# YamBMS - How to create your YamBMS YAML (Local Packages examples)
|
||
|
||
[](https://www.gnu.org/licenses/gpl-3.0)
|
||
[](https://github.com/Sleeper85/esphome-yambms/releases/latest)
|
||

|
||

|
||

|
||
|
||
> [!TIP]
|
||
> Not sure which YAML to choose ? ... `YamBMS_Remote_Packages_example.yaml` is a good basis for creating your custom YAML.
|
||
> Examples of BMS imports can be found in the [configuration_examples](configuration_examples/) folder.
|
||
> You can mix different BMS models, the only condition is that they are numbered in order starting from `1`.
|
||
|
||
> [!IMPORTANT]
|
||
> BMS monitoring with `Bluetooth` as well as the `Web server` are RAM-intensive components.
|
||
> Please note that enabling these components will take up a lot of memory and may decrease the stability of your ESP32.
|
||
|
||
## WiFi & Ethernet
|
||
|
||
> [!IMPORTANT]
|
||
> By default, if the ESP32 is disconnected from the WiFi network it will reboot `every 15 minutes` to try to resolve the problem.
|
||
> The `wifi` or `ethernet` components are found in the [YAML corresponding to the board](../../packages/board/).
|
||
|
||
Configuring a fixed IP address can be done in the main YAML like this:
|
||
|
||
### WiFi
|
||
|
||
> [!IMPORTANT]
|
||
> Don't forget to configure your WiFi credentials in the `secrets.yaml` file.
|
||
|
||
```YAML
|
||
wifi:
|
||
manual_ip:
|
||
static_ip: 192.168.0.85
|
||
gateway: 192.168.0.1
|
||
subnet: 255.255.255.0
|
||
dns1: 8.8.8.8
|
||
dns2: 8.8.4.4
|
||
```
|
||
|
||
### Ethernet
|
||
|
||
```YAML
|
||
ethernet:
|
||
manual_ip:
|
||
static_ip: 192.168.0.85
|
||
gateway: 192.168.0.1
|
||
subnet: 255.255.255.0
|
||
dns1: 8.8.8.8
|
||
dns2: 8.8.4.4
|
||
```
|
||
|
||
## Home Assistant API
|
||
|
||
> [!IMPORTANT]
|
||
> If your ESP32 is not connected with Home Assistant it will reboot every 15 minutes.
|
||
> This is the normal behavior of ESPHome, this is not a bug to be resolved but a mechanism put in place by the ESPHome team to correct a possible problem with the API connection.
|
||
|
||
The **"api:"** section is therefore configured by default not to reboot every 15 minutes if `Home Assistant` is not connected.
|
||
|
||
```YAML
|
||
api:
|
||
reboot_timeout: 0s
|
||
```
|
||
|
||
## Web Server
|
||
|
||
> [!IMPORTANT]
|
||
> Please note that enabling this component will take up a lot of memory and may decrease stability and be the cause of reboot depending on the capabilities of the board used.
|
||
|
||
If you don't use `Home Assistant`, you can activate the `Web Server` and have access to YamBMS information and also interact with the application.
|
||
|
||
[ESPHome Web Server Component](https://esphome.io/components/web_server.html)
|
||
|
||
## Importing YamBMS packages
|
||
|
||
Package imports are done below this line:
|
||
|
||
```YAML
|
||
packages:
|
||
```
|
||
|
||
## Board
|
||
|
||
First you need to import the package that corresponds to the `board` you are going to use.
|
||
|
||
There are other `board.yaml` not mentioned here, see in the [board](../../packages/board/) folder.
|
||
|
||
So just one of the packages below :
|
||
|
||
### ESP32 Generic
|
||
|
||
```YAML
|
||
device_board: !include packages/board/board_ESP32_Generic.yaml
|
||
```
|
||
|
||
### ESP32 DevKit-V1
|
||
|
||
```YAML
|
||
device_board: !include packages/board/board_ESP32_DevKit-V1.yaml
|
||
```
|
||
|
||
### ESP32-S3 DevKitC-1
|
||
|
||
```YAML
|
||
device_board: !include packages/board/board_ESP32-S3_DevKitC-1.yaml
|
||
```
|
||
|
||
### Atom S3 Lite
|
||
|
||
```YAML
|
||
device_board: !include packages/board/board_ESP32-S3_AtomS3-Lite.yaml
|
||
```
|
||
|
||
### Atom S3 / S3R (display)
|
||
|
||
In this case you need to specify the `yambms` and `canbus` IDs to display the information on the screen.
