Inferred equalizing for BMS that do not report a balancing flag
Some BMS balance their cells but never expose a balancing flag, so
`bms_equalizing` stays false and the core cannot tell a pack that is still
balancing from one that has finished. This is not cosmetic : while
equalizing is true, yambms_core.yaml stops the Cut-Off timer and lets the
charge run to the EOC timer instead of terminating early.
bms_options_fake_equalizing.yaml infers that flag from the pack itself. No
absolute cell voltage is hardcoded : the anchor is bulk_voltage / cell
count, the same derivation as cell_bulk_v in yambms_core.yaml, so it
follows `yambms_battery_chemistry`, the cell count and the configured bulk
voltage automatically.
START when BOTH are true
max cell >= cell_bulk_v the pack is at the setpoint
AND (max - min) >= trigger voltage its own balancing threshold
STOP when EITHER is true
max cell < cell_bulk_v - hysteresis the pack dropped off the setpoint
OR (max - min) < trigger - delta hyst. the spread closed back below it
Only two deltas and one offset are configurable, and none of the three
depends on the chemistry - LFP, Li-ion and LTO all want the same few tens
of mV. The absolute anchor they hang off comes from the core, for free.
The delta condition is what keeps this honest : a pack that reaches the
setpoint perfectly balanced has nothing to equalize, so it reports false
and the Cut-Off timer does its job. A plain voltage comparison would report
balancing forever and terminate every charge on the EOC timer.
It extends bms<id>_bms_equalizing, the raw BMS flag, and not the combined
bms<id>_equalizing sensor. bms_base_balancer.yaml is therefore neither
modified nor duplicated, and keeps giving an external balancer priority
whenever one is online : the inference only applies when no balancer
reports for this pack.
This commit only adds the package. Nothing includes it yet, so no existing
configuration changes behaviour. Candidates sharing the same case are
Seplos V3, Seplos V1/V2, EG4 LL V2 and JK RS485 DISPLAY, whose
bms_equalizing is a hardcoded `return false;`.
This commit is contained in:
1 parent
17360765d4
commit
9dd22fa56b
19 files changed
+546
-44
No files matched your search
@@ -1,4 +1,4 @@
|
||||
# Updated : 2026.08.11
|
||||
# Updated : 2026.08.29
|
||||
# Version : 1.8.0
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
@@ -286,6 +286,7 @@ packages:
|
||||
bms_name: 'EG4-BMS 1'
|
||||
## BMS address must start at 2 with EG4 LLV2, ID 1 is a special case and has different output.
|
||||
bms_address: 2 # BMS 1 modbus address
|
||||
bms_balance_trigger_voltage: '0.030' # V. Cell spread at which the BMS balances, set yours
|
||||
bms_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# BMS 2
|
||||
- path: 'packages/bms/bms_combine_EG4_LLV2_RS485_bms_full.yaml'
|
||||
@@ -293,6 +294,7 @@ packages:
|
||||
bms_id: '2' # must be a number
|
||||
bms_name: 'EG4-BMS 2'
|
||||
bms_address: 3 # BMS 2 modbus address
|
||||
bms_balance_trigger_voltage: '0.030' # V. Cell spread at which the BMS balances, set yours
|
||||
bms_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# BMS 3
|
||||
- path: 'packages/bms/bms_combine_EG4_LLV2_RS485_bms_full.yaml'
|
||||
@@ -300,6 +302,7 @@ packages:
|
||||
bms_id: '3' # must be a number
|
||||
bms_name: 'EG4-BMS 3'
|
||||
bms_address: 4 # BMS 3 modbus address
|
||||
bms_balance_trigger_voltage: '0.030' # V. Cell spread at which the BMS balances, set yours
|
||||
bms_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
|
||||
|
||||
|
||||
@@ -71,12 +71,22 @@ The Bulk or Cut-Off **conditions must hold continuously for 10s** before the cor
|
||||
|
||||
Once the **Cut-Off phase** is entered:
|
||||
|
||||
- if the BMS reports that cells are **equalizing**, the cut-off timer is stopped: the charge is held so the balancer can work;
|
||||
- if the cells are reported — or inferred — as **equalizing**, the cut-off timer is stopped: the charge is held so the balancer can work;
|
||||
- otherwise the **cut-off timer** starts (`180s` default): if the Cut-Off conditions still hold when it expires, the **EOC** (End Of Charge) is declared;
|
||||
- in parallel, if the `EOC timer` switch is enabled, the **EOC timer** (`30min` default) guarantees that the Cut-Off phase ends at the latest when it expires, even if cells are still equalizing.
|
||||
|
||||
Returning to the Bulk phase stops both timers.
|
||||
|
||||
Some BMS balance their cells but never expose a balancing flag. YamBMS infers it for
|
||||
them, from the max cell reaching the bulk setpoint together with a cell spread that has
|
||||
reached `bms_balance_trigger_voltage`, the threshold at which that pack's own balancer
|
||||
engages, so the cut-off timer is held exactly as it would be with a
|
||||
BMS that reports the flag. A real external balancer, when one is online, always takes
|
||||
priority over the inference. This is enabled by default for Seplos V3, Seplos V1/V2,
|
||||
EG4 LL v2 and JK RS485 DISPLAY — see
|
||||
[Changelog_Fake_Equalizing.md](changelog/Changelog_Fake_Equalizing.md) for the references
|
||||
it uses and how to tune or disable it.
|
||||
|
||||
## LFP Cut-Off Values
|
||||
|
||||
- Nominal : 3.20 V
|
||||
|
||||
@@ -0,0 +1,249 @@
|
||||
# YamBMS - Changelog about the new Fake Equalizing
|
||||
|
||||
[](https://www.gnu.org/licenses/gpl-3.0)
|
||||
[](https://github.com/Sleeper85/esphome-yambms/releases/latest)
|
||||

|
||||

|
||||

|
||||
|
||||
`packages/bms/bms_options_fake_equalizing.yaml`
|
||||
|
||||
Original idea by [@haysdb](https://github.com/haysdb), who reported the problem and
|
||||
proposed a first implementation. The package shipped here is a much smaller rewrite of
|
||||
that idea — see [Why not the original pull request](#why-not-the-original-pull-request)
|
||||
at the end.
