Docs: Add inferred balancing to the 1.8.1 upgrade guide

EG4 LL V2, Seplos V1/V2, Seplos V3 and JK RS485 DISPLAY now infer their
balancing state. It changes when the charge ends without any validation
error, so it belongs in the biggest changes of the upgrade guide.
This commit is contained in:
Sleeper85 committed 2026-11-10 13:20:24 +01:00
1 parent 8b24872878
commit 239f9137c3
1 file changed
+5
@@ -28,6 +28,11 @@ have made the changes below.
CAN and RS485 links can run at the same time: keep both blocks, each link with its own
`canbus_id` or `rs485_id`. The dashboard shows up to 3 CAN links and 3 RS485 links. If you only
use RS485, comment out the CAN block.
- **Balancing inferred:** EG4 LL V2, Seplos V1/V2, Seplos V3 and JK RS485 DISPLAY do not report
balancing, and YamBMS now infers it from the cell spread. While a pack is seen as balancing, the
charge only ends when the spread closes or the EOC timer expires, and the SoC stays at 98% until
then. Set `bms_balance_trigger_voltage` to your BMS's actual setting and keep `EOC timer enabled`
ON. See [Fake Equalizing](Changelog_Fake_Equalizing.md).