YamBMS: Inverter brand registry and RS485 entry point

Rename the inverter registry to yambms_brand_registry.yaml and add the new brands.
yambms_rs485.yaml becomes the file to include, with a rs485_protocol var that
selects PYLON or Voltronic LIB.
This commit is contained in:
Sleeper85 committed 2026-11-08 23:08:34 +01:00
1 parent 9febfa4161
commit ee12380087
13 files changed
+255 -79

No files matched your search

+16 -2
View File
@@ -110,5 +110,19 @@ The following are confirmed and known to work:
| MidNite Solar | MN15-12KW-AIO | PYLON | CAN : PYLON V1 | --- | [@goldserve](https://diysolarforum.com/members/goldserve.52541/), [@jahyde](https://diysolarforum.com/members/jahyde.7475/) |
| SRNE | HESP48120U200-H | UZE | CAN : PYLON V2 | Most PYLON-based protocols show same results. Inverter does not work in PYLON mode, UZE works. Incorrect temp reported. | [@ogremustcrush](https://diysolarforum.com/members/ogremustcrush.116979/) |
| Studer | XTM-4000 | Pylontech | CAN : PYLON V2 | DIP Switch in Xcom-CAN: 11000110 (1 to 8, ON==1). | [@kolins-cz](https://github.com/kolins-cz) |
| Schneider | XW Pro 6848 NA | Voltage Control Li-Ion | CAN : PYLON V2 | The extended 29-bit ACK is handled automatically since YamBMS 1.8.1, no option to set. | [@AGDorsum](https://diysolarforum.com/members/agdorsum.29403/), [@ngustas](https://diysolarforum.com/members/ngustas.126045/) |
| SMA | Sunny Island | --- | --- | --- | --- |
| Schneider | XW Pro 6848 NA | Voltage Control Li-Ion | CAN : PYLON V2 | The extended 29-bit ACK is handled automatically since YamBMS 1.8.0, no option to set. | [@AGDorsum](https://diysolarforum.com/members/agdorsum.29403/), [@ngustas](https://diysolarforum.com/members/ngustas.126045/) |
| SMA | Sunny Island | --- | CAN : SMA | --- | --- |
## Supported MPPT chargers
The following are confirmed and known to work:
| Brand | Model | Inverter bat. mode | CAN/RS485 protocol | Remarks | Reported by |
| --- | --- | --- | --- | --- | --- |
| Epever | IT-NC | BPRO 21 | RS485 : PYLON | --- | --- |
| Epever | ET-NC | BPRO 21 | RS485 : PYLON | --- | --- |
| Epever | TIS | BPRO 21 | RS485 : PYLON | --- | --- |
| Epever | TES | BPRO 21 | RS485 : PYLON | --- | --- |
| Epever | TEP | BPRO 21 | RS485 : PYLON | --- | --- |
| Epever | TBP | BPRO 21 | RS485 : PYLON | --- | --- |
| Epever | Tracer-AN G3 | BPRO 21 | RS485 : PYLON | --- | --- |
+18
View File
@@ -40,13 +40,31 @@ works well for you.
| Growatt | CAN L52 | CAN | PYLON V1 |
| LuxPower | Lithium 6 | CAN | LuxPower |
| MidNite Solar | PYLON | CAN | PYLON V1 |
| MPP Solar | PYL | RS485 | PYLON |
| MPP Solar | LIB | RS485 | LIB |
| Schneider | Voltage Control Li-Ion | CAN | PYLON V2 |
| SMA | - | CAN | SMA |
| Sofar | Automatic | CAN | PYLON V1 |
| Sol-Ark | Lithium 00 | CAN | PYLON V1 |
| Sol-Ark | Lithium 12 | RS485 | PYLON |
| Solis | AoBo | CAN | SMA |
| SRNE | UZE | CAN | PYLON V2 |
| Studer | Pylontech | CAN | PYLON V2 |
| Sunsynk | Lithium 00 | CAN | PYLON V1 |
| Sunsynk | Lithium 12 | RS485 | PYLON |
| Victron | CAN-bus BMS LV (500 kbit/s) | CAN | Victron |
| Voltronic | PYL | RS485 | PYLON |
| Voltronic | LIB | RS485 | LIB |
Any other brand of the list, or a listed brand on the other bus, uses `PYLON V2` on CAN by default,
and the protocol compiled on the node on RS485. Such a combination has not been validated, and the
`Note` entity says so.
On RS485 the protocol is chosen in your YAML with `rs485_protocol` (`pylon` or `voltronic`), and the
brand does not change it. `LIB` only works with `Voltronic` and `MPP Solar`: in `Automatic`, a node
compiled for `LIB` stays silent for any other brand. Rebranded Voltronic inverters must select
`Voltronic`. The protocols offered by parameter `05` depend on the inverter firmware, see its user
manual.