|
||||
|
||||
---
|
||||
|
||||
## 1. The problem
|
||||
|
||||
Several BMS balance their cells but never expose a balancing flag over their protocol.
|
||||
The YamBMS packages for those BMS had no choice but to declare the flag as a constant:
|
||||
|
||||
```yaml
|
||||
# equalizing
|
||||
- platform: template
|
||||
id: bms${bms_id}_bms_equalizing
|
||||
lambda: return false;
|
||||
```
|
||||
|
||||
That constant is not a neutral placeholder, it is a wrong value. Those packs *do*
|
||||
balance, and `equalizing` is not a cosmetic entity: in `yambms_core.yaml`, while it is
|
||||
true the **Cut-Off timer is stopped** and the charge is allowed to continue up to the EOC
|
||||
timer. Reporting `false` during a real balancing phase means the charge is terminated
|
||||
while the pack is still equalizing, cycle after cycle, and the user has no indication
|
||||
that anything is wrong.
|
||||
|
||||
## 2. What the package does
|
||||
|
||||
It infers the flag from the pack itself, and — this is the part that matters — **it
|
||||
hardcodes neither of the two references it needs**. Both are already in your
|
||||
configuration.
|
||||
|
||||
**The voltage reference** is the per-cell bulk setpoint:
|
||||
|
||||
```cpp
|
||||
cell_bulk_v = bulk_voltage / cell_count
|
||||
```
|
||||
|
||||
the exact derivation `yambms_core.yaml` already uses for its own end-of-charge
|
||||
comparison. It follows `yambms_battery_chemistry`, the cell count and the bulk voltage you
|
||||
configured, with no per-chemistry constant to maintain. LFP, Li-ion and LTO work out of
|
||||
the box.
|
||||
|
||||
**The spread reference** is `bms_balance_trigger_voltage` — the very spread at which your
|
||||
pack's own balancer engages. That number is not a matter of taste, and it is not the same
|
||||
from one BMS to the next: **10 mV on a JK or a Seplos, 30 mV on an EG4 LL v2**. A fixed
|
||||
constant would have fitted none of them — it would have reported balancing on a pack whose
|
||||
balancer is idle, or stayed silent on one that is working. `bms_base_balancer.yaml`
|
||||
already resolves this value to the external balancer's setting whenever one is online, and
|
||||
to the BMS's own otherwise.
|
||||
|
||||
A pack that reports no trigger voltage at all never starts. There is no basis to claim it
|
||||
is balancing, and no threshold worth inventing for it: the inference simply stays out of
|
||||
the way and the behaviour is the one you have today.
|
||||
|
||||
```
|
||||
START when BOTH are true
|
||||
max cell >= cell_bulk_v the pack is at the setpoint
|
||||
AND (max - min) >= trigger voltage its own balancing threshold
|
||||
|
||||
STOP when EITHER is true
|
||||
max cell < cell_bulk_v - hysteresis the pack dropped off the setpoint
|
||||
OR (max - min) < trigger - delta hyst. the spread closed back below it
|
||||
```
|
||||
|
||||
The **spread condition is what keeps this honest**. A pack that reaches the setpoint
|
||||
already balanced has nothing to equalize: it reports `false` and the Cut-Off timer does
|
||||
its job normally. A plain voltage comparison, with no spread condition, would report
|
||||
balancing forever and push every single charge to the EOC timer ceiling.
|
||||
|
||||
The **two hysteresis margins** exist because both references are sat *on* at top of
|
||||
charge: the max cell rests on the setpoint for a long time, and the spread hovers around
|
||||
the trigger voltage. Without them the state would toggle on every tick.
|
||||
|
||||
The spread and its threshold are compared as whole millivolts, the resolution the cells
|
||||
are reported at. This is not cosmetic: `3.450f - 3.445f` evaluates to `0.005000114`, so a
|
||||
raw float comparison against `0.005` would hold the spread above the threshold forever and
|
||||
never release the Cut-Off timer.
|
||||
|
||||
### Where it plugs in
|
||||
|
||||
The package extends `bms${bms_id}_bms_equalizing`, the **raw** BMS flag, and not the
|
||||
combined `bms${bms_id}_equalizing` sensor. Consequence: `bms_base_balancer.yaml` is
|
||||
neither modified nor duplicated, and it keeps giving an **external balancer priority**
|
||||
whenever one is online. If you run a NEEY or a Modbus balancer on that `bms_id`, its
|
||||
reading wins; the inference only applies when no balancer reports for this pack.
|
||||
|
||||
## 3. Which BMS are concerned
|
||||
|
||||
The four BMS below shipped a hardcoded `return false;`. The package is now **included by
|
||||
default** for them — there is nothing to add to your YAML:
|
||||
|
||||
| BMS | Packages |
|
||||
|---|---|
|
||||
| EG4 LL V2 | `bms_combine_EG4_LLV2_RS485_bms_full.yaml`<br>`bms_modbus_EG4_LLV2_RS485_bms_full.yaml` |
|
||||
| Seplos V1 V2 | `bms_combine_SEPLOS_V1_V2_RS485_bms_full.yaml`<br>`bms_modbus_SEPLOS_V1_V2_RS485_bms_full.yaml` |
|
||||
| Seplos V3 | `bms_combine_SEPLOS_V3_RS485_bms_full.yaml`<br>`bms_modbus_SEPLOS_V3_RS485_bms_full.yaml` |
|
||||
| JK RS485 DISPLAY | `bms_combine_JK_RS485_DISPLAY_full.yaml` |
|
||||
|
||||
The `bms_modbus_*` variants are the multi-node server packages, so a secondary node
|
||||
relays the inferred flag to the client exactly like a real one.