|
||
|
||
```YAML
|
||
device_board: !include
|
||
file: packages/board/board_ESP32-S3_AtomS3.yaml
|
||
vars:
|
||
display_auto_next_page_interval: '5s'
|
||
```
|
||
|
||
```YAML
|
||
device_board: !include
|
||
file: packages/board/board_ESP32-S3_AtomS3R.yaml
|
||
vars:
|
||
display_auto_next_page_interval: '5s'
|
||
```
|
||
|
||
### ESP32-C3 DevKitM-1
|
||
|
||
```YAML
|
||
device_board: !include packages/board_ESP32-C3_DevKitM-1.yaml
|
||
```
|
||
|
||
### ESP32-C3 ETH01-EVO
|
||
|
||
This board has an `Ethernet` port and can be powered from `POE` (optional).
|
||
|
||
```YAML
|
||
device_board: !include packages/board/board_ESP32-C3_ETH01-EVO.yaml
|
||
```
|
||
|
||
### ESP32 LilyGo T-CAN485
|
||
|
||
```YAML
|
||
device_board: !include packages/board/board_ESP32_LilyGo-T-CAN485.yaml
|
||
```
|
||
|
||
### ESP32-S3 LilyGo T-Connect
|
||
|
||
```YAML
|
||
device_board: !include packages/board/board_ESP32-S3_LilyGo-T-Connect.yaml
|
||
```
|
||
|
||
## YamBMS single-node example
|
||
|
||
```YAML
|
||
shunt1: !include
|
||
file: packages/shunt/shunt_combine_Victron_SmartShunt_UART.yaml
|
||
vars:
|
||
shunt_id: '1' # must be a number
|
||
shunt_name: 'Shunt 1'
|
||
# other settings
|
||
# ...
|
||
|
||
bms1: !include
|
||
file: packages/bms/bms_combine_JK_UART_4G-GPS_full.yaml
|
||
vars:
|
||
bms_id: '1' # must be a number
|
||
bms_name: 'BMS 1'
|
||
# other settings
|
||
# ...
|
||
|
||
bms2: !include
|
||
file: packages/bms/bms_combine_JBD_UART_full.yaml
|
||
vars:
|
||
bms_id: '2' # must be a number
|
||
bms_name: 'BMS 2'
|
||
# other settings
|
||
# ...
|
||
```
|
||
|
||
## YamBMS multi-node RS485 modbus example
|
||
|
||
> [!IMPORTANT]
|
||
> The BMS/Shunt IDs of the `modbus client` must match exactly with the BMS/Shunt IDs of the `modbus server` as in the example below.
|
||
|
||
### YamBMS modbus client `node1`
|
||
|
||
```YAML
|
||
modbus: !include
|
||
file: packages/base/device_modbus.yaml
|
||
vars:
|
||
modbus_role: 'client' # client / server
|
||
modbus_uart_id: 'uart_esp_1' # RS485 board
|
||
|
||
shunt1: !include
|
||
file: packages/shunt/shunt_combine_modbus_client.yaml # a Shunt connected to a node of the RS485 bus
|
||
vars:
|
||
shunt_id: '1' # must be a number, also represents the modbus server number (200 + shunt_id) !
|
||
shunt_name: 'Shunt 1'
|
||
|
||
bms1: !include
|
||
file: packages/bms/bms_combine_modbus_client.yaml # a BMS connected to a node of the RS485 bus
|
||
vars:
|
||
bms_id: '1' # must be a number, also represents the modbus server number !
|
||
bms_name: 'BMS 1'
|
||
|
||
bms2: !include
|
||
file: packages/bms/bms_combine_modbus_client.yaml # a BMS connected to a node of the RS485 bus
|
||
vars:
|
||
bms_id: '2' # must be a number, also represents the modbus server number !
|
||
bms_name: 'BMS 2'
|
||
|
||
bms3: !include
|
||
file: packages/bms/bms_combine_modbus_client.yaml # a BMS connected to a node of the RS485 bus
|
||
vars:
|
||
bms_id: '3' # must be a number, also represents the modbus server number !
