* Update EG4 LL-V2 component to v1.1.0
FixesRAR/esphome-eg4-bms#7: some EG4 LL-V2 units intermittently answer
with a CRC-valid function-03 response whose register data area is
entirely zero. The component published those zeroes as a real reading,
collapsing SoC, pack voltage and capacity for one poll cycle.
v1.1.0 rejects implausible blocks and no longer lets them refresh the
online tracker, so a unit stuck returning zeroes now goes offline
instead of reporting a flat-zero battery.
No YamBMS-side changes are required: neither EG4 package uses the
removed designed_capacity sensor, and both already use the
cell_average_voltage key.
Rewrote Auto CVL from template sensor lambdas to interval
lambdas, splitting each into a value sensor and a delta sensor.
Fixed a bug confirmed in production: Auto CVL's Float floor coincided
exactly with the Rebulk V. threshold, letting it trigger its own rebulk.
The floor is now capped relative to the live target instead of a fixed
chemistry constant, the Float/Stop integral term can no longer get stuck
once clamped, and PI state now resets when crossing the Bulk <-> Float/Stop
boundary.
This YAML file implements the Auto CCL Current Taper feature for the YamBMS project, defining various parameters and logic for charge current tapering during battery charging.
This adds `Rebulk Days` which specify the number of days since last full charge to enter `Bulk` again. It works like `Rebulk SoC` or `Rebulk V.` and can be disabled by setting it to 0 days.
- Disable when `Force Bulk` is active
- Disable when charging status is not `Bulk` or `Float`
- Add additional status messages to make clear what happens
- Adjusted light control logic to handle RGB settings and state changes more effectively.
- Introduced a new substitution `board_has_rgb` to indicate RGB functionality availability.
- Removed the deprecated `board_options_rgb_led_status.yaml` file.
- Enhanced CAN bus and RS485 configurations to include LED control based on device status.
- Updated T-Connect and YamBMS behaviour documentation
The `bms_ids` variable allows to provide an array of BMS IDs that are connected to this shunt.
If one or more BMS from this array are offline, the shunt is not used anymore (Combine = Disabled). This avoids returning a wrong SOC when not all batteries are online/available anymore.
If the BMS goes online again, the shunt is then used again.
This variable is optional. If not provided, the shunt work independently from the BMS online status.
Examples:
```
bms_ids: '{1}'
bms_ids: '{1, 2}'
bms_ids: '{4, 5, 6}'
```
* CCL, DCL and Auto Temp Current Control
* Added following:
- Update temperature based current derating, now uses calibrate_linear
- Revised CCL and DCL to correctly apply derating when multiple functions are enabled
- Added diagnostic sensor showing derating reason
* Changed referenced sensor for Auto DCP temperature derating
* Updated Auto Temp logic
* Add documentation, rename package