Dual counter for entering and exiting the Cut-Off phase

This commit is contained in:
Sleeper85 committed 2026-01-13 18:57:42 +01:00
1 parent daf2e4fec3
commit 78e8b21977
1 file changed
+11 -2
+11 -2
View File
@@ -1,4 +1,4 @@
# Updated : 2025.12.30
# Updated : 2026.01.13
# Version : 1.6.0
# GitHub : https://github.com/Sleeper85/esphome-yambms
@@ -641,6 +641,7 @@ text_sensor:
float current = id(${yambms_id}_current).state;
float cutoff_resistance = ((cv_max - cv_min) / id(${yambms_id}_battery_capacity).state / 0.05);
static int cutoff_counter = 0;
static int bulk_counter = 0;
// +-----------------------------------------------+
// | Cut-Off Charging Logic |
@@ -650,9 +651,15 @@ text_sensor:
float cutoff_voltage = (max_cell_v - cutoff_resistance * current);
if(cutoff_voltage > cv_min)
{
cutoff_counter++;
bulk_counter = 0;
}
else
{
bulk_counter++;
cutoff_counter = 0;
}
// Entering the Cut-Off phase
// The criteria check must succeed 5 times in a row to ensure
@@ -686,7 +693,9 @@ text_sensor:
id(${yambms_id}_script_cutoff_timer).execute();
}
// Continue charging
else
// The criteria check must succeed 5 times in a row to ensure
// that these are not random/erroneous/false readings of the BMS
else if (bulk_counter > 4)
{
// Stop timer
if (id(${yambms_id}_script_eoc_timer).is_running()) id(${yambms_id}_script_eoc_timer).stop();