A few couples outside the default mapping are known to work as well, and YamBMS reports the right
battery mode for them too: `EG4` on `PYLON V1` (Lithium 2, 6000XP only) and `Solis` on `PYLON V2`
+5 -2
View File
@@ -8,7 +8,12 @@
* YamBMS 1.8.1 :
* **Breaking change** - New `Inverter brand` select and reworked `Protocol` select : selecting your inverter brand is enough, the protocol follows ; a protocol chosen explicitly still takes priority over the brand. Both selects are renamed, so their stored value is reset : **the inverter link stays inactive until you select your inverter brand**, see [release note](documents/README/changelog/Changelog_Inverter_brand_and_protocol.md)
* Removed the `YamBMS name` select : the manufacturer name sent on CAN frame `0x35E` is now derived from the protocol in use, which is what the `Automatic` mode already did ; the `GOODWE`, `SHEnergy` and `BYD` names are no longer selectable
* The RS485 baud rate is now applied at runtime with `set_baud_rate()` + `load_settings()` instead of extending the `uart` component : `uart: !extend` only works on a native ESP32 UART, so boards using a UART expander (`wk2168` on the PVbrain2) had to include an internal file to avoid it ; every board now includes the same entry point
* RS485 packages reorganised for the additional protocols to come : the file you include changes from `yambms_rs485_pylon.yaml` to `yambms_rs485.yaml`, which now takes a `rs485_protocol` var (`pylon` or `voltronic`) and includes the matching protocol implementation for you ; a node with several RS485 links on different UARTs can run a different protocol on each, one var per link ; `yambms_rs485_pylon_web_server.yaml` becomes `yambms_rs485_web_server.yaml` and must now be included alongside the entry point with its own `rs485_id`, instead of swapping one for the other, see [release note](documents/README/changelog/Changelog_Inverter_brand_and_protocol.md)
* New diagnostic entities per inverter link : `Inverter link protocol` (what the link is actually doing, e.g. `Solis - CAN SMA`), `Inverter battery mode` (how to configure the battery type on the inverter, keyed on brand *and* protocol so that forcing a protocol never displays a wrong instruction) and `Note` (what is specific to that brand and protocol)
* Renamed CAN protocol `PYLON 1.2` to `PYLON V1` and RS485 protocol `Pylontech` to `PYLON`
* Schneider XW Pro : the extended 29-bit ACK is now handled automatically and the `canbus_extended_ack` substitution is removed - both the 11-bit and the 29-bit ACK are listened to at the same time, which the CAN component supports natively
@@ -17,8 +22,6 @@
* Fixed the RS485 link staying up with `Disabled` : the proxy sensors kept their last value, so the Pylontech component went on answering the inverter with stale data and kept reporting its status as ON ; the sensors it checks are now invalidated when the protocol is off, which makes it stop answering and report the link as down
* Fixed the CAN bus not stopping when the protocol was set to `Disabled` at runtime : the frame index kept its previous value and the last frame was re-emitted every 100 ms
* Fixed the reported communication bus and protocol being overwritten when a node declares several inverter links : each link now owns its slot, and the telemetry reports every link instead of the last one
* The RS485 baud rate is now applied at runtime with `set_baud_rate()` + `load_settings()` instead of extending the `uart` component : `uart: !extend` only works on a native ESP32 UART, so boards using a UART expander (`wk2168` on the PVbrain2) had to include an internal file to avoid it ; every board now includes the same entry point
* RS485 packages reorganised internally for the additional protocols to come : `yambms_rs485_pylon.yaml` **stays the file you include**, no change there ; its selects/diagnostics/UART machinery move out to a new shared `yambms_rs485.yaml` (replacing the old internal `yambms_rs485_pylon_core.yaml`), which `yambms_rs485_pylon.yaml` includes itself so that a node with several RS485 links on different UARTs can run a different protocol on each ; `yambms_rs485_pylon_web_server.yaml` becomes `yambms_rs485_web_server.yaml` and must now be included alongside the protocol file with its own `rs485_id`, instead of swapping one for the other, see [release note](documents/README/changelog/Changelog_Inverter_brand_and_protocol.md)
* YamBMS 1.8.0 :
* Set esphome `min_version` to `2026.8.0`
@@ -6,13 +6,21 @@ The inverter link is now described by **two selects** instead of one:
| Select | Options | Default |
| --- | --- | --- |
| `Inverter brand` | `Not defined`, `Other`, then the supported brands | `Not defined` |
| `Inverter brand` | `Not defined`, `Other`, then the inverter brands | `Not defined` |
| `Protocol` | `Automatic`, `Disabled`, then the protocols of that bus | `Automatic` |
Selecting your inverter brand is enough: with `Protocol` on `Automatic`, YamBMS applies the
protocol that matches your brand. Choosing a protocol explicitly always takes priority over the
brand, so an inverter that does not follow the usual mapping can still be driven.
