Fixed issue #195

This commit is contained in:
Sleeper85 committed 2026-02-07 13:54:25 +01:00
1 parent 29a0fe1dee
commit 6836806bb0
1 file changed
+31 -9
+31 -9
View File
@@ -1,4 +1,4 @@
# Updated : 2026.02.04
# Updated : 2026.02.07
# Version : 1.7.0
# GitHub : https://github.com/Sleeper85/esphome-yambms
@@ -758,7 +758,7 @@ interval:
// that these are not random/erroneous/false readings of the BMS
if (cutoff_counter > 4)
{
ESP_LOGI("yambms", "Entering the Cut-Off phase...");
ESP_LOGD("yambms_debug", "Entering the Cut-Off phase...");
// Cut-Off : the end of charging is near
id(${yambms_id}_var_charge_status) = "Cut-Off";
@@ -813,10 +813,11 @@ interval:
}
}
// Charging not allowed (BMS or YamBMS)
else if ((id(${yambms_id}_var_charge_status) != "Init") && (id(${yambms_id}_var_bms_charging_logic) == false))
else if (id(${yambms_id}_var_bms_charging_logic) == true)
{
id(${yambms_id}_var_charge_status) = "Wait";
if (!id(${yambms_id}_switch_charging).state) id(${yambms_id}_var_charge_status) = "Wait";
}
else id(${yambms_id}_var_charge_status) = "Wait";
// Publish the sensor
id(${yambms_id}_charging_status).publish_state(id(${yambms_id}_var_charge_status));
@@ -905,10 +906,20 @@ interval:
requested_charge_current = round(id(${yambms_id}_max_charge_current).state + auto_limit);
if (requested_charge_current < 0) requested_charge_current = 0;
}
// Publish the sensor
id(${yambms_id}_requested_charge_current).publish_state(requested_charge_current);
if (requested_charge_current > 0) id(${yambms_id}_var_requested_ccl_init) = true;
id(${yambms_id}_var_charge_current_step)++;
if (id(${yambms_id}_switch_charging).state) {
ESP_LOGD("yambms_debug", "Charging switch : true");
if (requested_charge_current > 0) id(${yambms_id}_var_requested_ccl_init) = true;
}
else {
ESP_LOGD("yambms_debug", "Charging switch : false");
id(${yambms_id}_var_requested_ccl_init) = true;
}
id(${yambms_id}_var_charge_current_step)++;
}
// +-----------------------------------------------+
@@ -931,9 +942,20 @@ interval:
requested_discharge_current = round(id(${yambms_id}_max_discharge_current).state + auto_limit);
if (requested_discharge_current < 0) requested_discharge_current = 0;
}
// Publish the sensor
id(${yambms_id}_requested_discharge_current).publish_state(requested_discharge_current);
if (requested_discharge_current > 0) id(${yambms_id}_var_requested_dcl_init) = true;
if (id(${yambms_id}_switch_discharging).state) {
ESP_LOGD("yambms_debug", "Discharging switch : true");
if (requested_discharge_current > 0) id(${yambms_id}_var_requested_dcl_init) = true;
}
else {
ESP_LOGD("yambms_debug", "Discharging switch : false");
id(${yambms_id}_var_requested_dcl_init) = true;
}
id(${yambms_id}_var_discharge_current_step)++;
}
@@ -973,8 +995,8 @@ interval:
if (id(${yambms_id}_discharging_instruction).has_state())
{
bool discharging_instruction = id(${yambms_id}_discharging_instruction).state;
if (discharging_instruction == true) ESP_LOGD("yambms_debug", "Discharging instruction : true");
else ESP_LOGD("yambms_debug", "Discharging instruction : false");
if (discharging_instruction == true) ESP_LOGD("yambms_debug", "Discharging instruction : true");
else ESP_LOGD("yambms_debug", "Discharging instruction : false");
}
if (id(${yambms_id}_requested_charge_voltage).has_state()) ESP_LOGD("yambms_debug", "Requested CVL : %f V", id(${yambms_id}_requested_charge_voltage).state);
if (id(${yambms_id}_requested_discharge_voltage).has_state()) ESP_LOGD("yambms_debug", "Requested DVL : %f V", id(${yambms_id}_requested_discharge_voltage).state);