Docs: Rewrite the inverter brand and protocol section

Lead with the three setup steps: select the inverter brand, leave
Protocol on Automatic, then configure the inverter from the dashboard.
Forcing a protocol moves to its own subsection, as the exception it is.

The screenshot now shows the brand and protocol selects and the active
protocol card, and replaces YamBMS_CANBUS_Protocol.png.
This commit is contained in:
Sleeper85 committed 2026-11-08 23:08:34 +01:00
1 parent cb9638653d
commit cab5a63e0e
3 files changed
+35 -18

No files matched your search

+35 -18
View File
@@ -6,29 +6,35 @@
![GitHub forks](https://img.shields.io/github/forks/Sleeper85/esphome-yambms)
![GitHub watchers](https://img.shields.io/github/watchers/Sleeper85/esphome-yambms)
## CAN protocol
## Inverter Brand and Protocol
> [!IMPORTANT]
> You need to check if your inverter model is on the list of [supported inverters](Supported_devices.md#supported-inverter). In any case it must support one of the following `CAN` bus protocols.
> Select your inverter brand and leave `Protocol` on `Automatic`. If your inverter is supported,
> the dashboard then shows how to configure it: the battery mode to set on the inverter and any
> note specific to your brand.
![Image](../../images/YamBMS_CANBUS_Protocol.png "YamBMS_CANBUS_Protocol")
![Image](../../images/YamBMS_Inverter_Brand_and_Protocol.png "YamBMS_Inverter_Brand_and_Protocol")
Select your inverter brand with the `Inverter brand` select and YamBMS applies the protocol
below, as long as the `Protocol` select is left on `Automatic`. Choosing a protocol explicitly
always takes priority over the brand, so an inverter that does not follow the usual mapping can
still be driven.
### Setup in three steps
As long as the brand is `Not defined` and the protocol is `Automatic`, **nothing is sent on the
bus**: this is deliberate, so that a node is never left talking a protocol nobody chose. The
`Inverter link protocol` diagnostic entity reports what the link is actually doing.
1. **Set `Inverter brand`** to the brand of your inverter. If it is not in the list, select
`Other` and see [Forcing a protocol](#forcing-a-protocol).
2. **Leave `Protocol` on `Automatic`.** YamBMS selects the best protocol known for your brand,
following the [mapping below](#brand-to-protocol-mapping).
3. **Configure your inverter** as shown in the `Inverter active protocol` card: set the battery
mode it gives you, and read the note if there is one.
Don't forget to configure your inverter for the protocol in use — the `Inverter battery mode`
diagnostic entity gives you the setting to look for, and `Note` reports what is specific to your
brand.
As long as the brand is `Not defined`, nothing is sent on the bus and your inverter reports a
BMS communication fault. This is deliberate, so that a node is never left talking a protocol
nobody chose.
The mapping below is a sensible default, not a rule: a manufacturer may use a different protocol
depending on the model. Other configurations are possible, don't hesitate to communicate what
works well for you.
The inverter models confirmed by users are listed in [supported inverters](Supported_devices.md#supported-inverters).
### Brand to protocol mapping
In `Automatic`, YamBMS applies the protocol below for your brand. This mapping is a sensible
default, not a rule: a manufacturer may use a different protocol depending on the model. Don't
hesitate to share what works well for you.
| Inverter | Battery mode | Bus | Protocol |
| --- | --- | --- | --- |
@@ -60,14 +66,25 @@ Any other brand of the list, or a listed brand on the other bus, uses `PYLON V2`
and the protocol compiled on the node on RS485. Such a combination has not been validated, and the
`Note` entity says so.
### RS485
On RS485 the protocol is chosen in your YAML with `rs485_protocol` (`pylon` or `voltronic`), and the
brand does not change it. `LIB` only works with `Voltronic` and `MPP Solar`: in `Automatic`, a node
compiled for `LIB` stays silent for any other brand. Rebranded Voltronic inverters must select
`Voltronic`. The protocols offered by parameter `05` depend on the inverter firmware, see its user
manual.
A few couples outside the default mapping are known to work as well, and YamBMS reports the right
battery mode for them too: `EG4` on `PYLON V1` (Lithium 2, 6000XP only) and `Solis` on `PYLON V2`
### Forcing a protocol
Only change `Protocol` if your inverter does not communicate with the automatic choice, or if you
selected `Other`. A forced protocol always takes priority over the brand, so an inverter that does
not follow the usual mapping can still be driven. `Disabled` turns the link off without raising a
fault.
The `Inverter link protocol` diagnostic entity always reports what the link is actually doing.
A few couples outside the default mapping are known to work, and YamBMS reports the right battery
mode for them too: `EG4` on `PYLON V1` (Lithium 2, 6000XP only) and `Solis` on `PYLON V2`
(Pylon LV, requires a 3.3V CAN transceiver).