@@ -15,13 +15,15 @@
| ESPHome application to monitor BMS and communicate with inverters<br>supporting CAN bus protocol compatible with Pylontech, GoodWe, SMA,<br>Victron or Luxpower (EG4). | <a href="https://www.buymeacoffee.com/Sleeper85" target="_blank"><img src="https://cdn.buymeacoffee.com/buttons/v2/default-yellow.png" alt="Buy Me A Coffee" style="height: 60px !important;width: 217px !important;" ></a> |
| :--- | --- |
| **Note: Pylontech uses 15S/48V and many others uses 16S/51.2V !**<br><br>Other battery profiles that utilise the **`PYLON`** protocol with different cell counts<br>may also work, e.g. Alpha Ess Smile, BYD Battery-Box LV Flex Lite.<br>Select the correct battery profile in the inverter to match your battery pack !<br>The **`ESP32`** communicates with the BMS using the **`BLE / UART / RS485`**<br>protocol and then sends the CAN bus data to the inverter via the<br>[CAN bus transceiver](documents/README/Supported_devices.md#supported-can-bus-transceiver). | <a href="https://www.buymeacoffee.com/Sleeper85" target="_blank"><img src="images/BMC_QR.png" alt="Buy Me A Coffee" style="height: 217px !important;width: 217px !important;" ></a> |
| **Note: Pylontech uses 15S/48V and many others uses 16S/51.2V !**<br><br>Other battery profiles that utilise the **`PYLON`** protocol with different cell counts<br>may also work, e.g. Alpha Ess Smile, BYD Battery-Box LV Flex Lite.<br>Select the correct battery profile in the inverter to match your battery pack !<br>The **`ESP32`** communicates with the BMS using the **`BLE / UART / RS485`**<br>protocol and then sends the CAN bus frames to the inverter via the<br>[CAN bus transceiver](documents/README/Supported_devices.md#supported-can-bus-transceiver). | <a href="https://www.buymeacoffee.com/Sleeper85" target="_blank"><img src="images/BMC_QR.png" alt="Buy Me A Coffee" style="height: 217px !important;width: 217px !important;" ></a> |
**Sends over CAN bus to inverter:**
- Battery Voltage
- Battery Current (+charge, -discharge)
- State of Charge (SOC)
- State of health (SOH)
- [State of Charge (SoC)](documents/README/YamBMS_behavior.md#state-of-charge) **`SoC 100% will be sent to your inverter only when the battery is fully charged`**
- State of Health (SoH)
- Max cell V. and ID
- Min cell V. and ID
- BMS temperature
- Charging voltage
- Charging max amps
@@ -30,8 +32,8 @@
- Battery name
- Alarms: Cell over/under voltage, Charge/discharge over current, High/low Temp, BMS fault
**Note:** this code support `multi-BMS` connection per inverter with a `single ESP32` and should work with inverters that support<br>
the CAN bus protocol `PYLON`, `SMA`, `Victron` or `LuxPower` (EG4). I'm only testing it with my `Deye SUN-6K-SG03-LP1-EU` inverter.<br>
**Note:** this code support `multi-BMS` and `multi-shunt` connection per inverter with a `single ESP32` and should work with inverters that support the CAN bus protocol `PYLON`, `SMA`, `Victron` or `LuxPower` (EG4). I'm only testing it with my `Deye SUN-6K-SG03-LP1-EU` inverter.
**This project is still in development and testing...<br>**
[Dedicated topic on DIY Solar Forum](https://diysolarforum.com/threads/yambms-jk-bms-can-with-new-cut-off-charging-logic-open-source.79325/)
+46 -9
View File
@@ -37,6 +37,51 @@ Combine condition :
If one of these three conditions is not met, the BMS is automatically decombined.
## State of Charge
The `SoC` is slightly manipulated before reaching `0%` or `100%`.
SoC `100%` will be sent to your inverter only when the battery is `fully charged` (useful for some inverters stopping charging when the SoC reaches 100%).
SoC behavior:
1) If `min_cell_v <= cell_uvpr` SoC 0% is sent
2) Else if `SOC < 1%` SoC 2% is sent (false 0% sending 2%)
3) Else if `SOC < 99%` real SoC is sent
4) Else if `the battery is fully charged` real SoC is sent
5) Else SoC `98%` is sent
## CAN bus link
For the CAN bus link to be established with your inverter, the two conditions below must be met:
1) At least one BMS is in service (the number of combined BMS must be `> 0`)
2) Your inverter sends an `ACK 0x305` every `1s` (the link will be faulty if no ACK is received for 5s)
If these conditions are not met, the application waits `120s` before trying to connect again.
### Extra infos
Sending CAN frames continues without an inverter connected is problematic and will lead to ESP32 crash.
During boot the CAN bus links are activated directly if at least one BMS is combined and the inverter responds to the sending of CAN frames within a `5s` delay.
This `5s` delay represents the time during which the link is valid, this timer is reset each time an `ACK 0x305` is received from the inverter.
This `5s` delay can be modified in the configuration when importing the canbus package.
```YAML
canbus1: !include
file: packages/yambms/yambms_canbus.yaml
vars:
# YamBMS ID
yambms_id: 'yambms1'
# CANBUS vars
canbus_id: 'canbus1'
canbus_name: 'CANBUS 1'
canbus_node_id: 'canbus_node1'
canbus_light_id: 'esp_light'
# The CANBUS link will be considered down if no response from the inverter (ID 0x305) for 5s
canbus_link_timer: '5'
```
If the inverter does not respond with an `ACK 0x305` within this `5s` delay the sending of CAN frames is paused for `120s` this delay cannot be modified when importing the canbus package but you can modify it in the code if you need to.
## BMS alarms
> [!IMPORTANT]
@@ -50,12 +95,4 @@ As long as at least one BMS is working normally the system will continue to work
YamBMS will display BMS alarms as `Warning`.
If all BMS are in alarm, they are all uncombined and in this case the sending of instructions on the `CAN bus` is also stopped.
YamBMS will display BMS alarms as `Alarm`.
## CAN bus link
For the CAN bus link to be established with your inverter, the two conditions below must be met:
1) At least one BMS is in service (the number of combined BMS must be `> 0`)
2) Your inverter sends an `ACK 0x305` every `1s` (the link will be faulty if no ACK is received for 5s)
If these conditions are not met, the application waits `120s` before trying to connect again.
YamBMS will display BMS alarms as `Alarm`.