Overview
The LilyGo T-Connect is a multi-functional development board based on the ESP32-S3-R8 chip, equipped with 8MB PSRAM and 16MB Flash, supporting Wi-Fi/Bluetooth dual-mode communication and RS485/CAN industrial protocols. This board is particularly well-suited for the YamBMS project thanks to its multiple communication interfaces including up to 3 RS485 ports and 1 CAN bus port.
Key Features:
- Multi-protocol Support: Supports up to three sets of RS485 and one set of CAN bus
- Industrial Communication: RS485 (UART protocol) and CAN bus (TWAI protocol)
- Flexible Configuration: Supports switching between CAN and RS485 modules
- Rich Interfaces: Integrated APA102 LED driver, QWIIC expansion interface
- Industrial Design: Wide voltage input (7V-12V DC), 4 positioning holes for easy installation
Board Specifications
The T-Connect is available as a single version with the following specifications:
| Specification | Details |
|---|---|
| Model | T-Connect |
| MCU | ESP32-S3-R8 |
| FLASH | 16MB |
| PSRAM | 8MB (Octal SPI) |
| RS485 | 3× Isolated RS485 interface |
| CAN Bus | 1× Isolated CAN interface |
| LED Driver | APA102 RGB |
| Wireless | Wi-Fi 802.11 b/g/n / Bluetooth 5.0 (BLE) |
| USB | Type-C (5V/500mA) |
| Power Input | 7V-12V DC |
| Expansion | 1× QWIIC Interface |
| Buttons | RESET + BOOT |
| Mounting | 4× 2mm positioning holes |
| Dimensions | 94×83×13mm |
Note: The T-Connect supports switching configuration between CAN and RS485 modules through onboard jumpers, allowing maximum flexibility with up to 3 RS485 ports + 1 CAN port simultaneously.
BMS Support Capacity
Based on hardware limitations and testing, this board supports:
| Communication Method | Maximum BMS | Notes |
|---|---|---|
| RS485 | Multiple BMS | Best option for monitoring many BMS units |
| UART | 3× BMS | Must be connected to the GPIOs header |
| Bluetooth (BLE) | 3× BMS | BLE stack consumes significant RAM, may cause crashes/reboots |
Note: These are theoretical limits. Not all combinations have been tested.
UART/IO Expander
It would be possible to add one or more WK2168 4x UART expander to increase the number of UART port.
Power Supply
The LilyGo T-Connect board can be powered using two methods:
Option 1: USB-C Port
- Connect a USB-C cable to the USB-C port on the board
- Provides 5V / 500mA
- Recommended for programming and testing
- Supports USB OTG functionality
Option 2: External Power Supply (DC Input)
- Voltage range: 7V to 12V DC
- Connect to the dedicated DC power terminal (usually labeled VIN/GND or PWR)
- Recommended for permanent installations and industrial environments
- Provides stable power for all communication interfaces
- Internal voltage regulator steps down to 5V and 3.3V for the ESP32-S3
Important: Do not power the board simultaneously through USB-C and the external DC terminal to avoid potential damage to the power regulation circuitry.
Port Identification
Communication Ports Layout
The T-Connect board features 4 communication ports that share pins through a switching mechanism. The board supports up to 3 RS485 ports + 1 CAN port simultaneously through proper configuration.
Pin Assignment :
| Port | TX Pin | RX Pin | Protocol |
|---|---|---|---|
| Port 1 | IO4 | IO5 | RS485 |
| Port 2 | IO6 | IO7 | RS485 |
| Port 3 | IO17 | IO18 | RS485 |
| Port 4 | IO9 | IO10 | CAN |
RS485 ports
The RS485 ports are positioned at locations No.1 to No.3 (see photo at the beginning of this page).
RS485 Terminal Pinout:
- SG - Signal Ground (for shield connection and noise immunity)
- L - RS485 A (Data+)
- H - RS485 B (Data-)
- DG - Data Ground (common reference ground)
CAN port
The CAN bus port is positioned at location No.4 (see photo at the beginning of this page).
