@@ -7,31 +7,41 @@
|
||||

|
||||
|
||||
* YamBMS 1.8.0 :
|
||||
* Set esphome `min_version` to `2026.8.0`
|
||||
* Updated HA dashboards `1.8.0` for the new Cut-Off Cell Voltage, Charger Offset V., C-Rate and Auto CCL Current Taper entities
|
||||
* Rewritten Cut-Off / EOC charging logic : adds a current deadband (rejects sensor noise / low-solar current limiting) and a minimum SoC gate before Cut-Off can be declared, extends the cut-off confirmation delay from 60s to 180s to reject transient voltage readings, see [release note](documents/README/changelog/Changelog_YamBMS_1.8.0_Cut-Off_charging_logic.md)
|
||||
* New select `Cut-Off Cell Voltage` : choose between `Max Cell Voltage` (default, conservative) and `Average Cell Voltage` (consistent charge termination voltage for packs with a runner cell, requires Auto CVL and/or Auto CCL for cell protection)
|
||||
* New sliders `Max charge C-Rate` / `Max discharge C-Rate` : the max charge/discharge current is now the lowest of the user slider, the BMS OCP safety margin, and battery capacity × C-Rate
|
||||
* Renamed `Inverter Offset V.` to `Charger Offset V.` and allowed negative values (-1V to +1V)
|
||||
* `Requested Charge Voltage (CVL)` calculation reworked : it is now built as a per-phase base target (`Bulk` → bulk voltage, `Float` → float voltage, `Stop` → nominal voltage) plus a common set of offsets (`Charger Offset V.`, `Auto CVL`, `Auto Float` and the new `Auto Custom CVL`, each `0` when its function is idle or disabled), instead of one hardcoded formula per phase ; `Stop` charging voltage target changed from `Rebulk V.` to nominal voltage, so the pack no longer sits on the very threshold that decides when to rebulk.
|
||||
* Auto CVL : rewritten from a per-second template sensor to an interval lambda, now exposed as two sensors (`Auto CVL` value + `Auto CVL Delta`) instead of one internal-only sensor ; it remains a `Bulk`-only correction, the `Float`/`Stop` slot of the new formula being left free for a future implementation
|
||||
* Auto Float : rewritten from a per-minute template sensor to an interval lambda, now exposed as two sensors (`Auto Float Voltage` value + `Auto Float Voltage Delta`) ; no behavior change
|
||||
* Auto EOC : new 1-hour grace period holding the last computed current after target time passes (instead of releasing to maximum current), smoothed remaining-capacity estimate between BMS 1% SoC steps to remove current sawtoothing, `Stop SoC` slider capped at 98% (100% could never trigger because SoC is clamped to 98% until end-of-charge)
|
||||
* New `Auto CCL Current Taper` function : tapers CCL from a configurable knee voltage/C-Rate down to a bulk C-Rate, then holds a configurable balance current while at bulk or after EOC ; release hysteresis and Balance Current max are now scaled to cell count/battery capacity instead of flat constants, and a NaN guard prevents a spurious taper during the boot transient, see [changelog](documents/README/changelog/Changelog_Auto_CCL_Current_Taper_1.1.2.md)
|
||||
* `Requested Charge Voltage (CVL)` calculation reworked : `Auto CVL`, `Auto Float` and the new `Auto Custom CVL` are now summed on top of the phase target in every charging phase (`Bulk`/`Float`/`Stop`), instead of `Auto CVL` silently applying a Bulk-anchored correction during Float/Stop too ; `Auto CVL` now has dedicated Float/Stop behavior (based on average cell voltage, one-directional, chained floors down to nominal/discharge voltage) instead of only correcting Bulk ; `Stop` charging voltage target changed from `Rebulk V.` to nominal voltage, see [changelog](documents/README/changelog/Changelog_YamBMS_1.8.0_Auto_CVL.md)
|
||||
* Fixed HA dashboards : `Auto CCL Current Taper` card's switch pointed to a non-existent entity id and never toggled
|
||||
* New substitutions `custom_ccl_derating_reason` / `custom_dcl_derating_reason` allowing a custom current-limiting source (e.g. added via `yambms_custom.yaml`) to report itself in the CCL/DCL derating reason sensor, and a similar `Auto Custom CVL` slot for voltage
|
||||
* The CCL/DCL auto-limiting globals are now reset at the start of every cycle instead of only being overwritten by their owning function, preventing a past derating reason/value from getting silently stuck if the condition that caused it disappears
|
||||
* Fixed incorrect Max/Min Cell Voltage scaling (×100 instead of ×1000) sent on the CAN bus for the Deye PCS protocol
|
||||
* Improved PACE BMS Modbus : power is now computed from current × voltage instead of a raw register (fixes incorrect readings), improved offline detection
|
||||
* Updated EG4 LL-V2 component to [v1.1.0](https://github.com/RAR/esphome-eg4-bms/releases/tag/v1.1.0) : fixes [issue 7](https://github.com/RAR/esphome-eg4-bms/issues/7), some EG4 LL-V2 units intermittently answer with a CRC-valid response whose register data is entirely zero, which was published as a real reading and collapsed SoC / voltage / capacity for one poll cycle ; those blocks are now rejected and no longer refresh the online tracker
|
||||
* Reworked Modbus timing options : `send_wait_time` is now a response timeout (default lowered from 2000ms to 200ms) and a new `turnaround_time` option was added; shared multi-node settings (`yambms_config.yaml`) updated accordingly
|
||||
* Improved PACE BMS Modbus : power is now computed from current × voltage instead of a raw register (fixes incorrect readings), improved offline detection