The brand list also covers manufacturers that are not validated yet. Those use `PYLON V2` on CAN
and the protocol compiled on the node on RS485, and the `Note` entity tells you the brand has not
been validated on that bus.
On RS485 the brand never changes the protocol, which is the `rs485_protocol` of your YAML. `LIB`
only works with `Voltronic` and `MPP Solar`: in `Automatic`, a node compiled for `LIB` stays silent
for any other brand. Rebranded Voltronic inverters must select `Voltronic`.
The old `YamBMS name` select is **removed**. The manufacturer name announced on CAN frame `0x35E`
is now derived from the protocol in use — exactly the names the `Automatic` mode already sent, and
which are known to work. The `GOODWE`, `SHEnergy` and `BYD` names are no longer selectable.
@@ -73,18 +81,24 @@ line from your YAML if you had set it.
## RS485 package files
`yambms_rs485_pylon.yaml` **stays the file you include** — no change there. Its internals are
reorganised to make room for the additional RS485 protocols to come: the `Inverter brand`/
`Protocol` selects, diagnostics and telemetry move out to a new shared file, `yambms_rs485.yaml`,
which `yambms_rs485_pylon.yaml` includes itself. Each protocol file includes
`yambms_rs485.yaml` this way round, rather than the other way, so that a node with several RS485
links on different UARTs can run a different protocol on each.
**The file you include changes**, from `yambms_rs485_pylon.yaml` to `yambms_rs485.yaml`. This
makes room for the additional RS485 protocols to come: `yambms_rs485.yaml` carries the `Inverter
brand`/`Protocol` selects, diagnostics and telemetry, and takes a new `rs485_protocol` var
(`pylon` or `voltronic`) that tells it which protocol implementation to include for you
(`yambms_rs485_pylon.yaml`, keeping the PYLON implementation only, or the new
`yambms_rs485_voltronic.yaml`). A node with several RS485 links on different UARTs can run a
different protocol on each, since each link's `vars:` names its own `rs485_protocol`.
`yambms_rs485_pylon_web_server.yaml` becomes `yambms_rs485_web_server.yaml`, and unlike before it
no longer includes the link itself: add it **alongside** `yambms_rs485_pylon.yaml` in your YAML,
with its own `vars: { rs485_id: '1' }` matching the link it decorates, instead of swapping one file
for the other.
> [!IMPORTANT]
> Point your `!include` to `yambms_rs485.yaml` and add `rs485_protocol: 'pylon'` to its `vars:`.
> This relies on substitutions in an `!include` filename, added in ESPHome 2026.4.0
> ([esphome#12213](https://github.com/esphome/esphome/pull/12213)) — already covered by this
> project's `min_version: 2026.10.0`, so no extra requirement for you.
`rs485_uart_baud_rate` keeps the same meaning but is now applied at runtime instead of extending
the `uart` component, and defaults to `9600`. Boards using a UART expander — the `wk2168` of the
PVbrain2 — no longer need a separate include: every board now uses the same entry point.
`yambms_rs485_pylon_web_server.yaml` becomes `yambms_rs485_web_server.yaml`. It includes the link
itself, so use it **instead of** `yambms_rs485.yaml`, not alongside it, with the same `vars:`.
`rs485_uart_baud_rate` keeps the same meaning and defaults to `9600`. The link now declares its
UART itself from `rs485_uart_id`, so remove the `board_options_itf_uart_*.yaml` include of that UART
from your YAML. Boards using a UART expander — the `wk2168` of the PVbrain2 — no longer need a
separate include: every board now uses the same entry point.
+35 -2
View File
@@ -254,7 +254,7 @@ may not have happened yet, not a scheduling order.
## The inverter protocol is resolved once, never in the loop
**Files:** `packages/yambms/yambms_inverter_registry.yaml`, `packages/yambms/yambms_canbus.yaml`,
**Files:** `packages/yambms/yambms_brand_registry.yaml`, `packages/yambms/yambms_canbus.yaml`,
`packages/yambms/yambms_rs485.yaml`
The protocol actually applied on a link is not readable from a single select. It is the result of
@@ -318,6 +318,39 @@ of the interval publishes those `NaN` once per transition, guarded by
Only those eight sensors matter — the ones read by `update_state_from_sensors_()`. Invalidating the
others would be harmless but pointless, and would hide which ones the contract actually depends on.
### On RS485 the protocol is compiled, the brand only gates it
**Files:** `packages/yambms/yambms_rs485.yaml`, `packages/yambms/yambms_rs485_pylon.yaml`,
`packages/yambms/yambms_rs485_voltronic.yaml`
`rs485_protocol` picks the implementation at compile time, and each implementation declares what
it is in `rs485${rs485_id}_compiled_protocol`. In `Automatic` the resolution script applies that
value and never derives a protocol from the brand: a node can only speak what was compiled into
it, and resolving anything else made the diagnostics describe a protocol that was not running.