CAN Terminal Pinout:
- SG - Signal Ground (for shield connection and noise immunity)
- L - CAN L (CAN Low)
- H - CAN H (CAN High)
- DG - Data Ground (common reference ground)
Wiring Instructions
Connecting RS485 Devices
To connect an RS485 device to any of the configured RS485 ports:
| RS485 | Terminal Block |
|---|---|
| - | SG : Shield/Signal Ground (optional but recommended) |
| A + | L (RS485 A, Data+ non-inverting) |
| B - | H (RS485 B, Data- inverting) |
| GND | DG : Data/Device Ground (optional but recommended) |
Wiring Steps:
- Ensure the port is configured for RS485 mode using the onboard jumpers
- Identify the A and B wires from your RS485 device (often labeled as D+/D- or A/B)
- Connect the A wire (D+) to the L pin of the RS485 port
- Connect the B wire (D-) to the H pin of the RS485 port
- Connect the ground wire to the DG pin for common reference (highly recommended)
- If using shielded cable, connect the shield to the SG pin (recommended for noisy environments)
Ground Connection Best Practices:
- Always connect DG (Data Ground) to provide a common reference between devices
- This prevents communication errors caused by ground potential differences
- Over long distances or in industrial environments, ground connection is critical
- RS485 can tolerate -7V to +12V common mode voltage, but proper grounding prevents issues
Shield Connection (for shielded cables):
- Connect the cable shield to SG (Signal Ground) at one end only to avoid ground loops
- In electrically noisy environments, shield connection significantly improves noise immunity
- The shield should be connected at the end closest to earth ground
Important Notes:
- RS485 polarity matters: swapping A and B will prevent communication
- If communication fails, try swapping the A and B connections
- Use twisted pair cable for RS485 connections to reduce noise and interference
- The board supports UART protocol for RS485 communication
- According to official testing: RS485 operates at 115200 baud rate with a communication distance up to 35 meters
Connecting CAN Bus Devices
To connect a CAN bus device to the CAN port:
| CAN bus | Terminal Block |
|---|---|
| - | SG : Shield/Signal Ground (optional but recommended) |
| CAN L | L (CAN Low) |
| CAN H | H (CAN High) |
| GND | DG : Data/Device Ground (optional but recommended) |
Wiring Steps:
- Ensure the port is configured for CAN mode using the onboard jumpers
- Identify the CAN H and CAN L wires from your CAN device
- Connect the CAN H wire to the H pin of the CAN port
- Connect the CAN L wire to the L pin of the CAN port
- Connect the ground wire to the DG pin for common reference (optional but recommended)
- If using shielded cable, connect the shield to the SG pin (recommended for noisy environments)
Ground Connection Best Practices:
- Always connect DG (Data Ground) to provide a common reference between devices
- Ground connection is especially important for CAN bus to prevent communication failures
- Helps maintain proper common mode voltage range
- Essential for long cable runs or installations with multiple power sources
Shield Connection (for shielded cables):
- Connect the cable shield to SG (Signal Ground) at one end only to avoid ground loops
- In electrically noisy industrial environments, shield connection is highly recommended
- Many CAN applications in automotive and industrial settings require shielded cables
Important Notes:
- CAN bus requires proper termination at both ends of the bus (see Termination Resistors section)
- Use twisted pair cable specifically designed for CAN bus (recommended impedance: 120Ω)
- The board uses TWAI (Two-Wire Automotive Interface) protocol for CAN communication
- According to official testing: CAN operates at 500 kbps with a communication distance up to 35 meters
- Maximum cable length depends on baud rate (shorter distances for higher speeds)
Additional Features
APA102 LED Driver
The T-Connect includes an onboard APA102 LED driver for controlling RGB light strips:
Pin Assignment:
- APA102_DATA: GPIO8
- APA102_CLOCK: GPIO3
This allows direct control of addressable RGB LED strips without additional hardware.
QWIIC Expansion Interface
The T-Connect features a QWIIC interface for easy connection to the QWIIC ecosystem of I2C sensors and modules, enabling simple plug-and-play expansion without soldering.
Mounting
The board includes 4× 2mm positioning holes for secure mounting in enclosures or on DIN rails, ideal for permanent industrial installations.
Bus Termination
Both RS485 and CAN bus networks require termination resistors to prevent signal reflections and ensure reliable communication.
Important Note About Termination
The T-Connect board does not appear to have built-in switchable termination resistors based on the official documentation. Users will need to add external termination resistors when required.
RS485 Termination Requirements
RS485 networks require 120Ω termination resistors at both ends of the bus:
When You Need Termination:
- At the first and last devices on the RS485 bus
- For cable runs longer than a few meters
- In electrically noisy environments
How to Add External Termination:
- Connect a 120Ω resistor between the A (L pin) and B (H pin) terminals
- Only install termination at the two endpoints of the bus
- If the T-Connect is in the middle of the network, do not add termination
CAN Bus Termination Requirements
CAN bus networks require exactly two 120Ω termination resistors (one at each end):
Critical CAN Termination Rules:
- Exactly two 120Ω resistors must be present on the entire CAN bus
- One resistor at each physical end of the bus
- Without proper termination, CAN communication will fail
- With proper termination, you should measure ~60Ω between CAN H and CAN L
How to Add External Termination:
- Connect a 120Ω resistor between CAN H (H pin) and CAN L (L pin) terminals
- Only install at the two endpoints of the CAN bus
- Many CAN devices (like inverters) have built-in termination - check your device documentation
Tip: For point-to-point connections (e.g., T-Connect ↔ Inverter), you typically need termination at both ends. Check if your inverter has built-in termination before adding external resistors.
