YamBMS functions

Badge License: GPLv3 Badge Version GitHub stars GitHub forks GitHub watchers

CAN protocol

Important

You need to check if your inverter model is on the list of supported inverters. In any case it must support one of the following CAN bus protocols.

Image

Choose the CAN protocol that will be sent to your inverter and don't forget to configure your inverter for the protocol you choose.

The table below helps you choose the best protocol depending on your inverter brand. Other configurations are possible, don't hesitate to communicate what works well for you.

Inverter Battery mode CAN protocol
Deye Lithium 00 PYLON 1.2
GoodWe LX U5.4-L PYLON +
Sofar Automatic PYLON 1.2
Growatt CAN L52 PYLON 1.2
Solis AoBo SMA
LuxPower Lithium 6 LuxPower
EG4 Lithium 6 LuxPower
Victron ESS Victron
SMA - SMA

Charging settings

Image

The Charging status represents the current charging phase, see the Charging logic.

The Charging instruction is defined based on the Charging status and allows the correct Requested Charge Values ​​to be sent.

The Float charge enabled switch allows the battery to be kept fully charged at the end of the Bulk charge. The voltage used will be that of the Float voltage slider.

The EOC timer enabled switch ensures that the Cut-Off phase lasts maximum 30 min (default value) even if your cells are still being equalized. If your cells are equalized, the Cut-Off phase will end at the earliest after 60s (default value). This prevents the risk of staying in the Cut-Off phase for many hours if you have several batteries and they are poorly equalized.

The Bulk voltage slider allows you to set the voltage used during the Bulk, Balancing and Cut-Off phases.

The Float voltage slider allows you to set the voltage used after charging is complete if the Float charge enabled switch is enabled.

The Inverter Offset V. slider allows you to correct the inverter charge voltage, either because it does not respect the requested value or because your inverter is far from your batteries and there is a voltage drop. This allows you to reach the target Bulk or Float charge voltage by adding an offset.

Max current (%)

Image

The allowed charge or discharge current is automatically calculated based on the OCP values ​​of your BMS. The OCP currents of the combined BMS (not in alarm) are added together and the requested current is a percentage 0~90% of this value.

ReBulk

Image

There are two parameters to start a new Bulk phase. You can set a Rebulk SoC or a Rebulk V. value, only one of these conditions must be met.

If needed you can also force a Bulk charge with the Force Bulk (top bal) switch. The switch will automatically deactivate when your cells enter the Balancing phase.

Request Force Charge

Image

This function allows you to force a charge from GRID :

  • when SoC <= Start SoC the forced charge start
  • when SoC >= Stop SoC the forced charge stop

Works only with PYLON, LuxPower and Victron protocols.

Auto functions

Thanks to @MrPabloUK for developing these features.

A reference spreadsheet has been created that shows how the Auto functions works.

Image

Auto CVL

When enabled, the Automatic Charge Voltage Limit feature will automatically reduce the Requested Charge Voltage (CVL) sent to the inverter when a cell starts to exceed the bulk target. That way, the runner cell should be maintained at or near bulk (for example, 3.45v) and the balancer can start to bring up the lagging cells. Controlling the CVL is the preferred option according to Victron and others, but it depends on how well your inverter behaves. My Solis inverter is not great at CVL control, so it doesn't work well for me.

You can compare Auto CVL to cruise control in a car.

Auto CCL & DCL

Regarding the new Auto Charge/Discharge Current Limit, this features has been introduced to hopefully prevent OVP and UVP alarms.

When enabled, the Automatic Charge Current Limit feature will automatically reduce the Requested Charge Current (CCL) sent to the inverter when a cell starts to exceed the bulk target. This should prevent the runner cell from exceeding the max voltage cutoff, but doesn't maintain it at bulk voltage - instead it should keep it just below max cell voltage.

You can compare Auto CCL to a max speed limiter in a car.

Auto DCL works the same way when a cell approaching UVPR.

Current control should work with any inverter that uses CAN control.

Requested Values

Image

These 4 sensors allow you to see what is being requested of your inverter.

In the example below, we are in the Float phase at a voltage of 53.6V and an Inverter Offset V. of 0.1V. The Requested Charge Voltage is therefore 53.7V.

The Requested Discharge Voltage is the UVPR value of your BMS multiplied by the number of cells, in this example (3V * 16).

The Requested Charge/Discharge Current is the OCP value of your BMS multiplied by the Max current percentage, in this example (150A * 80%).

Inverter Heartbeat Monitoring

Image

This feature allows you to monitor the heartbeat of your inverter (time between two ACK 0x305). This is useful for troubleshooting purposes and should not remain enabled continuously.

This heartbeat must be regular and depends on the selected CAN protocol and the behavior of the inverter. If the heartbeat is not regular this can show a problem on the inverter side or an overloaded ESP32.

The Deye inverter sends an ACK 0x305 in response to the reception of a CAN frame 0x356. Knowing that CAN frames are sent every 100ms and that the CAN protocol PYLON 1.2 has 6 CAN frames, the heartbeat of the Deye inverter is 600ms.

Important

Every 2h Deye takes more than 3s to respond and more than 5s at midnight. This is what the CANBUS Status looks like when the canbus_link_timer is set to 3s.

Image

Diagnostic

Useful information for troubleshooting.

Image

YamBMS version

This function lets you know if a new version of YamBMS is available, the check is done every 6 hours.

Image