Sleeper85 eee476340d YamBMS - Stop the Cut-Off and EOC timers in Wait and while no BMS is combined
The cut-off timer (180s) and the EOC timer (30min) were only stopped when
the Bulk phase was re-entered. While the charging logic was suspended (no
BMS combined) or in Wait (charging not allowed), they kept running, so a
dropout or a charge block during the Cut-Off phase could declare an EOC
with no BMS data to confirm it: the status went to Float or EOC, SoC 100%
could be sent and the rebulk days counter was reset.

Both timers are now stopped while the logic is suspended and whenever the
status is set to Wait. With bms_options_charging_logic.yaml, Wait is only
entered when the Charging switch is off, so the Cut-Off performed by
YamBMS itself is not affected. When charging is allowed again after a
Wait in Cut-Off, a new Bulk starts and the Cut-Off phase is run again.

Charging_logic.md is updated accordingly.

Reported in #352