|
||||
|
||||
The **Fake BMS** (`bms_combine_FAKE.yaml`, `_FAKE_extended.yaml`, `_DEMO.yaml`) also uses
|
||||
it now. It previously carried an inline voltage comparison with no spread condition,
|
||||
which the package replaces.
|
||||
|
||||
### BMS that are *not* concerned
|
||||
|
||||
- **JK** (BLE, RS485 Modbus, UART 4G-GPS), **JBD**, **Ecoworthy**, **PACE**, **Deye CAN**
|
||||
and the YamBMS Modbus client node all report a real balancing flag. Nothing changes.
|
||||
- **BASEN** already infers the flag inline, from its own `balance_starting_voltage` and
|
||||
`balance_trigger_voltage` reported by the BMS. Those are a better source than a
|
||||
derived anchor, so it is left as is.
|
||||
- **KS BLE** derives the flag from the balanced-cell bitmask, which is real information.
|
||||
|
||||
The package can be added manually to another BMS, once for each `bms_id`:
|
||||
|
||||
```yaml
|
||||
- path: packages/bms/bms_options_fake_equalizing.yaml
|
||||
vars:
|
||||
bms_id: '1' # must be a number
|
||||
```
|
||||
|
||||
but only where `bms<id>_bms_equalizing` is declared as a plain `platform: template`
|
||||
binary_sensor, which is what it replaces the lambda of. A BMS that exposes the flag
|
||||
through its own component — `jk_bms_ble`, `jbd_bms`, `modbus_controller` and the like —
|
||||
cannot be extended this way: those platforms take no `lambda:`, and the configuration
|
||||
will not validate. That is not a real limitation, since those are precisely the BMS that
|
||||
already report a genuine flag.
|
||||
|
||||
## 4. Tuning
|
||||
|
||||
### The one setting that matters: `bms_balance_trigger_voltage`
|
||||
|
||||
This is your BMS's own balancing threshold, and it is the spread the inference compares
|
||||
against. Some BMS report it over their protocol; those that cannot expose it as a var to
|
||||
declare at import — **Seplos V1/V2, Seplos V3, EG4 LL v2 and JK RS485 DISPLAY all work
|
||||
that way**. It also feeds `Auto CVL`, so it was already worth getting right.
|
||||
|
||||
EG4 LL v2 and JK RS485 DISPLAY used a hard-coded value.
|
||||
They now expose it like the others with the following default values:
|
||||
|
||||
| BMS | Default |
|
||||
|---|---|
|
||||
| EG4 LL V2 | 0.03 |
|
||||
| SEPLOS V1 V2 | 0.01 |
|
||||
| SEPLOS V3 | 0.01 |
|
||||
| JK RS485 DISPLAY | 0.01 |
|
||||
|
||||
```yaml
|
||||
# BMS 1
|
||||
- path: 'packages/bms/bms_combine_your_BMS.yaml'
|
||||
vars:
|
||||
bms_id: '1'
|
||||
# ... other vars of your BMS ...
|
||||
bms_balance_trigger_voltage: '0.010' # V. Your BMS's balancing threshold
|
||||
bms_fake_equalizing_enabled: 'true' # Optional : true/fasle, true by default
|
||||
bms_fake_equalizing_hysteresis: '0.030' # Optional : 0.030 by default
|
||||
bms_fake_equalizing_delta_hysteresis: '0.002' # Optional : 0.002 by default
|
||||
```
|
||||
|
||||
Set it to what your BMS is actually configured for. On a JK you can read and change it in
|
||||
the BMS itself; on an EG4 it may not be adjustable, in which case leave the default.
|
||||
|
||||
### The rest
|
||||
|
||||
An on/off switch and two margins around the references. No threshold among them, and the
|
||||
defaults are fine for any pack.
|
||||
|
||||
| Substitution | Default | Meaning |
|
||||
|---|---|---|
|
||||
| `bms_fake_equalizing_enabled` | `'true'` | set to `'false'` to turn the inference off for this BMS |
|
||||
| `bms_fake_equalizing_hysteresis` | `0.030` | how far below the bulk setpoint the max cell may fall before balancing stops |
|
||||
| `bms_fake_equalizing_delta_hysteresis` | `0.002` | how far below the trigger voltage the spread may fall before balancing stops |
|
||||
|
||||
All of them can be passed per BMS as above, or set once for every BMS in the root
|
||||
`substitutions:` block. The spread values are resolved to whole millivolts, the resolution
|
||||
the cells are reported at, so a value finer than `0.001` has no effect.
|
||||
|
||||
**To disable the inference** on a BMS without editing any package:
|
||||
|
||||
```yaml
|
||||
bms_fake_equalizing_enabled: 'false'
|
||||
```
|
||||
|
||||
The flag then reports the constant `false` its package used to hardcode, which is the
|
||||
behaviour you had before this release. Do *not* try to disable it by raising
|
||||
`bms_balance_trigger_voltage` instead — that value also feeds `Auto CVL`, where it means
|
||||
something else entirely: how far the highest cell may overshoot the per-cell setpoint
|
||||
before the PI clamps.
|
||||
|
||||
## 5. What changes for you on upgrade
|
||||
|
||||
If you own one of the four BMS above, the `balancing` entity will now turn on at the top
|
||||
of charge as soon as your cells are spread by as much as your BMS's own
|
||||
`bms_balance_trigger_voltage` — 10 mV on a Seplos or a JK, 30 mV on an EG4 unless you
|
||||
declared otherwise. The charge then runs until the spread closes back below that, or
|
||||
until the EOC timer expires, instead of being cut short by the Cut-Off timer. That is the
|
||||
intended fix, but it *is* a change in charge termination, so watch a couple of cycles
|
||||
after updating.
|
||||
|
||||
The risk is bounded on the safe side. A false positive can only extend the charge up to
|
||||
the EOC timer, which exists for exactly that purpose. A false negative simply restores
|
||||
the previous behaviour.