|
||
bms_name: 'BMS 3'
|
||
```
|
||
|
||
### ESP32 modbus server `node2`
|
||
|
||
```YAML
|
||
modbus: !include
|
||
file: packages/base/device_modbus.yaml
|
||
vars:
|
||
modbus_role: 'server' # client / server
|
||
modbus_uart_id: 'uart_esp_1' # RS485 board
|
||
|
||
shunt1: !include
|
||
file: packages/shunt/shunt_modbus_Victron_SmartShunt_UART.yaml
|
||
vars:
|
||
shunt_id: '1' # must be a number, also represents the modbus server number (200 + shunt_id) !
|
||
shunt_name: 'Shunt 1'
|
||
# other settings
|
||
# ...
|
||
|
||
bms1: !include
|
||
file: packages/bms/bms_modbus_JK_UART_4G-GPS_full.yaml
|
||
vars:
|
||
bms_id: '1' # must be a number, also represents the modbus server number !
|
||
bms_name: 'BMS 1'
|
||
# other settings
|
||
# ...
|
||
```
|
||
|
||
### ESP32 modbus server `node3`
|
||
|
||
```YAML
|
||
modbus: !include
|
||
file: packages/base/device_modbus.yaml
|
||
vars:
|
||
modbus_role: 'server' # client / server
|
||
modbus_uart_id: 'uart_esp_1' # RS485 board
|
||
|
||
bms2: !include
|
||
file: packages/bms/bms_modbus_JK_BLE_standard.yaml
|
||
vars:
|
||
bms_id: '2' # must be a number, also represents the modbus server number !
|
||
bms_name: 'BMS 2'
|
||
# other settings
|
||
# ...
|
||
|
||
bms3: !include
|
||
file: packages/bms/bms_modbus_JK_BLE_standard.yaml
|
||
vars:
|
||
bms_id: '3' # must be a number, also represents the modbus server number !
|
||
bms_name: 'BMS 3'
|
||
# other settings
|
||
# ...
|
||
```
|
||
|
||
## BMS
|
||
|
||
> [!IMPORTANT]
|
||
> You must number your `BMS` in order starting with the number `1`.
|
||
|
||
> [!TIP]
|
||
> YAML files whose name starts with `bms_combine` are to be used on the main `YamBMS` node connected to your inverter, those whose name starts with `bms_modbus` are to be used on the other nodes connected to the `RS485` bus.
|
||
|
||
The example YAMLs are just examples, you can mix different BMS models without problems.
|
||
|
||
There are other `bms.yaml` not mentioned here, see in the [bms](../../packages/bms/) folder.
|
||
|
||
The `full` / `standard` versions contain all available sensors while the `minimal` version contains the basic sensors without the voltages of each cell and other superfluous sensors.
|
||
|
||
### [JK-BMS (BLE)](https://github.com/syssi/esphome-jk-bms)
|
||
|
||
> [!IMPORTANT]
|
||
> The BLE software stack on the ESP32 consumes a significant amount of RAM on the device.
|
||
> Crashes are likely to occur if you include too many additional components in your device’s configuration.
|
||
> I recommend using `UART` or `RS485` if possible.
|
||
|
||
```YAML
|
||
bms1: !include
|
||
file: packages/bms/bms_combine_JK_BLE_standard.yaml # bms_modbus_JK_BLE_standard.yaml
|
||
vars:
|
||
bms_id: '1' # must be a number
|
||
bms_name: 'BMS 1'
|
||
bms_ble_protocol_version: 'JK02_32S' # JK02_24S < hardware version 11.0 >= JK02_32S
|
||
bms_ble_mac_address: 'C8:47:8C:10:7E:AA' # Your MAC address
|
||
# Maximum cell charging cycles is used to calculate the battey SoH.
|
||
# MB31=8000.0, LF280K v3=8000.0, LF280K v2=6000.0, LF280=3000.0 (decimal is required)
|
||
bms_cell_max_cycles: '6000.0'
|
||
```
|
||
|
||
### [JK-BMS (UART 4G-GPS)](https://github.com/syssi/esphome-jk-bms)
|
||
|
||
[How to make the UART connection with the ESP32.](BMS_JK-B_UART_solution.md)
|
||
|
||
```YAML
|
||
bms1: !include
|
||
file: packages/bms/bms_combine_JK_UART_4G-GPS_full.yaml # bms_modbus_JK_UART_4G-GPS_full.yaml
|
||
vars:
|
||
bms_id: '1' # must be a number
|
||
bms_name: 'BMS 1'
|
||
bms_uart_id: 'uart_esp_1'
|
||
# Maximum cell charging cycles is used to calculate the battey SoH.
|
||
# MB31=8000.0, LF280K v3=8000.0, LF280K v2=6000.0, LF280=3000.0 (decimal is required)
|
||
bms_cell_max_cycles: '6000.0'
|
||
```
|
||
|
||
### [JK-BMS (RS485 DISPLAY)](https://github.com/syssi/esphome-jk-bms)
|
||
|
||
> [!CAUTION]
|
||
> The `jk_bms_display` component does not provide all the information needed for an optimal operation of `YamBMS`.
