# Design decisions
Some parts of the codebase look more verbose or more redundant than they need to be. They are
deliberate. This page records why, so that a well-intentioned cleanup doesn't reintroduce a bug
that took a long time to find.
**Do not refactor anything listed here without discussing it first**, and read the rationale
before touching the code.
## Cut-Off / EOC logic
**File:** `packages/yambms/yambms_core.yaml`
The End Of Charge condition is deliberately compound. It has to distinguish a genuine EOC from a
charge current that is merely capped by low solar production. Collapsing it into a single
threshold or voltage comparison reintroduces false EOC on overcast days.
<!-- TODO maintainer: list the exact elements that must not be merged (timer, latched state,
compound conditions) — see v1.7.1. -->
## The combiner pipeline
**Files:** `packages/bms/bms_combine.yaml`, `packages/shunt/shunt_combine.yaml`,
`packages/yambms/yambms_core.yaml`
Every BMS and Shunt package instance runs the *same* interval lambda, and they coordinate through
a shared counter rather than through any central loop. Each instance only acts on the tick where
`var_to_combine_bms_number` equals its own `${bms_id}`, then increments the counter so the next
instance can run. `yambms_core.yaml` (STEP 2) waits until every device has been processed, then
resets the counters to `1` for the next round.
This is why `bms_id` **must start at 1 and be contiguous**. It is not a style rule and not only
about the bitmask index: with a gap in the numbering, the counter stops at the missing id, never
advances, and STEP 2 never fires. The whole pipeline deadlocks silently.
Include the BMS and Shunt packages in ascending id order. Out-of-order includes still converge,
but spread one round over several intervals instead of completing in one.
### `can_be_combined` is deliberately exhaustive
The condition in `bms_combine.yaml` checks every sensor the combiner will read. It is long on
purpose: a single missing or `NaN` value entering the totals corrupts the aggregate that drives
the inverter. Do not shorten it to a few representative checks.
Note that the checks are not uniform. Most use `has_state()`, but `total_voltage`,
`battery_capacity`, `max_charge_current` and `max_discharge_current` use `> 0` — a BMS reporting
zero for those is treated as not ready rather than as a valid reading.
### Combined once, combined continuously, uncombined
Three distinct scopes in the same lambda, and they are not interchangeable:
- **Once** — `total_installed_battery_capacity` accumulates a single time per BMS, for the
lifetime of the boot. It represents the *installed* capacity and deliberately does not shrink
when a BMS drops offline.
- **Not continuously** — the combined counter is incremented on the transition into the combined
state, not on every tick.
- **Continuously** — the totals, bitmasks and min/max values are recomputed every round.
### `bms_seen_online_bitmask` is never cleared
It records that a BMS has been online at least once since boot. `shunt_combine.yaml` uses it to
tell "this BMS is offline" apart from "this BMS was never there" — a shunt must not be
uncombined because of a BMS the user never installed.
### Cell numbers are offset per pack
The combiner reports `cell number + (${bms_id} × 100)`, so cell 8 of BMS 1 is reported as `108`
and cell 3 of BMS 2 as `203`. This makes the pack immediately identifiable in the dashboard. It
caps a pack at 99 cells, which is well beyond any realistic configuration.
### A shunt uncombine turns the user switch off, and does not turn it back on
When a BMS mapped to a shunt goes offline, `shunt_combine.yaml` switches `Combine enabled` off
and records which BMS caused it, so the diagnostic `State` entity can say so. Re-enabling is
deliberately manual: coming back online does not automatically restore the combination, because
the SoC reference has to be trusted before it is used again.
### The `{0}` sentinel in `bms_ids`
`shunt${shunt_id}_bms_map` defaults to `'{0}'` because the vector needs a non-empty initialiser,
and the loop skips id `0` (`if (!bms_id) continue;`). Do not "clean up" the zero — it is what
makes an unmapped shunt valid.
## CAN frame catalogue
**File:** `packages/yambms/yambms_canbus.yaml`
Several `can_id` values are reused with different payloads depending on the protocol:
| CAN ID | Frame | Protocol |
|---|---|---|
| `0x359` | 5 | PYLON |
| `0x359` | 24 | Deye PCS |
| `0x371` | 11 | SEPLOS |
| `0x371` | 28 | Deye PCS |
**A frame's identity is its internal frame number, never its CAN ID.** Do not merge two blocks
because they share a CAN ID — that would break both protocols at once.
Byte order is not uniform either: `0x373` sends min cell voltage before max, `0x361` sends max
before min. Both match their respective specifications. Do not "harmonise" them.
## Frame sequencing
**File:** `packages/yambms/yambms_canbus.yaml`
Each protocol is defined as a sequence of frame numbers emitted on a fixed interval, so a full
cycle lasts `interval × sequence length` — from a few hundred milliseconds to over a second
depending on the protocol. Some inverters are sensitive to that cadence. Do not change the
interval to make protocols "consistent" with each other.
When adding a frame to a sequence, remember that the sequence length is tracked alongside the
array. Keep the two in sync, or the new frame will silently never be emitted.
## Empirical constants
Some constants were found by trial on real hardware and must not be rounded or harmonised.
<!-- TODO maintainer: list them here, in the form "do not lower <value> below <threshold>, or
<symptom>" — at minimum loop_task_stack_size, update intervals, RS485 timings. -->