Improve Deye support (#337)

* Fix Deye power update interval
* Keep batteries the report CCL/DCL 0A

A battery that reports a charge limit (CCL) or discharge limit (DCL) of 0 A now stays in the combine. Before, a full Deye at 0 A CCL, or an empty one at 0 A DCL, dropped out of capacity, SoC and the totals.

- Missing values are still caught: a CCL or DCL with no value yet still fails >= 0, because comparisons with NaN are always false.
- No effect on the limits: CCL and DCL are added up, so a battery at 0 A adds 0 A to the total.
- All BMS models are affected

https://github.com/Sleeper85/esphome-yambms/issues/335
This commit is contained in:
Sebastian authored and Sleeper85 committed 2026-11-08 23:08:33 +01:00
1 parent 0d56db9849
commit c7e498d5ca
3 files changed
+13 -7

No files matched your search

+3 -3
View File
@@ -1,4 +1,4 @@
# Updated : 2026.08.26
# Updated : 2026.11.02
# Version : 1.8.0
# GitHub : https://github.com/Sleeper85/esphome-yambms
@@ -61,8 +61,8 @@ binary_sensor:
(id(bms${bms_id}_battery_capacity).state > 0) &&
(id(bms${bms_id}_battery_capacity_remaining).has_state()) &&
(id(bms${bms_id}_charging_cycles).has_state()) &&
(id(bms${bms_id}_max_charge_current).state > 0) &&
(id(bms${bms_id}_max_discharge_current).state > 0) &&
(id(bms${bms_id}_max_charge_current).state >= 0) &&
(id(bms${bms_id}_max_discharge_current).state >= 0) &&
(id(bms${bms_id}_min_cell_voltage).has_state()) &&
(id(bms${bms_id}_max_cell_voltage).has_state()) &&
(id(bms${bms_id}_min_voltage_cell).has_state()) &&
@@ -1,5 +1,5 @@
# Updated : 2026.10.18
# Version : 1.2.3
# Updated : 2026.11.02
# Version : 1.2.4
# GitHub : https://github.com/GHswitt/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -335,6 +335,7 @@ sensor:
id: bms${bms_id}_power
device_id: bms_${bms_id}
name: "battery power"
update_interval: ${bms_update_interval}
unit_of_measurement: 'W'
device_class: 'power'
state_class: 'measurement'
@@ -349,6 +350,7 @@ sensor:
# Charging power: Calculated from voltage and current
- platform: template
name: "battery power charging"
update_interval: ${bms_update_interval}
id: bms${bms_id}_charging_power
device_id: bms_${bms_id}
unit_of_measurement: 'W'
@@ -366,6 +368,7 @@ sensor:
# Discharging power: Calculated from voltage and current
- platform: template
name: "battery power discharging"
update_interval: ${bms_update_interval}
id: bms${bms_id}_discharging_power
device_id: bms_${bms_id}
unit_of_measurement: 'W'
@@ -1,5 +1,5 @@
# Updated : 2026.10.18
# Version : 1.2.3
# Updated : 2026.11.02
# Version : 1.2.4
# GitHub : https://github.com/GHswitt/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -192,6 +192,7 @@ sensor:
id: bms${bms_id}_power
device_id: bms_${bms_id}
name: "battery power"
update_interval: ${bms_update_interval}
unit_of_measurement: 'W'
device_class: 'power'
state_class: 'measurement'
@@ -206,6 +207,7 @@ sensor:
# Charging power: Calculated from voltage and current
- platform: template
name: "battery power charging"
update_interval: ${bms_update_interval}
id: bms${bms_id}_charging_power
device_id: bms_${bms_id}
unit_of_measurement: 'W'
@@ -223,6 +225,7 @@ sensor:
# Discharging power: Calculated from voltage and current
- platform: template
name: "battery power discharging"
update_interval: ${bms_update_interval}
id: bms${bms_id}_discharging_power
device_id: bms_${bms_id}
unit_of_measurement: 'W'