|
||||
* Sensors (Total Voltage, Current, Power, SoC, Requested CVL/DVL/CCL/DCL, etc.) now publish as unavailable (`NaN`) instead of `0` when no BMS is combined
|
||||
* Fixed `Installed Battery Capacity` frozen until reboot : the value was summed once per BMS at boot, so a BMS whose capacity was reconfigured at runtime kept contributing its old value ; each BMS now applies only the difference to the total, which still never shrinks when a BMS goes offline
|
||||
* Multi-inverter / multi-charger support : the requested CCL/DCL is now divided by the number of declared CAN/RS485 inverter interfaces, so several identical inverters/chargers sharing the same battery bank each receive their share of the limit instead of every unit requesting the full value, see [documentation](documents/README/YamBMS_functions.md#multi-inverter--multi-charger)
|
||||
* New `Combiner Stall` diagnostic sensor : reports which BMS or Shunt id the combiner pipeline is stuck on when `bms_id`/`shunt_id` numbering has a gap, instead of stalling silently with no combined values; added the new `Combiner Stall` diagnostic row in dashboard
|
||||
* New `Fake Equalizing` : BMS that balance their cells but never report a balancing flag had it hardcoded to `false`, so the Cut-Off timer ended the charge while the pack was still equalizing ; YamBMS now infers it, with no constant of its own - the voltage reference is the per-cell bulk setpoint (`bulk voltage / cell count`, so it follows the chemistry) and the spread reference is `bms_balance_trigger_voltage`, the threshold at which the pack's own balancer engages, which is 10 mV on a JK or a Seplos and 30 mV on an EG4, a pack reporting none at all simply never starting ; an external balancer keeps priority whenever one is online ; enabled by default for Seplos V3, Seplos V1/V2, EG4 LL v2 and JK RS485 DISPLAY, available for any other BMS, idea by [@haysdb](https://github.com/haysdb), see [changelog](documents/README/changelog/Changelog_Fake_Equalizing.md)
|
||||
* `bms_balance_trigger_voltage` is now a var on EG4 LL v2 and JK RS485 DISPLAY, which hardcoded it : declare your unit's actual balancing threshold at import, as Seplos already required. EG4 keeps `0.030` as its default, JK RS485 DISPLAY moves from `0.005` to `0.010` to match the JK factory default - note that this value also feeds 'Auto CVL'
|
||||
* Updated EG4 LL-V2 component to [v1.1.0](https://github.com/RAR/esphome-eg4-bms/releases/tag/v1.1.0) : fixes [issue 7](https://github.com/RAR/esphome-eg4-bms/issues/7), some EG4 LL-V2 units intermittently answer with a CRC-valid response whose register data is entirely zero, which was published as a real reading and collapsed SoC / voltage / capacity for one poll cycle ; those blocks are now rejected and no longer refresh the online tracker
|
||||
* PVbrain2 board split into two DevKitC-1 variants to follow the RGB LED / CAN TX pin swap between board revisions : `board_ESP32-S3_DevKitC-1_PVbrain2_LED-48.yaml` (DevKitC-1 V1.0, LED on GPIO 48 and CAN TX on 38) and `board_ESP32-S3_DevKitC-1_PVbrain2_LED-38.yaml` (V1.1, LED on GPIO 38 and CAN TX on 48), both including the common `board_ESP32-S3_DevKitC-1_PVbrain2.yaml` : include the one matching your board revision
|
||||
* New `loop_task_stack_size` option (8192/16384/32768) available on every board, to prevent stack overflow with a large number of BMS/entities, see [documentation](documents/README/LOOP_TASK_STACK.md)
|
||||
* Updated default PSRAM options for ESP-IDF 5.5+, see [documentation](documents/README/PSRAM_options.md)
|
||||
* Set esphome `min_version` to `2026.7.0`
|
||||
* Updated HA dashboards `1.8.0` for the new Cut-Off Cell Voltage, Charger Offset V., C-Rate and Auto CCL Current Taper entities
|
||||
* Fixed incorrect Max/Min Cell Voltage scaling (×100 instead of ×1000) sent on the CAN bus for the Deye PCS protocol
|
||||
* `secrets.yaml` template renamed to `secrets_example.yaml` (copy it to your own gitignored `secrets.yaml`, as documented in Installation_procedure.md)
|
||||
* Merged [PR 308](https://github.com/Sleeper85/esphome-yambms/pull/308) Check if Auto SoC Limit has reached its target
|
||||
* Merged [PR 303](https://github.com/Sleeper85/esphome-yambms/pull/303) Auto CCL Current Taper
|
||||
* Merged [PR 290](https://github.com/Sleeper85/esphome-yambms/pull/290) Add grace period to Auto EOC
|
||||
* New documentation :
|
||||
* [Charging_a_battery_with_CVL_and_CCL.md](documents/README/Charging_a_battery_with_CVL_and_CCL.md)
|
||||
* [Understanding_ESPHome_Modbus.md](documents/README/Understanding_ESPHome_Modbus.md)
|
||||
* [How_to_perform_a_PR_to_the_dev_branch.md](documents/README/How_to_perform_a_PR_to_the_dev_branch.md)
|
||||
* Merged [PR 308](https://github.com/Sleeper85/esphome-yambms/pull/308) Check if Auto SoC Limit has reached its target
|
||||
* Merged [PR 303](https://github.com/Sleeper85/esphome-yambms/pull/303) Auto CCL Current Taper
|
||||
* Merged [PR 290](https://github.com/Sleeper85/esphome-yambms/pull/290) Add grace period to Auto EOC
|
||||
|
||||
* [HA_entities_cleanup.md](documents/README/HA_entities_cleanup.md)
|
||||
|
||||
* YamBMS 1.7.0 :
|
||||
* Partial rewrite of `yambms_core` and merging of C++ code into a single lambda in several stages with increased datas control.
|
||||
|
||||
Reference in new issue
Block a user