|
||
> The missing information has been added in the code by fixed values.
|
||
> e.g. it's not possible to know if the BMS is `online` or if the BMS is `equalizing` the cells.
|
||
|
||
[How to make the RS485 connection with the ESP32.](BMS_JK-B_RS485_DISPLAY_solution.md)
|
||
|
||
```YAML
|
||
bms1: !include
|
||
file: packages/bms/bms_combine_JK_RS485_DISPLAY_full.yaml
|
||
vars:
|
||
bms_id: '1' # must be a number
|
||
bms_name: 'BMS 1'
|
||
bms_uart_id: 'uart_esp_1'
|
||
# Required settings cannot be retrieved from BMS
|
||
# These values must match your BMS settings
|
||
# LFP values example
|
||
bms_battery_capacity: '280' # Ah
|
||
bms_max_charge_current: '100' # A. Used to calculate maximum charge current
|
||
bms_max_discharge_current: '100' # A. Used to calculate maximum discharge current
|
||
bms_cell_ovp: '3.650' # V. Used by 'Auto CCL' functions
|
||
bms_cell_uvp: '2.800' # V. Used by 'Auto DCL' functions and to calculate maximum discharge voltage
|
||
# Maximum cell charging cycles is used to calculate the battey SoH.
|
||
# MB31=8000.0, LF280K v3=8000.0, LF280K v2=6000.0, LF280=3000.0 (decimal is required)
|
||
bms_cell_max_cycles: '6000.0'
|
||
```
|
||
|
||
### [JK-BMS (RS485 Modbus)](https://github.com/txubelaxu/esphome-jk-bms/)
|
||
|
||
> [!TIP]
|
||
> Compatible with JK-PB, JK-B HW. >= 11A
|
||
|
||
A single `RS485 bus` allows you to monitor up to `16` BMS.
|
||
|
||
[How to make the RS485 connection with the ESP32.](BMS_JK-PB_RS485_solution.md)
|
||
|
||
#### JK sniffer
|
||
|
||
> [!IMPORTANT]
|
||
> You need to import only one `sniffer` package of your choice.
|
||
> Depending on which `RS485` board you have, you should use the version of the `sniffer` with or without `talk_pin`.
|
||
|
||
The sniffer represents the ESP node connected to the JK-PB RS485 bus
|
||
If address `0x00` is not detected on the RS485 bus, the sniffer will act directly as a master BMS (mode 2, max 15 BMS).
|
||
|
||
Sniffer without `talk_pin` :
|
||
|
||
```YAML
|
||
sniffer1: !include
|
||
file: packages/bms/bms_combine_JK_RS485_Modbus_sniffer.yaml
|
||
vars:
|
||
sniffer_id: 'sniffer1'
|
||
sniffer_protocol: 'JK02_32S'
|
||
sniffer_uart_id: 'uart_esp_1'
|
||
```
|
||
|
||
If your `RS485` board requires a `talk_pin` you must specify which `GPIO` will be used :
|
||
|
||
```YAML
|
||
sniffer1: !include
|
||
file: packages/bms/bms_combine_JK_RS485_Modbus_sniffer_talk_pin.yaml
|
||
vars:
|
||
sniffer_id: 'sniffer1'
|
||
sniffer_protocol: 'JK02_32S'
|
||
sniffer_uart_id: 'uart_esp_1'
|
||
sniffer_talk_pin: 8 # ESP32: 4, ESP32-S3: 8, ESP32-C3: 10
|
||
```
|
||
|
||
#### JK-BMS (JK-PB, JK-B HW. >= 11A)
|
||
|
||
```YAML
|
||
# Mode2 : configure the DIP switches of your BMS from 0x01 to 0x0F (don't use the 0x00 address, maximum 15 BMS)
|
||
bms1: !include
|
||
file: packages/bms/bms_combine_JK_RS485_Modbus_bms_full.yaml
|
||
vars:
|
||
# Sniffer ID
|
||