Voltronic and MPP Solar are the reason this cannot be a brand mapping. On recent firmwares,
parameter `05` offers both `PYL` and `LIB` on RS485, so either implementation is a valid choice
for the same inverter and the brand says nothing about which one was compiled.
`LIB` is the one exception. It is a Voltronic protocol and no other brand can use it, so in
`Automatic` a node compiled for `LIB` stays silent for any other brand, and `Note` says why.
Forcing `LIB` is still possible, because an explicit protocol always takes priority over the
brand. Rebranded inverters are expected to select `Voltronic`. MPP Solar is not a rebrand, which
is why it has its own entry.
### Turning the LIB link off means moving its Modbus address
**File:** `packages/yambms/yambms_rs485_voltronic.yaml`
`modbus_server` has no off switch, and returning nothing from a `read_lambda` only turns the reply
into an exception frame, so the inverter still gets an answer on a link that should be silent.
`ModbusServerHub::find_device_()` matches the address on every request, so moving the server to
address `248` makes the hub drop the request instead. The 100 ms interval moves it back to `1`
only while `rs485${rs485_id}_active_protocol` is `LIB`.
Do not replace this with reported charge and discharge limits of zero: the inverter would still
see a battery, on a link the user believes is off.
### `Disabled` unregisters the link instead of faulting it
**File:** `packages/base/device_base_fault_registry.yaml`
@@ -339,7 +372,7 @@ Without the second one the link timer would re-raise the fault a few seconds lat
A link left at `Automatic` with no brand selected is deliberately **not** unregistered — it faults.
That is the signal telling the user the node was never configured, which is the whole point of the
1.8.1 breaking change.
1.8.0 breaking change.
### Both ACK triggers are registered
+2 -2
View File
@@ -51,12 +51,12 @@ All three follow the same layered scheme, per brand and protocol:
### `yambms/`
The central engine. `yambms.yaml` aggregates `yambms_inverter_registry.yaml`,
The central engine. `yambms.yaml` aggregates `yambms_brand_registry.yaml`,
`yambms_core.yaml`, the `yambms_auto_*.yaml` functions (CVL / CCL / DCL / Float / EOC /
temperature / SoC limit) and `yambms_service.yaml`, then `yambms_canbus*.yaml` or
`yambms_rs485*.yaml` for the link to the inverter.
`yambms_inverter_registry.yaml` holds the protocol dictionary (`YB_PROTO_*`), the brand to
`yambms_brand_registry.yaml` holds the protocol dictionary (`YB_PROTO_*`), the brand to
protocol mapping and the per-couple battery mode and note. Both inverter buses read it.
On the RS485 side, `yambms_rs485.yaml` is the entry point — selects, diagnostics, telemetry
+4 -4
View File
@@ -1,5 +1,5 @@
# Updated : 2026.09.02
# Version : 1.1.7
# Updated : 2026.11.05
# Version : 1.1.8
# GitHub : https://github.com/Sleeper85/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -18,8 +18,8 @@
# along with this program. If not, see <http://www.gnu.org/licenses/gpl.html>.
packages:
# Inverter registry (protocol dictionary, brand mapping, battery modes)
yambms_inverter_registry: !include yambms_inverter_registry.yaml
# Brand registry (protocol dictionary, brand mapping, battery modes)
yambms_brand_registry: !include yambms_brand_registry.yaml
# YamBMS Core
yambms_core: !include yambms_core.yaml
# YamBMS Auto Functions
@@ -1,5 +1,5 @@
# Updated : 2026.09.04
# Version : 1.1.1
# Updated : 2026.11.05
# Version : 1.1.2
# GitHub : https://github.com/Sleeper85/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -18,7 +18,7 @@
# along with this program. If not, see <http://www.gnu.org/licenses/gpl.html>.
# +----------------------------------------------------------------------------+
# | Inverter registry |
# | Brand registry |
# | |
# | Shared by the CAN and the RS485 inverter links. Holds: |
# | - the protocol dictionary (YB_PROTO_*) |
@@ -31,6 +31,10 @@
# | user can always override it with the `Protocol` select. Only the battery |
# | mode is asserted, and only for couples that were actually confirmed by a |
# | user; anything else returns "See inverter manual". |
# | |
# | A brand with no mapping gets PYLON V2 on CAN and the compiled protocol on |
# | RS485, and its note says it was not validated. `Not defined` and `Other` |
# | are not brands: they resolve to nothing and the user has to choose. |
# +----------------------------------------------------------------------------+
substitutions:
@@ -76,20 +80,20 @@ globals:
if (brand == "Schneider") return ${YB_PROTO_CAN_PYLON_V2};
if (brand == "SMA") return ${YB_PROTO_CAN_SMA};
if (brand == "Sofar") return ${YB_PROTO_CAN_PYLON_V1};
if (brand == "Sol-Ark") return ${YB_PROTO_CAN_PYLON_V1};
if (brand == "Solis") return ${YB_PROTO_CAN_SMA};
if (brand == "SRNE") return ${YB_PROTO_CAN_PYLON_V2};
if (brand == "Studer") return ${YB_PROTO_CAN_PYLON_V2};
if (brand == "Sunsynk") return ${YB_PROTO_CAN_PYLON_V1};
if (brand == "Victron") return ${YB_PROTO_CAN_VICTRON};
return ${YB_PROTO_NONE};
// Any other brand was not validated on CAN: the note reports it.