|
||||
|
||||
## Why not the original pull request
|
||||
|
||||
[@haysdb](https://github.com/haysdb) opened
|
||||
[PR #304](https://github.com/Sleeper85/esphome-yambms/pull/304) with a *Fake Balancer*
|
||||
package. The diagnosis was right and the idea is his. The implementation was shaped
|
||||
around his own setup — a NEEY balancer that does not run every day — and carried more
|
||||
than YamBMS needs:
|
||||
|
||||
- **Absolute thresholds as entities.** Four `number` entities held the start / sleep /
|
||||
trigger / stop-diff voltages, hardcoded to LFP values (3.45 / 3.42 V). They lived
|
||||
alongside the bulk voltage the user had already configured, so the same physical
|
||||
setpoint existed twice and could drift apart. Taking the voltage reference from
|
||||
`bulk_voltage / cell_count` and the spread reference from
|
||||
`bms_balance_trigger_voltage` removes the duplication entirely, and makes the
|
||||
package track each BMS instead of a constant that fits none of them.
|
||||
- **A companion stub package.** The lambda referenced `balancer${bms_id}_online_status`
|
||||
and `balancer${bms_id}_equalizing`, which only exist when a balancer package is
|
||||
included, so a second package had to declare two always-false sensors just to make it
|
||||
compile without one. Reading the raw BMS flag instead makes the stub unnecessary.
|
||||
- **A duplicated core lambda.** It extended the *combined* `bms${bms_id}_equalizing` and
|
||||
recopied the branch from `bms_base_balancer.yaml` to add its OR. Extending the raw flag
|
||||
keeps a single copy of that logic.
|
||||
- **A side effect on another entity.** The interval wrote
|
||||
`bms${bms_id}_var_ext_balancer_online = real_online || fake_eq`, which made
|
||||
`bms_base_balancer.yaml` report the external balancer's trigger voltage — `0.000 V`
|
||||
when no balancer had ever been online.
|
||||
- **Eight entities and a sub-device per BMS**, for a function that needs none.
|
||||
|
||||
The `Force` switch and the `Max Run Time` number were dropped as well: they answer the
|
||||
need to launch a weekly top-balance by hand when the hardware balancer is idle, which is
|
||||
a balancer feature rather than a BMS one.
|
||||
|
||||
Thanks to @haysdb for finding the problem and for the threshold model — start and stop on
|
||||
a spread with hysteresis is his, and it is the part that makes the inference trustworthy.
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.02.16
|
||||
# Version : 1.1.4
|
||||
# Updated : 2026.08.29
|
||||
# Version : 1.1.5
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -39,6 +39,7 @@ packages:
|
||||
bms_name: 'EG4-BMS 1'
|
||||
## BMS address must start at 2 with EG4 LLV2, ID 1 is a special case and has different output.
|
||||
bms_address: 2 # BMS 1 modbus address
|
||||
bms_balance_trigger_voltage: '0.030' # V. Cell spread at which the BMS balances, set yours
|
||||
bms_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
|
||||
bms2: !include
|
||||
@@ -47,6 +48,7 @@ packages:
|
||||
bms_id: '2' # must be a number
|
||||
bms_name: 'EG4-BMS 2'
|
||||
bms_address: 3 # BMS 2 modbus address
|
||||
bms_balance_trigger_voltage: '0.030' # V. Cell spread at which the BMS balances, set yours
|
||||
bms_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
|
||||
bms3: !include
|
||||
@@ -55,4 +57,5 @@ packages:
|
||||
bms_id: '3' # must be a number
|
||||
bms_name: 'EG4-BMS 3'
|
||||
bms_address: 4 # BMS 3 modbus address
|
||||
bms_balance_trigger_voltage: '0.030' # V. Cell spread at which the BMS balances, set yours
|
||||
bms_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.02.16
|
||||
# Version : 1.1.4
|
||||
# Updated : 2026.08.29
|
||||
# Version : 1.1.5
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -43,6 +43,7 @@
|
||||
bms_name: 'EG4-BMS 1'
|
||||
## BMS address must start at 2 with EG4 LLV2, ID 1 is a special case and has different output.
|
||||
bms_address: 2 # BMS 1 modbus address
|
||||
bms_balance_trigger_voltage: '0.030' # V. Cell spread at which the BMS balances, set yours
|
||||
bms_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# BMS 2
|
||||
- path: 'packages/bms/bms_combine_EG4_LLV2_RS485_bms_full.yaml'
|
||||
@@ -50,6 +51,7 @@
|
||||
bms_id: '2' # must be a number
|
||||
bms_name: 'EG4-BMS 2'
|
||||
bms_address: 3 # BMS 2 modbus address
|
||||
bms_balance_trigger_voltage: '0.030' # V. Cell spread at which the BMS balances, set yours
|
||||
bms_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# BMS 3
|
||||
- path: 'packages/bms/bms_combine_EG4_LLV2_RS485_bms_full.yaml'
|
||||
@@ -57,4 +59,5 @@
|
||||
bms_id: '2' # must be a number
|
||||
bms_name: 'EG4-BMS 3'
|
||||
bms_address: 4 # BMS 3 modbus address
|
||||
bms_balance_trigger_voltage: '0.030' # V. Cell spread at which the BMS balances, set yours
|
||||
bms_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.14
|
||||
# Version : 1.1.2
|
||||
# Updated : 2026.08.28
|
||||
# Version : 1.1.3
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -20,6 +20,7 @@
|
||||
packages:
|
||||
bms_sensors: !include bms_sensors_FAKE.yaml
|
||||
bms_numbers: !include bms_sensors_FAKE_extended.yaml
|
||||
bms_fake_equalizing: !include bms_options_fake_equalizing.yaml
|
||||
bms_demo_cs: !include bms_demo_charge_simulation.yaml
|
||||
bms_combine: !include
|
||||
file: bms_combine.yaml
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.14
|
||||
# Version : 1.1.3
|
||||
# Updated : 2026.08.28
|
||||
# Version : 1.1.4
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -21,6 +21,7 @@
|
||||
