Update yambms_remote_packages_example.yaml
This commit is contained in:
1 parent
f357d23751
commit
9977cc5963
1 file changed
+52
-34
@@ -1,4 +1,4 @@
|
||||
# Updated : 2025.03.21
|
||||
# Updated : 2025.03.24
|
||||
# Version : 1.5.4
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
@@ -26,22 +26,62 @@ ota:
|
||||
api:
|
||||
reboot_timeout: 0s
|
||||
|
||||
# Don't forget to configure your WiFi credentials in the secrets.yaml file
|
||||
#
|
||||
# If needed, configure a static IP here
|
||||
# wifi:
|
||||
# manual_ip:
|
||||
# static_ip: 192.168.0.85
|
||||
# gateway: 192.168.0.1
|
||||
# subnet: 255.255.255.0
|
||||
# dns1: 8.8.8.8
|
||||
# dns2: 8.8.4.4
|
||||
|
||||
# +--------------------------------------+
|
||||
# | Global Settings |
|
||||
# +--------------------------------------+
|
||||
substitutions:
|
||||
name: yambms # ESP32 name / hostname
|
||||
# YamBMS settings
|
||||
# +--------------------------------------+
|
||||
# | YamBMS Settings |
|
||||
# +--------------------------------------+
|
||||
# Please read the cut-off charging logic README to understand how the YamBMS works
|
||||
yambms_id: 'yambms1'
|
||||
yambms_name: 'YamBMS 1'
|
||||
# Shunt settings
|
||||
yambms_update_interval: '1s'
|
||||
# Input numbers can be displayed as a slider or an input box, options are 'slider' or 'box'.
|
||||
yambms_input_number_mode: 'slider'
|
||||
# Please check and fill in the options below correctly according to your battery chemistry and number of cells in series.
|
||||
# These parameters are important and used for charging logic.
|
||||
# Battery Chemistry
|
||||
yambms_battery_chemistry: '1' # 1-LFP | 2-Li-ion | 3-LTO
|
||||
# Number of cells in series
|
||||
yambms_cell_count: '16'
|
||||
# Bulk / Absorption Voltage : corresponds to the Bulk voltage that will be used to charge the battery. (LFP : 55.2V = 3.45V/Cell for 16S battery)
|
||||
yambms_bulk_v: '55.2'
|
||||
# Float Voltage : corresponds to the voltage at which the battery would be maintained at the end of charge. (LFP : 53.6V = 3.35V/Cell for 16S battery)
|
||||
yambms_float_v: '53.6'
|
||||
# Rebulk voltage, voltage from which a new Bulk charge can start. (LFP : 52.8V = 3.3V/Cell for 16S battery)
|
||||
yambms_rebulk_v: '52.8'
|
||||
# Maximum time in minutes that the cut-off step can last before charging is complete
|
||||
# If your cells are properly balanced this step ends at the fastest after the `cut-off timer`
|
||||
# This timer can be deactivated with a switch
|
||||
yambms_eoc_timer: '30'
|
||||
# Time in seconds during which the end of charge conditions must be respected (cut-off + cells not equalizing)
|
||||
yambms_cutoff_timer: '60'
|
||||
# Maximum charging cycles is used to calculate the battey SOH, LF280K v3 =8000.0, LF280K v2 =6000.0, LF280=3000.0 (decimal is required)
|
||||
yambms_max_cycles: '6000.0'
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
shunt_combine_interval: '1s' # frequency at which Shunt data is combined in YamBMS
|
||||
# BMS settings
|
||||
bms_battery_chemistry: '1' # 1-LFP | 2-Li-ion | 3-LTO
|
||||
# +--------------------------------------+
|
||||
# | BMS Settings |
|
||||
# +--------------------------------------+
|
||||
bms_update_interval: '3s' # frequency at which BMS data is refreshed, going below '3s' can cause problems
|
||||
bms_combine_interval: '1s' # frequency at which BMS data is combined in YamBMS
|
||||
bms_cutoff_timer: '60s' # time during which the end of charge conditions must be respected (cut-off + cells not equalizing)
|
||||
bms_cutoff_timer: '50s' # time during which the end of charge conditions must be respected (cut-off + cells not equalizing)
|
||||
|
||||
# +--------------------------------------+
|
||||
# | Packages |
|
||||
@@ -94,31 +134,9 @@ packages:
|
||||
refresh: 0s
|
||||
files:
|
||||
- path: 'packages/yambms/yambms.yaml'
|
||||
vars:
|
||||
# Please read the cut-off charging logic README to understand how the YamBMS works
|
||||
yambms_update_interval: '1s'
|
||||
# Input numbers can be displayed as a slider or an input box, options are 'slider' or 'box'.
|
||||
yambms_input_number_mode: 'slider'
|
||||
# Please check and fill in the options below correctly according to your battery chemistry and number of cells in series.
|
||||
# These parameters are important and used for charging logic.
|
||||
# Battery Chemistry
|
||||
yambms_battery_chemistry: '1' # 1-LFP | 2-Li-ion | 3-LTO
|
||||
# Number of cells in series
|
||||
yambms_cell_count: '16'
|
||||
# Bulk / Absorption Voltage : corresponds to the Bulk voltage that will be used to charge the battery. (LFP : 55.2V = 3.45V/Cell for 16S battery)
|
||||
yambms_bulk_v: '55.2'
|
||||
# Float Voltage : corresponds to the voltage at which the battery would be maintained at the end of charge. (LFP : 53.6V = 3.35V/Cell for 16S battery)
|
||||
yambms_float_v: '53.6'
|
||||
# Rebulk voltage, voltage from which a new Bulk charge can start. (LFP : 52.8V = 3.3V/Cell for 16S battery)
|
||||
yambms_rebulk_v: '52.8'
|
||||
# Maximum time in minutes that the cut-off step can last before charging is complete
|
||||
# If your cells are properly balanced this step ends at the fastest after the `cut-off timer`
|
||||
# This timer can be deactivated with a switch
|
||||
yambms_eoc_timer: '30'
|
||||
# Time in seconds during which the end of charge conditions must be respected (cut-off + cells not equalizing)
|
||||
yambms_cutoff_timer: '60'
|
||||
# Maximum charging cycles is used to calculate the battey SOH, LF280K v3 =8000.0, LF280K v2 =6000.0, LF280=3000.0 (decimal is required)
|
||||
yambms_max_cycles: '6000.0'
|
||||
# - path: 'packages/yambms/yambms_custom.yaml'
|
||||
|
||||
# yambms_custom: !include packages/yambms/yambms_custom.yaml
|
||||
|
||||
canbus1:
|
||||
url: https://github.com/Sleeper85/esphome-yambms
|
||||
@@ -131,9 +149,9 @@ packages:
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_node1'
|
||||
canbus_light_id: 'esp_light'
|
||||
# The CANBUS link will be considered down if no response from the inverter (ID 0x305) for 5s
|
||||
# The Deye inverter sends the ACK (can_id 0x305) only when it receives the can_id 0x356
|
||||
canbus_link_timer: '6s'
|
||||
# The CANBUS link will be considered down if no response from the inverter (0x305 frame) for 5s
|
||||
# The Deye inverter sends the ACK 0x305 only when it receives the 0x356 frame.
|
||||
canbus_link_timer: '5s'
|
||||
|
||||
# +--------------------------------------+
|
||||
# | DEBUG ( logger level must be DEBUG ) |
|
||||
|
||||
Reference in new issue
Block a user