YamBMS 1.5.5 (fix Force Float charge status)
This commit is contained in:
1 parent
3b490821fe
commit
7815119183
2 files changed
+10
-5
No files matched your search
@@ -81,6 +81,10 @@ globals:
|
||||
type: bool
|
||||
restore_value: no
|
||||
initial_value: 'false'
|
||||
- id: ${yambms_id}_force_float
|
||||
type: bool
|
||||
restore_value: no
|
||||
initial_value: 'false'
|
||||
- id: ${yambms_id}_charge_status
|
||||
type: std::string
|
||||
restore_value: no
|
||||
@@ -545,6 +549,8 @@ text_sensor:
|
||||
else if ((id(${yambms_id}_charge_status) == "Float") & (!id(${yambms_id}_switch_float).state)) id(${yambms_id}_charge_status) = "EOC";
|
||||
// No Force Bulk => Wait
|
||||
else if ((id(${yambms_id}_charge_status) == "Force Bulk") & (!id(${yambms_id}_switch_force_bulk).state)) id(${yambms_id}_charge_status) = "Wait";
|
||||
// Force Float
|
||||
else if (id(${yambms_id}_force_float) == true) id(${yambms_id}_charge_status) = "Float";
|
||||
|
||||
// +-----------------------------------------------+
|
||||
// | Charging allowed (BMS and YamBMS) |
|
||||
|
||||
+4
-5
@@ -26,17 +26,16 @@ switch:
|
||||
entity_category: config
|
||||
|
||||
interval:
|
||||
# Force Float
|
||||
- interval: ${yambms_update_interval}
|
||||
then:
|
||||
- lambda: |-
|
||||
// Force Float => Float
|
||||
if (id(${yambms_id}_switch_force_float).state) id(${yambms_id}_charge_status) = "Float";
|
||||
// Force Float
|
||||
if (id(${yambms_id}_switch_force_float).state) id(${yambms_id}_force_float) = true;
|
||||
else id(${yambms_id}_force_float) = false;
|
||||
|
||||
# Setup min/max value
|
||||
- interval: 24h # 60s
|
||||
then:
|
||||
- lambda: |-
|
||||
// Float V.
|
||||
// Set min/max Float slider
|
||||
id(${yambms_id}_float_voltage).traits.set_min_value(${yambms_cell_count} * 3.125);
|
||||
id(${yambms_id}_float_voltage).traits.set_max_value(${yambms_cell_count} * 3.375);
|
||||
Reference in new issue