ESPHome 2026.11 makes `relation` a required option for every entry under
`esphome: devices:`, and 2026.10 rejects that key. Both changes have to
land together, so raise min_version to 2026.11.0 in the same commit.
Use `relation: via` on all ten device declarations (BMS, sniffer, shunt,
balancer, Deye stack, board, YamBMS instance, CAN and RS485 links). It is
the value the API assumed before the key existed, so Home Assistant keeps
showing the devices exactly as before. `child` would fit the board, the
YamBMS instance and the inverter links better, but it is left for later:
a Home Assistant release that reads the field without supporting `child`
drops those devices and their entities.
Docs: ESPHome 2026.11.0 in README and Installation_procedure (which still
said 2025.11.0), Design_decisions no longer equates min_version with the
flow_control requirement, and Coding_conventions documents the
`relation: via` rule.
Each package now imports its UART from its *_uart_id var and keeps its own baud
rate key. WK2168 channels work the same way, uart_flow_control_pin replaces the
flow control include, and min_version moves to 2026.10.0. Breaking change.
BREAKING CHANGE: both inverter link selects are renamed, so their stored value is
reset. The link stays inactive until an inverter brand is selected. See
documents/README/changelog/Changelog_Inverter_brand_and_protocol.md
New `Inverter brand` select (16 brands) and reworked `Protocol` select, now
defaulting to `Automatic`. Selecting the brand is enough, the protocol follows;
an explicit protocol still takes priority over the brand.
The protocol is resolved once, at boot and on every select change, into
`canbus${canbus_id}_active_protocol` / `rs485${rs485_id}_active_protocol`.
Everything else reads that integer instead of dispatching on `active_index()`,
where `== 5` meant LuxPower purely by convention of the option order.
New shared `yambms_inverter_registry.yaml`: protocol dictionary (`YB_PROTO_*`),
brand to protocol mapping, and the battery mode and note of each couple.
Removed the `YamBMS name` select: the manufacturer name sent on CAN frame 0x35E
now derives from the protocol in use, which is what `Automatic` already did.
Removed the `canbus_extended_ack` substitution: both the 11-bit and the 29-bit
ACK triggers are registered, so the Schneider XW Pro needs no configuration.
Renamed CAN `PYLON 1.2` to `PYLON V1` and RS485 `Pylontech` to `PYLON`.
New per-link diagnostics `Inverter link protocol`, `Inverter battery mode` and
`Note`, with a markdown card in the dashboards, alongside a system fault card.
Telemetry: `comm_bus` / `comm_protocol` replaced by `inverter_brand`,
`inverter_bus`, `inverter_protocol` and `inverter_protocol_source`, one slot per
declared link instead of a single value overwritten by the last one.
RS485 packages split: `yambms_rs485.yaml` is the entry point carrying the selects,
`yambms_rs485_pylon.yaml` the protocol implementation. The baud rate is applied
with `set_baud_rate()` + `load_settings()` instead of extending the uart
component, so boards using a UART expander no longer need their own include.
Fixes:
- the CAN bus kept re-emitting the last frame every 100 ms when the protocol was
set to `Disabled` at runtime
- the RS485 link kept answering the inverter with stale data on `Disabled`, the
proxy sensors it reads are now invalidated
- a `Disabled` link no longer lights the fault LED, it is unregistered from the
fault registry instead of being reported as failing
- the reported bus and protocol were overwritten when a node declares several
inverter links
- changing the protocol restarts the CAN frames immediately instead of waiting up
to 30 s for the next retry tick
- update and telemetry are now gated independently by substitution;
var_service and its Update service switch are removed
- the uptime text sensor is published by its source instead of polling
it, which fixes the 24855d readings that reached the telemetry, and
the raw seconds are now sent instead of the formatted string
- the MAC address is replaced by a salted SHA-256, derived identically
server side so no pairing window is needed
bms_base_charging_cycles.yaml coerced a NaN raw reading to 0 before adding
the user offset, instead of letting NaN propagate like the sensors fixed
in dee203e4 ("Sensors published to NAN when no BMS is combined"). *_raw is
NaN until the first trusted BMS frame arrives after a reboot, so both
`charging cycles` and `total charging cycle capacity` published a literal
0 during that transient - with `state_class: total`, that 0 also landed
in Home Assistant's long-term statistics.
Fix is to drop the two `if (isnan(...)) = 0;` coercions and let
`NaN + offset == NaN` propagate, so both sensors go unavailable through
the transient instead of reporting 0.
Both sensors also moved from `or: [throttle: 10s, delta: 1]` to the
NaN-safe rate-limit filter already used throughout yambms_core.yaml, since
the built-in `delta` filter drops a NaN transition without updating its
reference and would otherwise freeze the sensor on its last value for up
to 10s.
That filter is extracted from yambms_core.yaml into
packages/base/device_base.yaml, which every node loads via its board_*.yaml
regardless of whether it runs the YamBMS engine - unlike yambms_core.yaml,
which is absent from a multi-node Modbus-server node that only exposes
BMS/Shunt packages. Renamed yambms_rate_limit_filter to rate_limit_filter
now that it is no longer engine-specific.
This adds 'yambms_max_inverter_charge_current' and 'yambms_max_inverter_discharge_current' substitutions. They are used to restrict the range of the charge/discharge current for easier control when the battery currents are much higher than the inverter currents.