GND------>| | | |
└──────────┘ └───────────┘ └──────────┘ └────────────┘ └────────────┘
BMS DIP switch config (mode 2)
With mode 2, the sniffer (ESP32) will automatically take the address 0x00 and act as master BMS (max 15 BMS).
This is the preferred mode with YamBMS.
- BMS 1 RS485 address : 0x01
- BMS 2 RS485 address : 0x02
- BMS 3 RS485 address : 0x03
- etc.
MODE 1 vs MODE 2
MODE 1. If there is a JK-BMS acting as REAL MASTER (i.e. it has set 0x00 address), the code will be sniffing all the traffic in the network. The problem is that there is some information that is NEVER in the sniffed traffic information (device info frame type 03): device-name, hw version, sw version, password, RCV Time, RFV Time... So, periodically, ESP code will act as a PSEUDO-MASTER to try to get this information. It works for every slave device, but not for master device. At this moment, master device does NOT broadcast by itself the "frame type 03" info. And it does not answer to a "frame type 03" request sent by PSEUDO MASTER.
MODE 2. If every JK-BMS are set as SLAVES (all of them), the ESP code will act as MASTER. So, if ESP code does not detect any REAL MASTER in the network, it will act as a MASTER. Remember to adapt DIP switches and the YAML (addresses) as well. Changing the addreses of the devices does not affect to the historic data gathered from that device, because the config is based on the NAME of the device and not on the address of the device. So, change the address, but not the name. In this mode, ESP will gather all the information (cell info, device settings and device info). If anytime, a REAL MASTER arrives to the network, ESP will detect it and will stop acting as MASTER.
JK-PB RS485 functions
Broadcasting JK-PB settings to all BMS
When enabled, this function synchronizes the settings of all your BMS connected to the same RS485 network as soon as you make parameter changes.
JK-PB SoC 100% reset
Note
During the
Bulkphase the YamBMSSoCcannot be more than98%. When the battery is fully charged, thereal SoCwill be sent.
The RCV, RFV, and RCV timer values are not used by YamBMS.
But they are used by the JK-BMS to reset the SOC to 100%.
If you are instructing YamBMS to charge at 3.45V/cell, set the JK RCV value lower to 3.40V and reduce the RCV timer to 15 minutes.
This will reset the SoC to 100% faster.