return ${YB_PROTO_CAN_PYLON_V2};
}
// RS485: every known brand maps to PYLON, except the Voltronic-derived
// family (Axpert, InfiniSolar, MPP Solar) whose "LIB" battery type is a
// distinct, unrelated protocol - see yambms_rs485_voltronic.yaml.
if (bus == "RS485") {
if (brand == "MPP Solar" || brand == "Voltronic") return ${YB_PROTO_RS485_VOLTRONIC_LIB};
return ${YB_PROTO_RS485_PYLON};
}
// RS485: the protocol is chosen at compile time (`rs485_protocol`), so the
// link only needs to know that a brand was selected. The script in
// yambms_rs485.yaml replaces this value with the compiled protocol.
if (bus == "RS485") return ${YB_PROTO_RS485_PYLON};
return ${YB_PROTO_NONE};
}
@@ -140,14 +144,20 @@ globals:
if (brand == "Growatt" && proto == ${YB_PROTO_CAN_PYLON_V1}) return "CAN L52";
if (brand == "LuxPower" && proto == ${YB_PROTO_CAN_LUXPOWER}) return "Lithium 6";
if (brand == "MidNite Solar" && proto == ${YB_PROTO_CAN_PYLON_V1}) return "PYLON";
if (brand == "MPP Solar" && proto == ${YB_PROTO_RS485_PYLON}) return "PYL";
if (brand == "MPP Solar" && proto == ${YB_PROTO_RS485_VOLTRONIC_LIB}) return "LIB";
if (brand == "Schneider" && proto == ${YB_PROTO_CAN_PYLON_V2}) return "Voltage Control Li-Ion";
if (brand == "Sofar" && proto == ${YB_PROTO_CAN_PYLON_V1}) return "Automatic";
if (brand == "Sol-Ark" && proto == ${YB_PROTO_CAN_PYLON_V1}) return "Lithium 00";
if (brand == "Sol-Ark" && proto == ${YB_PROTO_RS485_PYLON}) return "Lithium 12";
if (brand == "Solis" && proto == ${YB_PROTO_CAN_SMA}) return "AoBo";
if (brand == "Solis" && proto == ${YB_PROTO_CAN_PYLON_V2}) return "Pylon LV";
if (brand == "SRNE" && proto == ${YB_PROTO_CAN_PYLON_V2}) return "UZE";
if (brand == "Studer" && proto == ${YB_PROTO_CAN_PYLON_V2}) return "Pylontech";
if (brand == "Sunsynk" && proto == ${YB_PROTO_CAN_PYLON_V1}) return "Lithium 00";
if (brand == "Sunsynk" && proto == ${YB_PROTO_RS485_PYLON}) return "Lithium 12";
if (brand == "Victron" && proto == ${YB_PROTO_CAN_VICTRON}) return "CAN-bus BMS LV (500 kbit/s)";
if (brand == "Voltronic" && proto == ${YB_PROTO_RS485_PYLON}) return "PYL";
if (brand == "Voltronic" && proto == ${YB_PROTO_RS485_VOLTRONIC_LIB}) return "LIB";
return "See inverter manual";
@@ -165,15 +175,36 @@ globals:
[](std::string brand, int proto) -> std::string {
if (brand == "EG4" && proto == ${YB_PROTO_CAN_PYLON_V1}) return "6000XP only.";
if (brand == "Epever" && proto == ${YB_PROTO_RS485_PYLON}) return "Verified on ET-NC and IT-NC inverter-chargers. Other Epever models may only support the Epever BMS Link protocol. BPRO 21 defaults to 115200 baud on ET/IT chargers, not the 9600 default - set rs485_uart_baud_rate accordingly.";
if (brand == "Epever") return "Unverified: Epever inverter-chargers are documented on RS485 PYLON.";
if (brand == "Epever" && proto == ${YB_PROTO_RS485_PYLON}) return "Set protocol ID 21 (BPRO 21). A direct RS485 link works on most models, UPower-Hi requires the external BMS-Link. BPRO 21 defaults to 115200 baud not the 9600 default - set rs485_uart_baud_rate accordingly.";
if (brand == "Epever") return "Unverified: Epever is documented on RS485 PYLON, no CAN support is known.";
if ((brand == "MPP Solar" || brand == "Voltronic") && proto == ${YB_PROTO_RS485_VOLTRONIC_LIB})
return "Unverified: per Voltronic's own documentation, only the charge voltage limit is applied by the inverter firmware - discharge voltage and both current limits are documented as unused.";
if ((brand == "MPP Solar" || brand == "Voltronic") && proto == ${YB_PROTO_RS485_PYLON})
return "See user manual: set parameter 05 to PYL. For LIB, set rs485_protocol to 'voltronic'.";
if (brand == "Schneider" && proto == ${YB_PROTO_CAN_PYLON_V2}) return "The extended 29-bit ACK is handled automatically.";
if (brand == "Sofar" && proto == ${YB_PROTO_CAN_PYLON_V1}) return "A 120 Ohm resistor may be required on the Sofar side.";
if (brand == "Solis" && proto == ${YB_PROTO_CAN_PYLON_V2}) return "A 3.3V CAN transceiver (SN65HVD230) is required.";
if (brand == "SRNE" && proto == ${YB_PROTO_CAN_PYLON_V2}) return "The inverter reports an incorrect battery temperature.";
if (brand == "Studer" && proto == ${YB_PROTO_CAN_PYLON_V2}) return "Xcom-CAN DIP switches: 11000110 (1 to 8, ON = 1).";
// Not brands: nothing to validate, even with a protocol forced by hand.