sniffer_id: 'sniffer1'
|
||
# BMS vars
|
||
bms_id: '1' # must be a number
|
||
bms_name: 'JK-BMS 1'
|
||
bms_address: '0x01' # BMS 1 DIP switch
|
||
```
|
||
|
||
### [JBD (UART)](https://github.com/syssi/esphome-jbd-bms)
|
||
|
||
```YAML
|
||
bms1: !include
|
||
file: packages/bms/bms_combine_JBD_UART_full.yaml # bms_modbus_JBD_UART_full.yaml
|
||
vars:
|
||
bms_id: '1' # must be a number
|
||
bms_name: 'BMS 1'
|
||
bms_uart_id: 'uart_esp_1'
|
||
bms_rx_timeout: '150ms'
|
||
# Required settings cannot be retrieved from BMS
|
||
# These values must match your BMS settings
|
||
# LFP values example
|
||
bms_max_charge_current: '100' # A. Used to calculate maximum charge current
|
||
bms_max_discharge_current: '100' # A. Used to calculate maximum discharge current
|
||
bms_cell_ovp: '3.650' # V. Used by 'Auto CCL' functions
|
||
bms_cell_uvp: '2.800' # V. Used by 'Auto DCL' functions and to calculate maximum discharge voltage
|
||
bms_balance_trigger_voltage: '0.010' # V. Used by 'Auto CVL' functions
|
||
# Maximum cell charging cycles is used to calculate the battey SoH.
|
||
# MB31=8000.0, LF280K v3=8000.0, LF280K v2=6000.0, LF280=3000.0 (decimal is required)
|
||
bms_cell_max_cycles: '6000.0'
|
||
```
|
||
|
||
### [JBD (BLE)](https://github.com/syssi/esphome-jbd-bms)
|
||
|
||
```YAML
|
||
bms1: !include
|
||
file: packages/bms/bms_combine_JBD_BLE_full.yaml # bms_modbus_JBD_UART_full.yaml
|
||
vars:
|
||
bms_id: '1' # must be a number
|
||
bms_name: 'BMS 1'
|
||
bms_ble_mac_address: 'C8:47:8C:10:7E:AA' # Your MAC address
|
||
# Required settings cannot be retrieved from BMS
|
||
# These values must match your BMS settings
|
||
# LFP values example
|
||
bms_max_charge_current: '100' # A. Used to calculate maximum charge current
|
||
bms_max_discharge_current: '100' # A. Used to calculate maximum discharge current
|
||
bms_cell_ovp: '3.650' # V. Used by 'Auto CCL' functions
|
||
bms_cell_uvp: '2.800' # V. Used by 'Auto DCL' functions and to calculate maximum discharge voltage
|
||
bms_balance_trigger_voltage: '0.010' # V. Used by 'Auto CVL' functions
|
||
# Maximum cell charging cycles is used to calculate the battey SoH.
|
||
# MB31=8000.0, LF280K v3=8000.0, LF280K v2=6000.0, LF280=3000.0 (decimal is required)
|
||
bms_cell_max_cycles: '6000.0'
|
||
```
|
||
|
||
### [Seplos V1/V2 (RS485)](https://github.com/syssi/esphome-seplos-bms)
|
||
|
||
A single `RS485 bus` allows you to monitor up to `16` BMS.
|
||
|
||
> [!CAUTION]
|
||
> The `seplos_bms` component does not provide all the information needed for an optimal operation of `YamBMS`.
|
||
> The missing information has been added in the code by fixed values.
|
||
> e.g. it's not possible to know if the BMS **blocks** the `charge` or the `discharge` or if the BMS is `equalizing` the cells.
|
||
> The `online` status has not been tested.
|
||
|
||
> [!IMPORTANT]
|
||
> You need to import only one `seplos_modbus`.
