> [!WARNING]
> The behavior described on this page is true up to the **first hardware version V19 shipped with firmware <= V19.10**.
> This behavior changes with **firmware > V19.10**.
> Using **DIP switch addresses 1 to 15** does not reliably guarantee that the **UART2 (RS485-2)** port protocol will be automatically configured to **001 - JK BMS RS485 Modbus V1.0**, which allows **YamBMS** to access BMS information.
> There is a known bug with the latest version of **JK firmware >= V19.10**.
> Using **DIP switch addresses 1 to 15** does not reliably guarantee that the **UART2 (RS485-2)** port protocol will be automatically configured to **001 - JK BMS RS485 Modbus V1.0**, which allows **YamBMS** to access BMS informations.
> YamBMS users have confirmed that it is possible to resolve this issue by performing an [Erase History Data](BMS_JK-PB.md#erase-history-data) from the JK app on a smartphone.
> The alternative solution is to use the **UART1 (RS485-1)** port configured with the **001 - JK BMS RS485 Modbus V1.0** protocol from the JK application.
> Downgrading to **V19.10** does not guarantee to correct this problem, [please read this information before downgrading](BMS_JK-PB.md#downgrading-to-1910).
> [!IMPORTANT]
> The most important thing for proper functioning of YamBMS is that **the voltage of your BMS is well calibrated**.
> YamBMS logic is based on the `min_cell_voltage` and `max_cell_voltage` voltages of your BMS.
@@ -209,25 +213,13 @@ On the `YamBMS` side, disabling the `EOC Timer` (which will end charging after m
![Image](../../images/BMS_JK-PB_SoC_100pct_Logic.png "Broadcasting JK-PB settings to all BMS")
## Downgrading to 19.10
## Erase History Data
Downgrading to **19.10** does **not definitely** fix the RS485‑2 issue in every situation, but it is the firmware version that most often restores the old, predictable behaviour on compatible V19 hardware.
The procedure below allows you to unblock the **UART2 (RS485-2)** port to restore normal behavior, depending on the DIP switch value :
* DIP switch **0** = protocol **015 - dedicated to the master BMS**
* DIP switches **1 to 15** = protocol **001 - JK BMS RS485 Modbus V1.0**
### What 19.10 usually fixes
- On early V19 units that originally ran something like 19.00–19.10, going back to 19.10 generally brings back the classic logic: DIP 0 → master protocol 015 on RS485‑2, DIP 1–15 → slave Modbus V1.0 on RS485‑2.
- Many users reporting RS485‑2 protocol problems on later 19.x builds have had the issue disappear or become much less erratic after flashing 19.10 on those same, early‑series V19 boards.
- If your BMS is from that first V19 hardware generation and has already worked correctly on 19.10 in the past, the probability that a downgrade will restore proper RS485‑2 auto‑selection is high, though never mathematically 100 %.
### Why it cannot be guaranteed
- JK has shipped several hardware revisions under the **V19** label (different comms boards, inverter‑style variants, added 4G, etc.), and not all of them were designed or tested for use with the older 19.10 firmware.
- On newer V19 hardware that came from the factory with a much later 19.x firmware, flashing 19.10 may or may not fully fix RS485‑2; in some cases it can introduce other quirks, because that firmware doesn’t **know** about all the newer options and mappings.
- There is no official statement from JK saying **downgrading to 19.10 on any V19 guarantees correct RS485‑2 behaviour**, so any downgrade remains at your own risk: you might regain proper RS485‑2 logic, but you might also revive older bugs or hit incompatibilities.
### Practical recommendation
- If you have an early V19 that you know worked fine with 19.10 before: downgrading is a reasonable, often effective attempt to get RS485‑2 back to the DIP‑driven behaviour.
- If your V19 is a later revision that never ran 19.10: do not assume a downgrade will solve everything; the safer path is usually to ignore RS485‑2 for Modbus and use RS485‑1 (UART1) explicitly set to **JK BMS RS485 Modbus V1.0** for all external reading, regardless of firmware.
So the honest answer is: downgrading to 19.10 often helps on compatible hardware, but it can’t be promised as a guaranteed fix for RS485‑2 on all V19 BMS units.
| 1. Generate a JK code | 2. Erase History Data | 3. Enter the code |
| --- | --- | --- |
| Go to [this page](https://mirofromdiro.github.io/JK-firmware-code/) to generate a new code valid for one hour. | In the JK smartphone app, click on the **Erase History Data** function. | Enter the **generated code** and then click **Verify**. |