Updated JK-PB readme with V19 warning and SoC 100% reset solution 1 and 2

This commit is contained in:
Sleeper85 committed 2025-11-16 15:13:14 +01:00
1 parent 66cbb93397
commit 5dc31f29c5
2 files changed
+45 -6

No files matched your search

+45 -6
View File
@@ -6,6 +6,13 @@
![GitHub forks](https://img.shields.io/github/forks/Sleeper85/esphome-yambms)
![GitHub watchers](https://img.shields.io/github/watchers/Sleeper85/esphome-yambms)
> [!WARNING]
> The behavior described on this page is true up to the **first hardware version V19 shipped with firmware <= V19.10**.
> This behavior changes with **firmware > V19.10**.
> Using **DIP switch addresses 1 to 15** does not reliably guarantee that the **UART2 (RS485-2)** port protocol will be automatically configured to **001 - JK BMS RS485 Modbus V1.0**, which allows **YamBMS** to access BMS information.
> The alternative solution is to use the **UART1 (RS485-1)** port configured with the **001 - JK BMS RS485 Modbus V1.0** protocol from the JK application.
> Downgrading to **V19.10** does not guarantee to correct this problem, [please read this information before downgrading](BMS_JK-PB#downgrading-to-1910).
> [!IMPORTANT]
> The most important thing for proper functioning of YamBMS is that **the voltage of your BMS is well calibrated**.
> YamBMS logic is based on the `min_cell_voltage` and `max_cell_voltage` voltages of your BMS.
@@ -20,7 +27,7 @@
## JK-PB BMS protocol
The datas from this BMS can be retrieved from the `RS485-2 (UART2)` network using the component [JK_RS485](https://github.com/txubelaxu/esphome-jk-bms/blob/main/components/jk_rs485_bms/README.md) of [@txubelaxu](https://github.com/txubelaxu).
The datas from this BMS can be retrieved from the `RS485-1 (UART1)` or `RS485-2 (UART2)` network using the component [JK_RS485](https://github.com/Sleeper85/esphome-components/tree/main/components) originally developed by [@txubelaxu](https://github.com/txubelaxu).
The BMS DIP switches must be set from `1` to `15` (server mode) and connected to each other using the `RS485-2` network available on the **two ports at the right ends**. `YamBMS` also connects to one of these two ports.
@@ -85,11 +92,11 @@ The following CAN protocols are supported on the CAN port:
> [!TIP]
> This solution only requires an ESP32 with a CAN transceiver and a RS485 transceiver.
You are free to choose the hardware you want, the list below are 3 easy to use examples :
You are free to choose the hardware you want, the list below are 3 easy to use examples of **ESP32-S3 with PSRAM** :
- `AtomS3` with the isolated `Atomic CAN base` and `RS485 unit`
- [`LilyGo T-Connect`, ESP32-S3 with 3x RS485 and 1x CAN](https://github.com/Xinyuan-LilyGO/T-Connect)
- [`LilyGo T-CAN485`, ESP32 with 1x RS485 and 1x CAN](https://github.com/Xinyuan-LilyGO/T-CAN485)
- [Waveshare ESP32-S3-RS485-CAN](https://www.waveshare.com/esp32-s3-rs485-can.htm), ESP32-S3 with 1x RS485 and 1x CAN
- [LilyGo T-Connect](https://github.com/Xinyuan-LilyGO/T-Connect), ESP32-S3 with 3x RS485 and 1x CAN
- [M5Stack AtomS3R](https://docs.m5stack.com/en/core/AtomS3R), ESP32-S3 with the isolated [Atomic CAN base](https://docs.m5stack.com/en/atom/Atomic%20CAN%20Base) and [RS485 unit](https://docs.m5stack.com/en/unit/iso485)
See the [documentation about supported hardware](Supported_devices.md).
@@ -175,6 +182,14 @@ When enabled, this function synchronizes the settings of all your BMS connected
> During the `Bulk` phase the YamBMS `SoC` cannot be more than `98%`.
> When the battery is fully charged, the average `SoC` of your BMS will be sent.
### Solution 1
The simplest solution is to disable the **Charging Float Mode** switch to disable the new **SoC 100% reset logic** described below in **Solution 2**. Your BMS will simply use the **SOC 100% V.** value, and the SoC will be reset to 100% as soon as a cell reaches this value.
![Image](../../images/BMS_JK-PB_Charging_Float_Mode.png "BMS JK-PB Charging Float Mode")
### Solution 2
The new `JK-PB` parameters `RCV` and `RCV timer` are not used by `YamBMS`, but you can adjust them to reach the `100%` faster, a little before `YamBMS` completes charging.
If you are instructing `YamBMS` to Bulk charge at `3.5V/cell`, configure the `JK-PB` parameters like this:
@@ -191,4 +206,28 @@ Then, when charging is complete before switching to `Float`, `YamBMS` will again
On the `YamBMS` side, disabling the `EOC Timer` (which will end charging after max `30min` in the `Cut-Off` phase without waiting for all `cells` to be `equalized`) will prolong charging until all your `cells` are `equalized` and the active balancer is no longer working for `60s`. This can give more time to the `JK-PB` to reset to `100%`.
![Image](../../images/BMS_JK-PB_SoC_100pct_Logic.png "Broadcasting JK-PB settings to all BMS")
![Image](../../images/BMS_JK-PB_SoC_100pct_Logic.png "Broadcasting JK-PB settings to all BMS")
## Downgrading to 19.10
Downgrading to **19.10** does **not definitely** fix the RS485‑2 issue in every situation, but it is the firmware version that most often restores the old, predictable behaviour on compatible V19 hardware.
### What 19.10 usually fixes
- On early V19 units that originally ran something like 19.00–19.10, going back to 19.10 generally brings back the classic logic: DIP 0 → master protocol 015 on RS485‑2, DIP 1–15 → slave Modbus V1.0 on RS485‑2.
- Many users reporting RS485‑2 protocol problems on later 19.x builds have had the issue disappear or become much less erratic after flashing 19.10 on those same, early‑series V19 boards.
- If your BMS is from that first V19 hardware generation and has already worked correctly on 19.10 in the past, the probability that a downgrade will restore proper RS485‑2 auto‑selection is high, though never mathematically 100 %.
### Why it cannot be guaranteed
- JK has shipped several hardware revisions under the **V19** label (different comms boards, inverter‑style variants, added 4G, etc.), and not all of them were designed or tested for use with the older 19.10 firmware.
- On newer V19 hardware that came from the factory with a much later 19.x firmware, flashing 19.10 may or may not fully fix RS485‑2; in some cases it can introduce other quirks, because that firmware doesn’t **know** about all the newer options and mappings.
- There is no official statement from JK saying **downgrading to 19.10 on any V19 guarantees correct RS485‑2 behaviour**, so any downgrade remains at your own risk: you might regain proper RS485‑2 logic, but you might also revive older bugs or hit incompatibilities.
### Practical recommendation
- If you have an early V19 that you know worked fine with 19.10 before: downgrading is a reasonable, often effective attempt to get RS485‑2 back to the DIP‑driven behaviour.
- If your V19 is a later revision that never ran 19.10: do not assume a downgrade will solve everything; the safer path is usually to ignore RS485‑2 for Modbus and use RS485‑1 (UART1) explicitly set to **JK BMS RS485 Modbus V1.0** for all external reading, regardless of firmware.
So the honest answer is: downgrading to 19.10 often helps on compatible hardware, but it can’t be promised as a guaranteed fix for RS485‑2 on all V19 BMS units.