|
||
|
||
#### Seplos modbus
|
||
|
||
```YAML
|
||
seplos_modbus1: !include
|
||
file: packages/bms/bms_combine_SEPLOS_V1_V2_RS485_modbus.yaml
|
||
vars:
|
||
seplos_modbus_id: 'seplos_modbus1'
|
||
seplos_modbus_uart_id: 'uart_esp_1'
|
||
seplos_modbus_baud_rate: '9600' # 9600 / 19200 ; please set the baudrate of your Seplos BMS model here
|
||
seplos_modbus_rx_timeout: '150ms'
|
||
```
|
||
|
||
#### Seplos V1/V2 BMS
|
||
|
||
```YAML
|
||
bms1: !include
|
||
file: packages/bms/bms_combine_SEPLOS_V1_V2_RS485_bms_full.yaml
|
||
vars:
|
||
# Seplos modbus ID
|
||
seplos_modbus_id: 'seplos_modbus1'
|
||
# BMS vars
|
||
bms_id: '1' # must be a number
|
||
bms_name: 'BMS 1'
|
||
bms_address: '0x01' # BMS 1 DIP switch
|
||
bms_protocol_version: '0x20' # Known protocol versions: 0x20 (Seplos), 0x26 (Boqiang)
|
||
# Required settings cannot be retrieved from BMS
|
||
# These values must match your BMS settings
|
||
# LFP values example
|
||
bms_max_charge_current: '100' # A. Used to calculate maximum charge current
|
||
bms_max_discharge_current: '100' # A. Used to calculate maximum discharge current
|
||
bms_cell_ovp: '3.650' # V. Used by 'Auto CCL' functions
|
||
bms_cell_uvp: '2.800' # V. Used by 'Auto DCL' functions and to calculate maximum discharge voltage
|
||
bms_balance_trigger_voltage: '0.010' # V. Used by 'Auto CVL' functions
|
||
```
|
||
|
||
## Shunt
|
||
|
||
> [!IMPORTANT]
|
||
> You must number your `Shunt` in order starting with the number `1`.
|
||
|
||
> [!TIP]
|
||
> YAML files whose name starts with `shunt_combine` are to be used on the main `YamBMS` node connected to your inverter, those whose name starts with `shunt_modbus` are to be used on the other nodes connected to the `RS485` bus.
|
||
|
||
As soon as you import a `Shunt` and it can be combined ([see condition](YamBMS_behavior.md#shunt)) the values `Voltage`, `Current`, `Power` and `SoC` of the shunt(s) will take precedence over the BMS values.
|
||
|
||
|
||
### [Victron Smartshunt (UART)](https://github.com/KinDR007/VictronMPPT-ESPHOME)
|
||
|
||
[How to make the UART connection with the ESP32.](Shunt_Victron_SmartShunt_HowTo.md)
|
||
|
||
```YAML
|
||
shunt1: !include
|
||
file: packages/shunt/shunt_combine_Victron_SmartShunt_UART.yaml # shunt_modbus_Victron_SmartShunt_UART.yaml
|
||
vars:
|
||
shunt_id: '1' # must be a number
|
||
shunt_name: 'Shunt 1'
|
||
shunt_uart_id: 'uart_esp_1'
|
||
```
|
||
|
||
### [Victron Smartshunt (BLE)](https://github.com/Fabian-Schmidt/esphome-victron_ble)
|
||
|
||
> [!IMPORTANT]
|
||
> The BLE software stack on the ESP32 consumes a significant amount of RAM on the device.
|
||
> Crashes are likely to occur if you include too many additional components in your device’s configuration.
|
||
> I recommend using `UART` or `RS485` if possible.
|
||
|
||
[How to make the BLE connection with the ESP32.](Shunt_Victron_SmartShunt_HowTo.md)
|
||
|
||
```YAML
|
||
shunt1: !include
|
||
file: packages/shunt/shunt_combine_Victron_SmartShunt_BLE.yaml # shunt_modbus_Victron_SmartShunt_BLE.yaml
|
||
vars:
|
||
shunt_id: '1' # must be a number
|
||
shunt_name: 'Shunt 1'
|
||
shunt_mac_address: '60:A4:23:91:8F:55' # Your MAC address
|
||
shunt_encryption_key: '0df4d0395b7d1a876c0c33ecb9e70dcd' # Your encryption key
|
||
```
|
||
|
||
### [Junctek KH-F (UART/RS485)](https://github.com/Sleeper85/esphome-junctek_khf)
|
||
|
||
```YAML
|
||
shunt1: !include
|
||
file: packages/shunt/shunt_combine_Junctek_KHF_UART.yaml # shunt_modbus_Junctek_KHF_UART.yaml
|
||
vars:
|
||
shunt_id: '1' # must be a number
|
||
shunt_name: 'Shunt 1'
|
||
shunt_uart_id: 'uart_esp_1'
|
||
```
|
||
|
||
## YamBMS
|
||
|
||
> [!TIP]
|
||
> This package is only used with the `YamBMS` main node.
