@@ -15,13 +15,15 @@
|
||||
|
||||
| ESPHome application to monitor BMS and communicate with inverters<br>supporting CAN bus protocol compatible with Pylontech, GoodWe, SMA,<br>Victron or Luxpower (EG4). | <a href="https://www.buymeacoffee.com/Sleeper85" target="_blank"><img src="https://cdn.buymeacoffee.com/buttons/v2/default-yellow.png" alt="Buy Me A Coffee" style="height: 60px !important;width: 217px !important;" ></a> |
|
||||
| :--- | --- |
|
||||
| **Note: Pylontech uses 15S/48V and many others uses 16S/51.2V !**<br><br>Other battery profiles that utilise the **`PYLON`** protocol with different cell counts<br>may also work, e.g. Alpha Ess Smile, BYD Battery-Box LV Flex Lite.<br>Select the correct battery profile in the inverter to match your battery pack !<br>The **`ESP32`** communicates with the BMS using the **`BLE / UART / RS485`**<br>protocol and then sends the CAN bus data to the inverter via the<br>[CAN bus transceiver](documents/README/Supported_devices.md#supported-can-bus-transceiver). | <a href="https://www.buymeacoffee.com/Sleeper85" target="_blank"><img src="images/BMC_QR.png" alt="Buy Me A Coffee" style="height: 217px !important;width: 217px !important;" ></a> |
|
||||
| **Note: Pylontech uses 15S/48V and many others uses 16S/51.2V !**<br><br>Other battery profiles that utilise the **`PYLON`** protocol with different cell counts<br>may also work, e.g. Alpha Ess Smile, BYD Battery-Box LV Flex Lite.<br>Select the correct battery profile in the inverter to match your battery pack !<br>The **`ESP32`** communicates with the BMS using the **`BLE / UART / RS485`**<br>protocol and then sends the CAN bus frames to the inverter via the<br>[CAN bus transceiver](documents/README/Supported_devices.md#supported-can-bus-transceiver). | <a href="https://www.buymeacoffee.com/Sleeper85" target="_blank"><img src="images/BMC_QR.png" alt="Buy Me A Coffee" style="height: 217px !important;width: 217px !important;" ></a> |
|
||||
|
||||
**Sends over CAN bus to inverter:**
|
||||
- Battery Voltage
|
||||
- Battery Current (+charge, -discharge)
|
||||
- State of Charge (SOC)
|
||||
- State of health (SOH)
|
||||
- [State of Charge (SoC)](documents/README/YamBMS_behavior.md#state-of-charge) **`SoC 100% will be sent to your inverter only when the battery is fully charged`**
|
||||
- State of Health (SoH)
|
||||
- Max cell V. and ID
|
||||
- Min cell V. and ID
|
||||
- BMS temperature
|
||||
- Charging voltage
|
||||
- Charging max amps
|
||||
@@ -30,8 +32,8 @@
|
||||
- Battery name
|
||||
- Alarms: Cell over/under voltage, Charge/discharge over current, High/low Temp, BMS fault
|
||||
|
||||
**Note:** this code support `multi-BMS` connection per inverter with a `single ESP32` and should work with inverters that support<br>
|
||||
the CAN bus protocol `PYLON`, `SMA`, `Victron` or `LuxPower` (EG4). I'm only testing it with my `Deye SUN-6K-SG03-LP1-EU` inverter.<br>
|
||||
**Note:** this code support `multi-BMS` and `multi-shunt` connection per inverter with a `single ESP32` and should work with inverters that support the CAN bus protocol `PYLON`, `SMA`, `Victron` or `LuxPower` (EG4). I'm only testing it with my `Deye SUN-6K-SG03-LP1-EU` inverter.
|
||||
|
||||
**This project is still in development and testing...<br>**
|
||||
|
||||
[Dedicated topic on DIY Solar Forum](https://diysolarforum.com/threads/yambms-jk-bms-can-with-new-cut-off-charging-logic-open-source.79325/)
|
||||
|
||||
@@ -37,6 +37,51 @@ Combine condition :
|
||||
|
||||
If one of these three conditions is not met, the BMS is automatically decombined.
|
||||
|
||||
## State of Charge
|
||||
|
||||
The `SoC` is slightly manipulated before reaching `0%` or `100%`.
|
||||
SoC `100%` will be sent to your inverter only when the battery is `fully charged` (useful for some inverters stopping charging when the SoC reaches 100%).
|
||||
|
||||
SoC behavior:
|
||||
1) If `min_cell_v <= cell_uvpr` SoC 0% is sent
|
||||
2) Else if `SOC < 1%` SoC 2% is sent (false 0% sending 2%)
|
||||
3) Else if `SOC < 99%` real SoC is sent
|
||||
4) Else if `the battery is fully charged` real SoC is sent
|
||||
5) Else SoC `98%` is sent
|
||||
|
||||
## CAN bus link
|
||||
|
||||
For the CAN bus link to be established with your inverter, the two conditions below must be met:
|
||||
1) At least one BMS is in service (the number of combined BMS must be `> 0`)
|
||||
2) Your inverter sends an `ACK 0x305` every `1s` (the link will be faulty if no ACK is received for 5s)
|
||||
|
||||
If these conditions are not met, the application waits `120s` before trying to connect again.
|
||||
|
||||
### Extra infos
|
||||
|
||||
Sending CAN frames continues without an inverter connected is problematic and will lead to ESP32 crash.
|
||||
|
||||
During boot the CAN bus links are activated directly if at least one BMS is combined and the inverter responds to the sending of CAN frames within a `5s` delay.
|
||||
This `5s` delay represents the time during which the link is valid, this timer is reset each time an `ACK 0x305` is received from the inverter.
|
||||
This `5s` delay can be modified in the configuration when importing the canbus package.
|
||||
|
||||
```YAML
|
||||
canbus1: !include
|
||||
file: packages/yambms/yambms_canbus.yaml
|
||||
vars:
|
||||
# YamBMS ID
|
||||
yambms_id: 'yambms1'
|
||||
# CANBUS vars
|
||||
canbus_id: 'canbus1'
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_node1'
|
||||
canbus_light_id: 'esp_light'
|
||||
# The CANBUS link will be considered down if no response from the inverter (ID 0x305) for 5s
|
||||
canbus_link_timer: '5'
|
||||
```
|
||||
|
||||
If the inverter does not respond with an `ACK 0x305` within this `5s` delay the sending of CAN frames is paused for `120s` this delay cannot be modified when importing the canbus package but you can modify it in the code if you need to.
|
||||
|
||||
## BMS alarms
|
||||
|
||||
> [!IMPORTANT]
|
||||
@@ -50,12 +95,4 @@ As long as at least one BMS is working normally the system will continue to work
|
||||
YamBMS will display BMS alarms as `Warning`.
|
||||
|
||||
If all BMS are in alarm, they are all uncombined and in this case the sending of instructions on the `CAN bus` is also stopped.
|
||||
YamBMS will display BMS alarms as `Alarm`.
|
||||
|
||||
## CAN bus link
|
||||
|
||||
For the CAN bus link to be established with your inverter, the two conditions below must be met:
|
||||
1) At least one BMS is in service (the number of combined BMS must be `> 0`)
|
||||
2) Your inverter sends an `ACK 0x305` every `1s` (the link will be faulty if no ACK is received for 5s)
|
||||
|
||||
If these conditions are not met, the application waits `120s` before trying to connect again.
|
||||
YamBMS will display BMS alarms as `Alarm`.
|
||||