if (brand == "Not defined" || brand == "Other") return "";
// LIB is a Voltronic protocol: the two brands it applies to returned above.
if (proto == ${YB_PROTO_RS485_VOLTRONIC_LIB})
return "LIB only works with Voltronic and MPP Solar. Rebranded inverters must select Voltronic, otherwise set rs485_protocol to 'pylon'.";
// Brands confirmed on each bus. The leading digit of a protocol names its
// bus, so this also covers a protocol forced by hand.
bool can_validated = brand == "Deye" || brand == "EG4" || brand == "GoodWe" ||
brand == "Growatt" || brand == "LuxPower" || brand == "MidNite Solar" ||
brand == "Schneider" || brand == "SMA" || brand == "Sofar" ||
brand == "Sol-Ark" || brand == "Solis" || brand == "SRNE" ||
brand == "Studer" || brand == "Sunsynk" || brand == "Victron";
bool rs485_validated = brand == "Deye" || brand == "Epever" || brand == "Sol-Ark" || brand == "Sunsynk";
if (proto / 100 == 1 && !can_validated) return "Unverified: this brand has not been validated on CAN bus yet.";
if (proto / 100 == 2 && !rs485_validated) return "Unverified: this brand has not been validated on RS485 yet.";
return "";
}
+12 -2
View File
@@ -1,5 +1,5 @@
# Updated : 2026.09.04
# Version : 2.7.1
# Updated : 2026.11.05
# Version : 2.7.2
# GitHub : https://github.com/Sleeper85/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -107,20 +107,30 @@ select:
options:
- "Not defined"
- "Other"
- "Afore"
- "Deye"
- "EG4"
- "Epever"
- "Felicity Solar"
- "FoxESS"
- "GoodWe"
- "Growatt"
- "Kstar"
- "LuxPower"
- "Megarevo"
- "MidNite Solar"
- "MPP Solar"
- "Must"
- "Phocos"
- "Renogy"
- "Schneider"
- "SMA"
- "Sofar"
- "Sol-Ark"
- "Solis"
- "SRNE"
- "Studer"
- "Sunsynk"
- "Victron"
- "Voltronic"
restore_value: true
+42 -12
View File
@@ -1,5 +1,5 @@
# Updated : 2026.09.04
# Version : 1.1.1
# Updated : 2026.11.05
# Version : 1.1.2
# GitHub : https://github.com/Sleeper85/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -20,15 +20,19 @@
# +----------------------------------------------------------------------------+
# | RS485 inverter link |
# | |
# | Shared machinery for an RS485 link: the `Inverter brand` and `Protocol` |
# | selects, the diagnostics and the telemetry slot. Not the file you include |
# | - you never `!include` this one directly. Each protocol implementation |
# | (yambms_rs485_pylon.yaml, yambms_rs485_voltronic.yaml) includes THIS file, |
# | not the other way around, so that a node with several RS485 links on |
# | several UARTs can run a different protocol on each: including this file |
# | directly would hardcode one protocol for every link that does so. |
# | Entry point of the RS485 link: it carries the `Inverter brand` and |
# | `Protocol` selects, the diagnostics and the telemetry slot, then includes |
# | the protocol implementation named by the `rs485_protocol` substitution |
# | ('pylon' or 'voltronic') - requires ESPHome >= 2026.4.0 for substitutions |
# | in an `!include` filename (esphome#12213), already covered by the |
# | project's min_version. Each RS485 link passes its own `rs485_protocol` in |
# | its `vars:`, so a node with several links on several UARTs can run a |
# | different protocol on each. |
# +----------------------------------------------------------------------------+
packages:
rs485_protocol: !include yambms_rs485_${rs485_protocol}.yaml
substitutions:
# The ID of the LED on your board used for this component
rs485_status_led_id: "virtual_status_light"
@@ -113,20 +117,30 @@ select:
options:
- "Not defined"
- "Other"
- "Afore"
- "Deye"
- "EG4"
- "Epever"
- "Felicity Solar"
- "FoxESS"
- "GoodWe"
- "Growatt"
- "Kstar"
- "LuxPower"
- "Megarevo"
- "MidNite Solar"
- "MPP Solar"
- "Must"
- "Phocos"
- "Renogy"
- "Schneider"
- "SMA"
- "Sofar"
- "Sol-Ark"
- "Solis"
- "SRNE"
- "Studer"
- "Sunsynk"
- "Victron"
- "Voltronic"
restore_value: true
@@ -226,10 +240,20 @@ script:
std::string choice = id(rs485${rs485_id}_protocol).current_option();
std::string source;
int proto;
bool lib_refused = false;
// An explicit protocol always takes priority over the brand
if (choice == "Automatic") {
proto = id(global_inverter_default_protocol)(brand, "RS485");
// The protocol is chosen at compile time: the brand only decides
// whether this link may run it.