|
||
|
||
> [!CAUTION]
|
||
> By default, `YamBMS` is configured with the values for a 16S LFP battery !
|
||
|
||
Take the time to configure `YamBMS` correctly according to your battery chemistry type `LFP/Li-ion/LTO` and `cell count`. Charging voltages can be changed in the app.
|
||
|
||
```YAML
|
||
yambms1: !include
|
||
file: packages/yambms/yambms.yaml
|
||
vars:
|
||
# Please read the cut-off charging logic README to understand how the YamBMS works
|
||
yambms_update_interval: '1s'
|
||
# Input numbers can be displayed as a slider or an input box, options are 'slider' or 'box'.
|
||
yambms_input_number_mode: 'slider'
|
||
# Please check and fill in the options below correctly according to your battery chemistry and number of cells in series.
|
||
# These parameters are important and used for charging logic.
|
||
# Battery Chemistry
|
||
yambms_battery_chemistry: '1' # 1-LFP | 2-Li-ion | 3-LTO
|
||
# Number of cells in series
|
||
yambms_cell_count: '16'
|
||
# Bulk / Absorption Voltage : corresponds to the Bulk voltage that will be used to charge the battery. (LFP : 55.2V = 3.45V/Cell for 16S battery)
|
||
yambms_bulk_v: '55.2'
|
||
# Float Voltage : corresponds to the voltage at which the battery would be maintained at the end of charge. (LFP : 53.6V = 3.35V/Cell for 16S battery)
|
||
yambms_float_v: '53.6'
|
||
# Rebulk voltage, voltage from which a new Bulk charge can start. (LFP : 52.8V = 3.3V/Cell for 16S battery)
|
||
yambms_rebulk_v: '52.8'
|
||
# Maximum time in minutes that the cut-off step can last before charging is complete
|
||
# If your cells are properly balanced this step ends at the fastest after the `cut-off timer`
|
||
# This timer can be deactivated with a switch
|
||
yambms_eoc_timer: '30'
|
||
# Time in seconds during which the end of charge conditions must be respected (cut-off + cells not equalizing)
|
||
yambms_cutoff_timer: '60'
|
||
```
|
||
|
||
## CAN bus
|
||
|
||
> [!TIP]
|
||
> This package is only used with the `YamBMS` main node.
|
||
> It's possible to use this package multiple times in order to send information on two different CAN bus.
|
||
|
||
The CAN bus connected to your inverter via the CAN transceiver `canbus_node1`.
|
||
|
||
You can keep the default configuration.
|
||
|
||
```YAML
|
||
canbus1: !include
|
||
file: packages/yambms/yambms_canbus.yaml
|
||
vars:
|
||
# CANBUS vars
|
||
canbus_id: 'canbus1'
|
||
canbus_name: 'CANBUS 1'
|
||
canbus_node_id: 'canbus_inverter_1'
|
||
canbus_light_id: 'esp_light'
|
||
# The CANBUS link will be considered down if no response from the inverter (ID 0x305) for 5s
|
||
# The Deye inverter sends the ACK (can_id 0x305) only when it receives the can_id 0x356
|
||
canbus_link_timer: '5s'
|
||
```
|
||
|
||
## Debug
|
||
|
||
The `debug` package will add useful information to refer to if problems occur.
|
||
|
||
### ESP32 and AtomS3
|
||
|
||
```YAML
|
||
device_debug: !include
|
||
file: packages/base/device_debug_ESP32.yaml
|
||
vars:
|
||
debug_name: 'Debug'
|
||
debug_update_interval: '5s'
|
||
```
|
||
|
||
### ESP32 with PSRAM memory like ESP32-S3 / AtomS3R
|
||
|
||
```YAML
|
||
device_debug: !include
|
||
file: packages/base/device_debug_ESP32-S3.yaml
|
||
vars:
|
||
debug_name: 'Debug'
|
||
debug_update_interval: '5s'
|
||
# Size of your PSRAM in bits
|
||
# 8Mb='8388608' | 6Mb='6291456' | 4Mb='4194304' | 2Mb='2097152' | NoPSRAM='0'
|
||
debug_psram_size: '8388608'
|
||
```
|