# Victron SmartShunt
|
|
|
|
[](https://www.gnu.org/licenses/gpl-3.0)
|
|
[](https://github.com/Sleeper85/esphome-yambms/releases/latest)
|
|

|
|

|
|

|
|
|
|
## UART : Schematic
|
|
|
|
> [!CAUTION]
|
|
> [Please read this page about setting up galvanic isolation of the `UART-TTL` connection.](Galvanic_isolation.md)
|
|
|
|
> [!TIP]
|
|
> If you are unsure about to pin order please measure the voltage between GND and VCC (5V). If you measure a positive voltage you know the position of VCC and GND!
|
|
|
|
```
|
|
┌─────────────────┐ ┌──────────┐ ┌───────────┐
|
|
│ 5V o│<----5V---V1>│ |<V2---3V3--->| |
|
|
│ Victron RX o│<---------AO<│ UART-TTL │<AI-------TX<| ESP32 |
|
|
│ SmartShunt TX o│>---------AI>│ ISOLATOR │>BO-------RX>| |
|
|
│ GND o│<----GND---->│ │<----GND---->| |
|
|
└─────────────────┘ └──────────┘ └───────────┘
|
|
|
|
# UART-TTL VE.Direct port (JST-PH 2.0mm pinch)
|
|
┌─── ─────── ────┐
|
|
│ │
|
|
│ O O O O │
|
|
│GND RX TX VCC │
|
|
└────────────────┘
|
|
│ │ │ └ 5V
|
|
│ │ └──── TX to TTL-isolator AI (input)
|
|
│ └──────── RX to TTL-isolator AO (output)
|
|
└──────────── GND to TTL-isolator GND
|
|
|
|
```
|
|
|
|
## Bluetooth : How to retrieve MAC address and encryption key
|
|
|
|
To connect to your Victron device with BLE component you must have two information :
|
|
|
|
- `mac_address` - Bluetooth mac address of device.
|
|
- `encryption_key` - AES encryption key.
|
|
|
|
Use [VictronConnect App v5.93](https://www.victronenergy.com/live/victronconnect:beta) (or later) released on 2023-08-25.
|
|
|
|
Connect to the SmartShunt via Bluetooth under the `Local` tab.
|
|
|
|

|
|

|
|

|
|

|
|
|
|
1. Open `Settings` of Device.
|
|
2. Open `Product Info` page.
|
|
3. Ensure `Instant readout via Bluetooth` is enabled.
|
|
4. Bottom of page press `SHOW` for Instant readout details Encryption data.
|
|
|
|
When connected to the device via VictronConnect App no Instant readout (Bluetooth advertising) data is generated.
|