|
||||
packages:
|
||||
bms_sensors: !include bms_sensors_EG4_LLV2_RS485_bms_full.yaml
|
||||
bms_fake_equalizing: !include bms_options_fake_equalizing.yaml
|
||||
bms_combine: !include
|
||||
file: bms_combine.yaml
|
||||
vars:
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.14
|
||||
# Version : 1.1.2
|
||||
# Updated : 2026.08.28
|
||||
# Version : 1.1.3
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -19,6 +19,7 @@
|
||||
|
||||
packages:
|
||||
bms_sensors: !include bms_sensors_FAKE.yaml
|
||||
bms_fake_equalizing: !include bms_options_fake_equalizing.yaml
|
||||
bms_combine: !include
|
||||
file: bms_combine.yaml
|
||||
vars:
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.14
|
||||
# Version : 1.1.2
|
||||
# Updated : 2026.08.28
|
||||
# Version : 1.1.3
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -20,6 +20,7 @@
|
||||
packages:
|
||||
bms_sensors: !include bms_sensors_FAKE.yaml
|
||||
bms_numbers: !include bms_sensors_FAKE_extended.yaml
|
||||
bms_fake_equalizing: !include bms_options_fake_equalizing.yaml
|
||||
bms_combine: !include
|
||||
file: bms_combine.yaml
|
||||
vars:
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.14
|
||||
# Version : 1.2.0
|
||||
# Updated : 2026.08.29
|
||||
# Version : 1.2.2
|
||||
# GitHub : https://github.com/syssi/esphome-jk-bms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -19,6 +19,7 @@
|
||||
|
||||
packages:
|
||||
bms_base: !include bms_base.yaml
|
||||
bms_fake_equalizing: !include bms_options_fake_equalizing.yaml
|
||||
bms_combine: !include
|
||||
file: bms_combine.yaml
|
||||
vars:
|
||||
@@ -27,6 +28,13 @@ packages:
|
||||
bms_temperature_sensor: !include bms_temperature_sensor_2.yaml
|
||||
bms_battery_soh: !include bms_base_battery_soh.yaml
|
||||
|
||||
substitutions:
|
||||
# (V) cell spread at which this BMS starts balancing. Not readable over the display
|
||||
# port, so declare your unit's actual setting at import. Used by 'Auto CVL' and, when
|
||||
# bms_options_fake_equalizing.yaml is included, as the spread reference for the
|
||||
# inferred balancing flag.
|
||||
bms_balance_trigger_voltage: '0.01'
|
||||
|
||||
# +--------------------------------------+
|
||||
# | DISPLAY port schematic |
|
||||
# +--------------------------------------+
|
||||
@@ -193,7 +201,7 @@ sensor:
|
||||
device_id: bms_${bms_id}
|
||||
# name: "state of charge"
|
||||
delta_cell_voltage:
|
||||
device_id: bms_${bms_id}
|
||||
device_id: bms_${bms_id}
|
||||
name: "delta cell voltage"
|
||||
mosfet_temperature:
|
||||
id: bms${bms_id}_temperature_sensor_1
|
||||
@@ -384,7 +392,7 @@ sensor:
|
||||
- or:
|
||||
- throttle: 10s
|
||||
- delta: 0.001
|
||||
lambda: return 0.005;
|
||||
lambda: return ${bms_balance_trigger_voltage};
|
||||
|
||||
# FAKE charging_cycles
|
||||
- platform: template
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.14
|
||||
# Version : 1.1.2
|
||||
# Updated : 2026.08.28
|
||||
# Version : 1.1.3
|
||||
# GitHub : https://github.com/syssi/esphome-seplos-bms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -19,6 +19,7 @@
|
||||
|
||||
packages:
|
||||
bms_sensors: !include bms_sensors_SEPLOS_V1_V2_RS485_bms_full.yaml
|
||||
bms_fake_equalizing: !include bms_options_fake_equalizing.yaml
|
||||
bms_combine: !include
|
||||
file: bms_combine.yaml
|
||||
vars:
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.14
|
||||
# Version : 1.1.2
|
||||
# Updated : 2026.08.28
|
||||
# Version : 1.1.3
|
||||
# GitHub : https://github.com/syssi/esphome-seplos-bms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -19,6 +19,7 @@
|
||||
|
||||
packages:
|
||||
bms_sensors: !include bms_sensors_SEPLOS_V3_RS485_bms_full.yaml
|
||||
bms_fake_equalizing: !include bms_options_fake_equalizing.yaml
|
||||
bms_combine: !include
|
||||
file: bms_combine.yaml
|
||||
vars:
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.06.29
|
||||
# Version : 1.1.3
|
||||
# Updated : 2026.08.29
|
||||
# Version : 1.1.4
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -38,6 +38,9 @@ substitutions:
|
||||
min_temperature: '4.8'
|
||||
max_temperature: '5.0'
|
||||
delta_cell_voltage: '0.005'
|
||||
# Spread held during the two balancing steps. Must stay above this BMS's
|
||||
# `bms_balance_trigger_voltage` for the inferred equalizing flag to assert.
|
||||
delta_cell_voltage_balancing: '0.020'
|
||||
|
||||
switch:
|
||||
# DEMO switch
|
||||
@@ -118,14 +121,14 @@ interval:
|
||||
// Step 4 : 98% (10sec)
|
||||
id(bms${bms_id}_state_of_charge).publish_state(98);
|
||||
id(bms${bms_id}_current).publish_state(5);
|
||||
id(bms${bms_id}_min_cell_voltage).publish_state(requested_cvl / cell_count + 0.01 - ${delta_cell_voltage});
|
||||
id(bms${bms_id}_min_cell_voltage).publish_state(requested_cvl / cell_count + 0.01 - ${delta_cell_voltage_balancing});
|
||||
id(bms${bms_id}_max_cell_voltage).publish_state(requested_cvl / cell_count + 0.01); // equalizing
|
||||
}
|
||||
else if (seconds <= 5 * step_sec) { // Entering Cut-off phase...
|
||||
// Step 5 : 99% (10sec)
|
||||
id(bms${bms_id}_state_of_charge).publish_state(99);
|
||||
id(bms${bms_id}_current).publish_state(3.5);
|
||||
id(bms${bms_id}_min_cell_voltage).publish_state(requested_cvl / cell_count + 0.005 - ${delta_cell_voltage});
|
||||
id(bms${bms_id}_min_cell_voltage).publish_state(requested_cvl / cell_count + 0.005 - ${delta_cell_voltage_balancing});
|
||||
id(bms${bms_id}_max_cell_voltage).publish_state(requested_cvl / cell_count + 0.005); // equalizing
|
||||
}
|
||||
else if (seconds <= 15 * step_sec) { // End of Cut-off phase...
