Sleeper85 e4b8aacc0a Fixed 6h reboot on networks that filter the ESP32 outbound traffic
http_request runs on the loop task, which has a 4s budget before the
5s task WDT panics. A dropped connect() blocks for 4.5s (the ESPHome
default timeout) and a filtered port 53 blocks for a fixed 7s, which
timeout does not cover.

- timeout 3s and watchdog_timeout 60s cover the two blocking paths
- a failure counter stops the service after 3 network-level failures,
  instead of freezing the loop 14s every 6h forever
- the POST is now skipped when the GET failed

Reproduced and measured on OPNsense.
See Design_decisions.md.
2026-11-08 23:08:33 +01:00

8.2 KiB
Raw Blame History

Design decisions

Some parts of the codebase look more verbose or more redundant than they need to be. They are deliberate. This page records why, so that a well-intentioned cleanup doesn't reintroduce a bug that took a long time to find.

Do not refactor anything listed here without discussing it first, and read the rationale before touching the code.

Cut-Off / EOC logic

File: packages/yambms/yambms_core.yaml

The End Of Charge condition is deliberately compound. It has to distinguish a genuine EOC from a charge current that is merely capped by low solar production. Collapsing it into a single threshold or voltage comparison reintroduces false EOC on overcast days.

The combiner pipeline

Files: packages/bms/bms_combine.yaml, packages/shunt/shunt_combine.yaml, packages/yambms/yambms_core.yaml

Every BMS and Shunt package instance runs the same interval lambda, and they coordinate through a shared counter rather than through any central loop. Each instance only acts on the tick where var_to_combine_bms_number equals its own ${bms_id}, then increments the counter so the next instance can run. yambms_core.yaml (STEP 2) waits until every device has been processed, then resets the counters to 1 for the next round.

This is why bms_id must start at 1 and be contiguous. It is not a style rule and not only about the bitmask index: with a gap in the numbering, the counter stops at the missing id, never advances, and STEP 2 never fires. The whole pipeline deadlocks silently.

Include the BMS and Shunt packages in ascending id order. Out-of-order includes still converge, but spread one round over several intervals instead of completing in one.

can_be_combined is deliberately exhaustive

The condition in bms_combine.yaml checks every sensor the combiner will read. It is long on purpose: a single missing or NaN value entering the totals corrupts the aggregate that drives the inverter. Do not shorten it to a few representative checks.

Note that the checks are not uniform. Most use has_state(), but total_voltage, battery_capacity, max_charge_current and max_discharge_current use > 0 — a BMS reporting zero for those is treated as not ready rather than as a valid reading.

Combined once, combined continuously, uncombined

Three distinct scopes in the same lambda, and they are not interchangeable:

  • Once — total_installed_battery_capacity accumulates a single time per BMS, for the lifetime of the boot. It represents the installed capacity and deliberately does not shrink when a BMS drops offline.
  • Not continuously — the combined counter is incremented on the transition into the combined state, not on every tick.
  • Continuously — the totals, bitmasks and min/max values are recomputed every round.

bms_seen_online_bitmask is never cleared

It records that a BMS has been online at least once since boot. shunt_combine.yaml uses it to tell "this BMS is offline" apart from "this BMS was never there" — a shunt must not be uncombined because of a BMS the user never installed.

Cell numbers are offset per pack

The combiner reports cell number + (${bms_id} × 100), so cell 8 of BMS 1 is reported as 108 and cell 3 of BMS 2 as 203. This makes the pack immediately identifiable in the dashboard. It caps a pack at 99 cells, which is well beyond any realistic configuration.

A shunt uncombine turns the user switch off, and does not turn it back on

When a BMS mapped to a shunt goes offline, shunt_combine.yaml switches Combine enabled off and records which BMS caused it, so the diagnostic State entity can say so. Re-enabling is deliberately manual: coming back online does not automatically restore the combination, because the SoC reference has to be trusted before it is used again.

The {0} sentinel in bms_ids

shunt${shunt_id}_bms_map defaults to '{0}' because the vector needs a non-empty initialiser, and the loop skips id 0 (if (!bms_id) continue;). Do not "clean up" the zero — it is what makes an unmapped shunt valid.

CAN frame catalogue

File: packages/yambms/yambms_canbus.yaml

Several can_id values are reused with different payloads depending on the protocol:

CAN ID Frame Protocol
0x359 5 PYLON
0x359 24 Deye PCS
0x371 11 SEPLOS
0x371 28 Deye PCS

A frame's identity is its internal frame number, never its CAN ID. Do not merge two blocks because they share a CAN ID — that would break both protocols at once.

Byte order is not uniform either: 0x373 sends min cell voltage before max, 0x361 sends max before min. Both match their respective specifications. Do not "harmonise" them.

Frame sequencing

File: packages/yambms/yambms_canbus.yaml

Each protocol is defined as a sequence of frame numbers emitted on a fixed interval, so a full cycle lasts interval × sequence length — from a few hundred milliseconds to over a second depending on the protocol. Some inverters are sensitive to that cadence. Do not change the interval to make protocols "consistent" with each other.

When adding a frame to a sequence, remember that the sequence length is tracked alongside the array. Keep the two in sync, or the new frame will silently never be emitted.

The update service must never block the loop task

File: packages/yambms/yambms_service.yaml

http_request runs synchronously on the ESP32 loop task. ESPHome arms the IDF task watchdog at 5s with CONFIG_ESP_TASK_WDT_PANIC=y, and feeds it at most every 1 s, so any single blocking call has a 4s budget before the device panics and reboots.

Two paths exceed that budget on a network that filters outbound traffic. Both were reproduced on an OPNsense firewall and measured on hardware:

Path Blocking time Bounded by
Port 80 dropped silently 4.5s timeout, whose ESPHome default is 4.5s
Port 53 filtered (drop or reject) 7.0 s, fixed nothing — timeout does not cover DNS

The 7s figure is the lwIP resolver retry ladder (1 + 1 + 2 + 3s over DNS_MAX_RETRIES), and it is deterministic to a few milliseconds. A reject is not faster than a drop: lwIP's UDP API has no error callback, so the ICMP unreachable is counted and discarded, and the query still runs its full budget. Only an actual DNS answer — including NXDOMAIN from a local resolver — fails fast.

This is why three separate settings are needed, and none of them is redundant:

  • watchdog_timeout: 60s is the only thing that covers the DNS wait. It is never reached in normal operation, where a full request takes under 400 ms.
  • timeout: 3s brings the socket phase back under the 4s budget. It does not help the DNS case.
  • The failure counter (yambms${yambms_id}_var_service_failures) is what stops the loop from freezing for 7s every 6h, forever, on a device that will never reach the internet.

my_network.is_connected() is not a reachability test — it only proves the device holds an IP. It is kept as a cheap first filter, but the counter is the real guard. Do not remove it on the grounds that the connectivity check above it "already handles this".

The counter is incremented from on_error, which fires only when no connection could be made. An HTTP error status still fires on_response and resets the counter, which is correct: the network worked, so there is no freeze to protect against.

The POST is guarded by an if on the counter rather than nested inside the GET's on_response. Nesting would stack one blocking request inside another on a loop task whose stack is 8192 B by default — see LOOP_TASK_STACK.md. It also avoids a second 7s freeze on a filtered network, halving the worst case.

Reaching 3 failures disables the service until reboot, or until the user toggles the Update service switch off and on, which rearms the counter.

Empirical constants