YamBMS behavior
Shunt and BMS combination
Combine status
Combine Availability : This status indicates whether the BMS or Shunt meets the conditions to be combined.
Can be combined : This status indicates whether the BMS or Shunt is currently combined.
Shunt
Combine condition :
- the
Combineswitch is enabled - the
Voltagesupplied by the shuntis > 0V
If one of these two conditions is not respected, the shunt is automatically decombined.
As soon as you import a shunt and it can be combined (see condition) the values (Voltage, Current, Power and SoC) of the shunt(s) will take precedence over the BMS values.
BMS
Combine condition :
- the
Combineswitch is enabled - BMS
ChargingorDischargingswitch is enabled - BMS is not in
alarm
If one of these three conditions is not met, the BMS is automatically decombined.
BMS alarms
Important
This is the current behavior, it may not be perfect, feel free to communicate your ideas to improve it.
The errors_bitmask values are merged and then analyzed continuously even if the BMS is uncombined.
As long as at least one BMS is working normally the system will continue to work.
YamBMS will display BMS alarms as Warning.
If all BMS are in alarm, they are all uncombined and in this case the sending of instructions on the CAN bus is also stopped.
YamBMS will display BMS alarms as Alarm.