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.14
|
||||
# Version : 1.1.4
|
||||
# Updated : 2026.08.28
|
||||
# Version : 1.1.5
|
||||
# GitHub : https://github.com/syssi/esphome-jk-bms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -19,4 +19,5 @@
|
||||
|
||||
packages:
|
||||
bms_sensors: !include bms_sensors_EG4_LLV2_RS485_bms_full.yaml
|
||||
bms_fake_equalizing: !include bms_options_fake_equalizing.yaml
|
||||
bms_combine: !include bms_modbus_server.yaml
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.14
|
||||
# Version : 1.1.2
|
||||
# Updated : 2026.08.28
|
||||
# Version : 1.1.3
|
||||
# GitHub : https://github.com/syssi/esphome-pace-bms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -19,4 +19,5 @@
|
||||
|
||||
packages:
|
||||
bms_sensors: !include bms_sensors_SEPLOS_V1_V2_RS485_bms_full.yaml
|
||||
bms_fake_equalizing: !include bms_options_fake_equalizing.yaml
|
||||
bms_combine: !include bms_modbus_server.yaml
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.14
|
||||
# Version : 1.1.2
|
||||
# Updated : 2026.08.28
|
||||
# Version : 1.1.3
|
||||
# GitHub : https://github.com/syssi/esphome-pace-bms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -19,4 +19,5 @@
|
||||
|
||||
packages:
|
||||
bms_sensors: !include bms_sensors_SEPLOS_V3_RS485_bms_full.yaml
|
||||
bms_fake_equalizing: !include bms_options_fake_equalizing.yaml
|
||||
bms_combine: !include bms_modbus_server.yaml
|
||||
@@ -0,0 +1,214 @@
|
||||
# Updated : 2026.08.29
|
||||
# Version : 1.1.0
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
|
||||
# This YAML is free software: you can redistribute it and/or
|
||||
# modify it under the terms of the GNU General Public License
|
||||
# as published by the Free Software Foundation, either version 3
|
||||
# of the License, or (at your option) any later version.
|
||||
#
|
||||
# This program is distributed in the hope that it will be useful,
|
||||
# but WITHOUT ANY WARRANTY; without even the implied warranty of
|
||||
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
|
||||
# See the GNU General Public License for more details.
|
||||
#
|
||||
# You should have received a copy of the GNU General Public License
|
||||
# along with this program. If not, see <http://www.gnu.org/licenses/gpl.html>.
|
||||
|
||||
|
||||
|
||||
# +--------------------------------------------------------------------------------+
|
||||
# | Fake Equalizing - infer the balancing flag a BMS does not report |
|
||||
# +--------------------------------------------------------------------------------+
|
||||
# | Some BMS balance their cells but never expose a balancing flag, so
|
||||
# | `bms_equalizing` stays false and the core cannot tell a pack that is still
|
||||
# | balancing from one that has finished. That matters : while equalizing is true
|
||||
# | the core stops the Cut-Off timer (yambms_core.yaml) and lets the charge run to
|
||||
# | the EOC timer instead of terminating early.
|
||||
# |
|
||||
# | This package infers that flag from the pack itself, and hardcodes neither of the
|
||||
# | two references it needs :
|
||||
# |
|
||||
# | the voltage anchor is the per-cell bulk setpoint, `bulk voltage / cell count`,
|
||||
# | the same derivation as cell_bulk_v in yambms_core.yaml, so it follows
|
||||
# | `yambms_battery_chemistry`, the cell count and the configured bulk voltage ;
|
||||
# |
|
||||
# | the spread anchor is `bms${bms_id}_balance_trigger_voltage`, the very spread at
|
||||
# | which this pack's own balancer engages. bms_base_balancer.yaml resolves it to
|
||||
# | the external balancer's value whenever one is online, to the BMS's otherwise.
|
||||
# |
|
||||
# | START when BOTH are true :
|
||||
# | max cell >= cell bulk setpoint the pack is at the setpoint
|
||||
# | AND (max - min) >= trigger voltage the pack's own balancing threshold
|
||||
# |
|
||||
# | STOP when EITHER is true :
|
||||
# | max cell < setpoint - hysteresis the pack dropped off the setpoint
|
||||
# | OR (max - min) < trigger - delta hyst. the spread closed back below it
|
||||
# |
|
||||
# | Nothing is configurable but an on/off switch and the two hysteresis margins, so
|
||||
# | the inference tracks the hardware instead of a constant that would fit no BMS in
|
||||
# | particular : the
|
||||
# | balance trigger voltage is 10 mV on a JK or a Seplos, 30 mV on an EG4. A pack that
|
||||
# | reports none at all never starts - there is no threshold worth inventing for it.
|
||||
# |
|
||||
# | The spread condition is what keeps this honest : a pack that reaches the setpoint
|
||||
# | already balanced has nothing to equalize, so it reports false and the Cut-Off
|
||||
# | timer does its job. A plain voltage comparison would report balancing forever and
|
||||
# | terminate the charge on the EOC timer every cycle.
|
||||
# |
|
||||
# | It extends `bms_equalizing`, the RAW BMS flag, not the combined
|
||||
# | `bms${bms_id}_equalizing` sensor. So bms_base_balancer.yaml is untouched and
|
||||
# | keeps giving an external balancer (NEEY, modbus client) priority whenever one
|
||||
# | is online : the inference only applies when no balancer reports for this pack.
|
||||
# |
|
||||
# | REQUIRES the BMS package it is included alongside to expose :
|
||||
# |
|
||||
# | bms${bms_id}_bms_equalizing the raw flag, declared as a template
|
||||
# | binary_sensor (extended here)
|
||||
# | bms${bms_id}_max_cell_voltage
|
||||
# | bms${bms_id}_min_cell_voltage
|
||||
# |
|
||||
# | plus, both always present :
|
||||
# |
|
||||
# | bms${bms_id}_balance_trigger_voltage from bms_base_balancer.yaml
|
||||
# | yambms${yambms_id}_bulk_voltage from the core
|
||||
# | yambms${yambms_id}_cell_count
|
||||
# |
|
||||
# | A BMS that cannot read its balancing threshold over its protocol exposes it as the
|
||||
# | `bms_balance_trigger_voltage` var instead, to be set at import - Seplos V1/V2 and
|
||||
# | V3, EG4 LL v2 and JK RS485 DISPLAY all work that way. Declare your unit's actual
|
||||
# | setting there : it is what this package compares the spread against.
|
||||
# +--------------------------------------------------------------------------------+
|
||||
# | Included by default - these BMS need nothing added to your YAML
|
||||
# +--------------------------------------------------------------------------------+
|
||||
# |
|
||||
# | EG4 LL V2 bms_combine_EG4_LLV2_RS485_bms_full.yaml
|
||||
# | bms_modbus_EG4_LLV2_RS485_bms_full.yaml
|
||||
# | Seplos V1 V2 bms_combine_SEPLOS_V1_V2_RS485_bms_full.yaml
|
||||
# | bms_modbus_SEPLOS_V1_V2_RS485_bms_full.yaml
|
||||
# | Seplos V3 bms_combine_SEPLOS_V3_RS485_bms_full.yaml
|
||||
# | bms_modbus_SEPLOS_V3_RS485_bms_full.yaml
|
||||
# | JK RS485 DISP. bms_combine_JK_RS485_DISPLAY_full.yaml
|
||||
# | Fake BMS bms_combine_FAKE.yaml, _FAKE_extended.yaml, _DEMO.yaml
|
||||
# |
|
||||
# | The four real BMS above declared `bms_equalizing` as a hardcoded
|
||||
# | `return false;` : they do balance, they just never say so. The Fake BMS used
|
||||
# | to carry an inline voltage comparison, which this package replaces.
|
||||
# +--------------------------------------------------------------------------------+
|
||||
# | Adding it to another BMS - once for each bms_id
|
||||
# +--------------------------------------------------------------------------------+
|
||||
#
|
||||
# - path: packages/bms/bms_options_fake_equalizing.yaml
|
||||
# vars:
|
||||
# bms_id: '1' # must be a number
|
||||
#
|
||||
# | Only where `bms${bms_id}_bms_equalizing` is declared as a plain
|
||||
# | `platform: template` binary_sensor, since this replaces its lambda. A BMS that
|
||||
# | exposes the flag through its own component - jk_bms_ble, jbd_bms,
|
||||
# | modbus_controller and the like - cannot be extended this way : those platforms
|
||||
# | take no `lambda:` and the configuration will not validate. No real loss, as those
|
||||
# | are exactly the BMS that already report a genuine flag.
|
||||
#
|
||||
# +--------------------------------------------------------------------------------+
|
||||
# | Tuning - add the vars to your BMS include, they override the defaults below
|
||||
# +--------------------------------------------------------------------------------+
|
||||
#
|
||||
# # BMS 1
|
||||
# - path: 'packages/bms/bms_combine_your_BMS.yaml'
|
||||
# vars:
|
||||
# bms_id: '1'
|
||||
# # ... other vars of your BMS ...
|
||||
# bms_balance_trigger_voltage: '0.010' # V. Your BMS's balancing threshold
|
||||
# bms_fake_equalizing_enabled: 'true' # Optional : true/fasle, true by default
|
||||
# bms_fake_equalizing_hysteresis: '0.030' # Optional : 0.030 by default
|
||||
# bms_fake_equalizing_delta_hysteresis: '0.002' # Optional : 0.002 by default
|
||||
#
|
||||
# | The one worth setting is `bms_balance_trigger_voltage` : it is your BMS's own
|
||||
# | balancing threshold, it also feeds 'Auto CVL', and the rest is fine as it is.
|
||||
# |
|
||||
# | Or set them once for every BMS in the root `substitutions:` block.
|
||||
# | To turn the inference off on one BMS : bms_fake_equalizing_enabled: 'false'
|
||||
# +--------------------------------------------------------------------------------+
|
||||
|
||||
|
||||
|
||||
substitutions:
|
||||
# +--------------------------------------------------------------------------------+
|
||||
# | Nothing here is a threshold : the two references come from elsewhere.
|
||||
# | The voltage anchor is the per-cell bulk setpoint, from the core.
|
||||
# | The spread anchor is `bms_balance_trigger_voltage`, from the BMS itself.
|
||||
# | What is left is an on/off switch and the two hysteresis margins.
|
||||
# +--------------------------------------------------------------------------------+
|
||||
# 'true' / 'false'. Set to 'false' to turn the inference off for this BMS : the flag
|
||||
# goes back to the constant false its package used to report. Needed because the
|
||||
# package is included by default for the BMS that cannot report the flag, and a
|
||||
# Remote Packages user cannot edit a package to drop it.
|
||||
bms_fake_equalizing_enabled: 'true'
|
||||
# (V) how far below the bulk setpoint the max cell may fall before balancing stops.
|
||||
# Without it the state toggles on every tick while the max cell sits on the setpoint.
|
||||
bms_fake_equalizing_hysteresis: '0.030'
|
||||
# (V) how far below the balance trigger voltage the spread may fall before balancing
|
||||
# stops. Resolved to whole millivolts, the resolution the cells are reported at :
|
||||
# a value finer than 0.001 has no effect.
|
||||
bms_fake_equalizing_delta_hysteresis: '0.002'
|
||||
|
||||
binary_sensor:
|
||||
# equalizing (inferred)
|
||||
- id: !extend bms${bms_id}_bms_equalizing
|
||||
lambda: |-
|
||||
static bool balancing = false;
|
||||
|
||||
// Turned off : report the constant false this BMS package used to hardcode.