Typical YamBMS Configuration
For a typical YamBMS setup with the LilyGo T-Connect board:
-
Power Supply:
- For bench testing: Connect USB-C cable (5V/500mA)
- For permanent installation: Connect 12V DC to the external power terminal (recommended)
-
BMS Communication:
- Connect your BMS (e.g., JK, JBD, SEPLOS, PACE, BASEN) to RS485 ports (No.1 to No.3)
- Wire according to: L=RS485 A, H=RS485 B, DG=Ground
- Connect shield to SG if using shielded cable
-
Inverter Communication:
- Connect your inverter (e.g., Deye, Sofar, Growatt, Victron) to the CAN port (No.4)
- Wire according to: L=CAN L, H=CAN H, DG=Ground
- Connect shield to SG if using shielded cable
- Typical CAN speed: 500 kbps
-
Bus Termination:
- RS485: Add external 120Ω resistor between L and H pins if the T-Connect is at the end of the RS485 bus
- CAN: Check if your inverter has built-in termination. If not, add external 120Ω resistor between CAN H and CAN L
- For point-to-point connections, you typically need termination at both devices
Additional Resources
Official Documentation
- LilyGo T-Connect Official Wiki
- LilyGo Official Store
- LilyGo Official GitHub
- T-Connect GitHub Repository
Datasheets & Schematics
Troubleshooting
No Communication on RS485
- Verify the port is configured for RS485 mode (check jumper settings)
- Verify correct A/B wiring (L=A, H=B). Try swapping if communication fails
- Check baud rate matches between devices (tested at 115200 for T-Connect)
- Add external 120Ω termination resistors at both ends of the RS485 bus if not already present
- Test cable continuity and check for damaged twisted pair cable
- Maximum tested distance: 35 meters at 115200 baud
No Communication on CAN Bus
- Verify the port is configured for CAN mode (check jumper settings)
- Verify CAN H and CAN L are correctly connected (H to H pin, L to L pin)
- Ensure exactly two 120Ω termination resistors are present on the entire CAN bus (add external resistors if needed)
- Verify CAN bus speed matches all devices (tested at 500 kbps for T-Connect)
- Measure resistance between CAN H and CAN L with multimeter (should be ~60Ω with proper termination)
- Check TWAI protocol configuration in your software
- Maximum tested distance: 35 meters at 500 kbps
Board Not Powering Up
- Check power supply voltage (7-12V DC for external power, 5V for USB-C)
- Verify polarity of external power connection (check + and - terminals)
- Try powering via USB-C for testing
- Check for short circuits on terminal blocks
- Inspect for damaged components or solder bridges
Programming/Upload Issues
- Hold down the BOOT button while uploading firmware
- Verify USB cable supports data transfer (not charge-only cable)
- Check that correct COM port is selected in Arduino IDE or PlatformIO
- Ensure USB CDC is enabled in Arduino IDE settings
- Try different USB cable or USB port on your computer
Termination Resistor Tips
- RS485: Use 1/4W 120Ω resistors between L and H pins at both bus ends
- CAN: Use 1/4W 120Ω resistors between CAN H and CAN L at both bus ends
- Verify termination with multimeter: ~60Ω for CAN, ~60Ω for RS485 (when measured across the entire bus)
- Many devices have built-in termination - check documentation before adding external resistors
Comparison with Other Boards
Waveshare ESP32-S3-RS485-CAN vs LilyGo T-Connect
| Feature | Waveshare | LilyGo T-Connect |
|---|---|---|
| RS485 Ports | 1 (isolated) | Up to 3 (isolated) |
| CAN Ports | 1 (isolated) | 1 (isolated) |
| Built-in Termination | ✅ Yes (120Ω jumper-selectable) | ❌ No (external resistors required) |
| Power Isolation | ✅ Yes | ❌ No |
| Signal Isolation | ✅ Yes (RS485 & CAN) | ✅ Yes (RS485 & CAN up to 2500V) |
| Enclosure | ✅ DIN rail ABS case included | ❌ No enclosure |
| Power Input | 7-36V DC or USB-C | 7-12V DC or USB-C |
| LED Indicators | PWR, RS485 TX/RX, CAN | PWR, APA102 support |
| Price | Moderate | Moderate |
| Best For | Single RS485 + CAN with isolation | Multiple RS485 + CAN with isolation |
Summary: The Waveshare board excels in industrial-grade protection and built-in termination, while the LilyGo offers more RS485 ports and configuration flexibility. Choose based on your specific needs:
- Waveshare: Best for harsh environments, built-in termination, ease of installation
- LilyGo: Best for multiple RS485 devices, flexible configuration, compact size