int compiled = id(rs485${rs485_id}_compiled_protocol);
bool brand_defined = id(global_inverter_default_protocol)(brand, "RS485") != ${YB_PROTO_NONE};
proto = brand_defined ? compiled : ${YB_PROTO_NONE};
// LIB is a Voltronic protocol: answering any other brand is pointless
if (proto == ${YB_PROTO_RS485_VOLTRONIC_LIB} && brand != "MPP Solar" && brand != "Voltronic") {
proto = ${YB_PROTO_NONE};
lib_refused = true;
}
source = "auto";
} else {
source = "manual";
@@ -244,14 +268,20 @@ script:
std::string label = id(global_inverter_protocol_label)(proto);
// --- Diagnostics ---
if (proto == ${YB_PROTO_NONE}) {
if (lib_refused) {
id(rs485${rs485_id}_inverter_link_protocol).publish_state(brand + " - RS485 LIB not applicable");
ESP_LOGW("rs485", "LIB does not apply to %s: nothing is sent on the RS485 bus", brand.c_str());
} else if (proto == ${YB_PROTO_NONE}) {
id(rs485${rs485_id}_inverter_link_protocol).publish_state("Inverter RS485 bus not defined");
ESP_LOGW("rs485", "No inverter brand selected and no protocol forced: nothing is sent on the RS485 bus");
} else {
id(rs485${rs485_id}_inverter_link_protocol).publish_state(brand + " - RS485 " + label);
}
if (proto == ${YB_PROTO_NONE} || proto == ${YB_PROTO_DISABLED}) {
if (lib_refused) {
id(rs485${rs485_id}_inverter_battery_mode).publish_state("");
id(rs485${rs485_id}_note).publish_state(id(global_inverter_note)(brand, ${YB_PROTO_RS485_VOLTRONIC_LIB}));
} else if (proto == ${YB_PROTO_NONE} || proto == ${YB_PROTO_DISABLED}) {
id(rs485${rs485_id}_inverter_battery_mode).publish_state("");
id(rs485${rs485_id}_note).publish_state("");
} else {
+12 -11
View File
@@ -1,5 +1,5 @@
# Updated : 2026.09.04
# Version : 1.5.1
# Updated : 2026.11.05
# Version : 1.5.2
# GitHub : https://github.com/fahmula/esphome-pylontech-rs485
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -17,15 +17,11 @@
# You should have received a copy of the GNU General Public License
# along with this program. If not, see <http://www.gnu.org/licenses/gpl.html>.
# This is the file you include for a PYLON RS485 link: it pulls in the shared
# selects/diagnostics/telemetry machinery from `yambms_rs485.yaml` and adds
# the PYLON protocol itself. Included this way round (rather than the other
# way, as before 1.8.1) so that a node with several RS485 links on several
# UARTs can run PYLON on one and Voltronic LIB on another - see
# yambms_rs485_voltronic.yaml for that alternative entry point.
packages:
rs485_entry: !include yambms_rs485.yaml
# PYLON protocol implementation. Not the file you include - include
# `yambms_rs485.yaml` instead, with `rs485_protocol: 'pylon'` in its `vars:`;
# it includes this file for you (`!include yambms_rs485_${rs485_protocol}.yaml`),
# so that a node with several RS485 links on several UARTs can run PYLON on
# one and Voltronic LIB on another, each naming its own protocol.
external_components:
- source: github://fahmula/esphome-pylontech-rs485@main
@@ -39,6 +35,11 @@ select:
- "PYLON"
globals:
# Protocol this file implements, read by the resolution script in yambms_rs485.yaml
- id: rs485${rs485_id}_compiled_protocol
type: int
restore_value: no
initial_value: "${YB_PROTO_RS485_PYLON}"