|
||||
if (!${bms_fake_equalizing_enabled})
|
||||
return false;
|
||||
|
||||
float cell_count = id(yambms${yambms_id}_cell_count).state;
|
||||
float bulk_v = id(yambms${yambms_id}_bulk_voltage).state;
|
||||
float max_cell_v = id(bms${bms_id}_max_cell_voltage).state;
|
||||
float min_cell_v = id(bms${bms_id}_min_cell_voltage).state;
|
||||
float trigger_v = id(bms${bms_id}_balance_trigger_voltage).state;
|
||||
|
||||
// The spread reference is the balance trigger voltage : the very spread at which
|
||||
// this pack's own balancer engages, so the inference tracks the hardware instead
|
||||
// of a constant that would fit no BMS in particular. bms_base_balancer.yaml
|
||||
// resolves it to the external balancer's value whenever one is online.
|
||||
//
|
||||
// Hold the last state while any reference is missing, rather than dropping out of
|
||||
// balancing on a single missing reading and releasing the Cut-Off timer. A pack
|
||||
// that never reports a trigger voltage never starts : there is no basis to claim
|
||||
// it is balancing, and no threshold worth inventing for it. Some packages do
|
||||
// publish 0 before their first read (PACE, the Modbus client node), which this
|
||||
// covers as well.
|
||||
if (isnan(cell_count) || cell_count <= 0 || isnan(bulk_v) ||
|
||||
isnan(max_cell_v) || isnan(min_cell_v) ||
|
||||
isnan(trigger_v) || trigger_v <= 0.0f)
|
||||
return balancing;
|
||||
|
||||
// Same derivation as cell_bulk_v in yambms_core.yaml
|
||||
float cell_bulk_v = bulk_v / cell_count;
|
||||
|
||||
// The spread and its threshold are compared as whole millivolts, which is the
|
||||
// resolution the cells are reported at. A float subtraction of two mV-aligned
|
||||
// readings lands a fraction of a uV off - 3.450 - 3.445 gives 0.005000114 - which
|
||||
// would hold the spread just above the threshold forever and never release the
|
||||
// Cut-Off timer. The voltage gates keep their float comparison : their margin is
|
||||
// the hysteresis, orders of magnitude above that error.
|
||||
int delta_mv = (int) roundf((max_cell_v - min_cell_v) * 1000.0f);
|
||||
int trigger_mv = (int) roundf(trigger_v * 1000.0f);
|
||||
int hyst_mv = (int) roundf(${bms_fake_equalizing_delta_hysteresis} * 1000.0f);
|
||||
|
||||
if (!balancing)
|
||||
{
|
||||
// Start : at the setpoint AND spread up to what makes this BMS balance
|
||||
balancing = (max_cell_v >= cell_bulk_v) && (delta_mv >= trigger_mv);
|
||||
}
|
||||
else
|
||||
{
|
||||
// Stop : fell off the setpoint OR the spread closed back below the trigger
|
||||
balancing = (max_cell_v >= cell_bulk_v - ${bms_fake_equalizing_hysteresis}) &&
|
||||
(delta_mv >= trigger_mv - hyst_mv);
|
||||
}
|
||||
|
||||
return balancing;
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.15
|
||||
# Version : 2.0.4
|
||||
# Updated : 2026.08.29
|
||||
# Version : 2.0.5
|
||||
# GitHub : https://github.com/RAR/esphome-eg4-bms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -22,6 +22,13 @@ packages:
|
||||
bms_temperature_sensor: !include bms_temperature_sensor_4.yaml
|
||||
bms_errors_bitmask: !include bms_errors_bitmask_EG4_LLV2_RS485_Modbus.yaml
|
||||
|
||||
substitutions:
|
||||
# (V) cell spread at which this BMS starts balancing. Not readable over the protocol,
|
||||
# so declare your unit's actual setting at import. Used by 'Auto CVL' and, when
|
||||
# bms_options_fake_equalizing.yaml is included, as the spread reference for the
|
||||
# inferred balancing flag.
|
||||
bms_balance_trigger_voltage: '0.030'
|
||||
|
||||
# +--------------------------------------+
|
||||
# | Component settings |
|
||||
# +--------------------------------------+
|
||||
@@ -281,7 +288,7 @@ sensor:
|
||||
- or:
|
||||
- throttle: 10s
|
||||
- delta: 0.001
|
||||
lambda: return 0.030;
|
||||
lambda: return ${bms_balance_trigger_voltage};
|
||||
|
||||
- platform: template
|
||||
id: bms${bms_id}_cell_ovp
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.06.29
|
||||
# Version : 1.3.0
|
||||
# Updated : 2026.08.28
|
||||
# Version : 1.3.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -66,7 +66,6 @@ interval:
|
||||
float current = id(bms${bms_id}_current).state;
|
||||
float battery_capacity = id(bms${bms_id}_battery_capacity).state;
|
||||
float battery_soc = id(bms${bms_id}_state_of_charge).state;
|
||||
float bulk_v = id(yambms${yambms_id}_bulk_voltage).state;
|
||||
|
||||
// Voltage
|
||||
float voltage = cell_count * (min_cell_v + max_cell_v) / 2;
|
||||
@@ -76,12 +75,6 @@ interval:
|
||||
float power = (voltage * current);
|
||||
id(bms${bms_id}_power).publish_state(power);
|
||||
|
||||
// Equalizing
|
||||
bool equalizing = false;
|
||||
if (max_cell_v > bulk_v / cell_count)
|
||||
equalizing = true;
|
||||
id(bms${bms_id}_bms_equalizing).publish_state(equalizing);
|
||||
|
||||
// Capacity Remaining
|
||||
id(bms${bms_id}_capacity_remaining_ah).publish_state(battery_capacity * battery_soc / 100);
|
||||
|
||||
|
||||
Reference in new issue