* Fix Deye power update interval
* Keep batteries the report CCL/DCL 0A
A battery that reports a charge limit (CCL) or discharge limit (DCL) of 0 A now stays in the combine. Before, a full Deye at 0 A CCL, or an empty one at 0 A DCL, dropped out of capacity, SoC and the totals.
- Missing values are still caught: a CCL or DCL with no value yet still fails >= 0, because comparisons with NaN are always false.
- No effect on the limits: CCL and DCL are added up, so a battery at 0 A adds 0 A to the total.
- All BMS models are affected
https://github.com/Sleeper85/esphome-yambms/issues/335