# True while the proxy sensors carry data the component may serve to the
# inverter. Turning the protocol off does not clear them by itself, so they
# have to be invalidated explicitly - see the interval below.
+32 -13
View File
@@ -1,5 +1,5 @@
# Updated : 2026.09.04
# Version : 1.1.0
# Updated : 2026.11.05
# Version : 1.1.1
# GitHub : https://github.com/Sleeper85/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -17,13 +17,12 @@
# You should have received a copy of the GNU General Public License
# along with this program. If not, see <http://www.gnu.org/licenses/gpl.html>.
# This is the file you include for a Voltronic LIB RS485 link: it pulls in
# the shared selects/diagnostics/telemetry machinery from `yambms_rs485.yaml`
# and adds the Voltronic "LIb" protocol itself - see documents/PRIVATE/
# Voltronic/Voltronic Inverter and BMS 485 communication protocol
# 20201202.docx (Voltronic Power, also referenced by Epever as PRO=26, same
# authors Ellis/Lory/Jenny). Use yambms_rs485_pylon.yaml instead for PYLON -
# never include both on the same UART, see the warning below.
# Voltronic "LIb" protocol implementation - see documents/PRIVATE/Voltronic/
# Voltronic Inverter and BMS 485 communication protocol 20201202.docx
# (Voltronic Power, also referenced by Epever as PRO=26, same authors
# Ellis/Lory/Jenny). Not the file you include - include `yambms_rs485.yaml`
# instead, with `rs485_protocol: 'voltronic'` in its `vars:`; it includes
# this file for you (`!include yambms_rs485_${rs485_protocol}.yaml`).
#
# Unlike Pylontech, this is plain Modbus RTU (function 0x03, 9600 8N1) so it
# is implemented with ESPHome's native `modbus_server:` - no external
@@ -45,9 +44,6 @@
# own locally configured charge curve regardless of what is sent there.
# - Not verified on real hardware yet.
packages:
rs485_entry: !include yambms_rs485.yaml
select:
# Adds the option this file implements to the base Automatic/Disabled list
# declared in yambms_rs485.yaml - see the comment there.
@@ -56,6 +52,11 @@ select:
- "LIB"
globals:
# Protocol this file implements, read by the resolution script in yambms_rs485.yaml
- id: rs485${rs485_id}_compiled_protocol
type: int
restore_value: no
initial_value: "${YB_PROTO_RS485_VOLTRONIC_LIB}"
# Set by the read_lambda of address 48 (the first register of the
# aggregated-data block, always read by a normal polling cycle), cleared by
# the interval below. Unlike pylontech_rs485's own update_timeout, nothing
@@ -73,6 +74,23 @@ interval:
bool polled = id(rs485${rs485_id}_voltronic_polled);
id(rs485${rs485_id}_voltronic_polled) = false;
id(rs485${rs485_id}_status).publish_state(polled);
# modbus_server has no off switch: it answers whatever is asked of its address.
# Moving it to 248, a reserved address no inverter polls, makes the hub ignore
# every request, which is the only way to keep this link truly silent.
- interval: 100ms
then:
- lambda: |-
bool active = id(rs485${rs485_id}_active_protocol) == ${YB_PROTO_RS485_VOLTRONIC_LIB};
// Mirror RS485 status into inverter_com_status. Turning the link off clears
// it once per transition, so a CAN link on the same node keeps owning it.
if (active) {
if (id(rs485${rs485_id}_status).has_state()) id(inverter_com_status).publish_state(id(rs485${rs485_id}_status).state);
} else if (id(rs485${rs485_id}_modbus_server).get_address() != 248) {
id(inverter_com_status).publish_state(false);
}
id(rs485${rs485_id}_modbus_server).set_address(active ? 1 : 248);
modbus:
- uart_id: ${rs485_uart_id}
@@ -80,7 +98,8 @@ modbus:
role: server
modbus_server:
- modbus_id: modbus_rs485_${rs485_id}
- id: rs485${rs485_id}_modbus_server
modbus_id: modbus_rs485_${rs485_id}
address: 1
registers:
# +--------------------------------------------------------------+
+5 -2
View File
@@ -1,5 +1,5 @@
# Updated : 2026.09.04
# Version : 1.1.4
# Updated : 2026.11.05
# Version : 1.1.5
# GitHub : https://github.com/Sleeper85/esphome-yambms
# YamBMS ( Yet another multi-BMS Merging Solution )
@@ -17,6 +17,9 @@
# You should have received a copy of the GNU General Public License
# along with this program. If not, see <http://www.gnu.org/licenses/gpl.html>.
packages:
rs485: !include yambms_rs485.yaml
select:
# YamBMS - Inverter Communication Protocol