Moved Auto CCL Current Taper section
This commit is contained in:
1 parent
e4b8aacc0a
commit
b7bb2e93ea
1 file changed
+16
-17
@@ -429,23 +429,6 @@ Afterwards the battery is then discharged, however `Requested Charge Current (CC
|
||||
`Auto SoC Limit` - `Auto SoC Hysteresis` = `80%` - `5%` = `75%`. Without this, the `SoC` would oscillate between
|
||||
`79%` and `80%`, stressing components unnecessary.
|
||||
|
||||
|
||||
## Inverter Heartbeat Monitoring
|
||||
|
||||

|
||||
|
||||
This feature allows you to monitor the heartbeat of your inverter (time between two ACK 0x305). This is useful for troubleshooting purposes and should not remain enabled continuously.
|
||||
|
||||
This heartbeat must be regular and depends on the selected `CAN protocol` and the behavior of the inverter. If the heartbeat is not regular this can show a problem on the inverter side or an overloaded ESP32.
|
||||
|
||||
The `Deye` inverter sends an ACK `0x305` in response to the reception of a CAN frame `0x356`. Knowing that CAN frames are sent every `100ms` and that the CAN protocol `PYLON 1.2` has 6 CAN frames, the heartbeat of the `Deye` inverter is `600ms`.
|
||||
|
||||
> [!IMPORTANT]
|
||||
> Every `2h` Deye takes more than `3s` to respond and more than `5s` at midnight.
|
||||
> This is what the `CANBUS Status` looks like when the `canbus_link_timer` is set to `3s`.
|
||||
|
||||

|
||||
|
||||
## Auto CCL Current Taper
|
||||
|
||||
Optional Auto CCL package (`yambms_auto_ccl_current_taper.yaml`).
|
||||
@@ -495,6 +478,22 @@ Notes:
|
||||
- If you taper toward near zero, you may also need a higher cut-off voltage or a longer cut-off timer to avoid an early `Cut-Off`.
|
||||
- Pair with `Charger Offset V.` when the inverter undershoots bulk.
|
||||
|
||||
## Inverter Heartbeat Monitoring
|
||||
|
||||

|
||||
|
||||
This feature allows you to monitor the heartbeat of your inverter (time between two ACK 0x305). This is useful for troubleshooting purposes and should not remain enabled continuously.
|
||||
|
||||
This heartbeat must be regular and depends on the selected `CAN protocol` and the behavior of the inverter. If the heartbeat is not regular this can show a problem on the inverter side or an overloaded ESP32.
|
||||
|
||||
The `Deye` inverter sends an ACK `0x305` in response to the reception of a CAN frame `0x356`. Knowing that CAN frames are sent every `100ms` and that the CAN protocol `PYLON 1.2` has 6 CAN frames, the heartbeat of the `Deye` inverter is `600ms`.
|
||||
|
||||
> [!IMPORTANT]
|
||||
> Every `2h` Deye takes more than `3s` to respond and more than `5s` at midnight.
|
||||
> This is what the `CANBUS Status` looks like when the `canbus_link_timer` is set to `3s`.
|
||||
|
||||

|
||||
|
||||
## Diagnostic
|
||||
|
||||
Useful information for troubleshooting.
|
||||
|
||||
Reference in new issue
Block a user