yambms_canbus.yaml and the Deye top packages now import their node from
canbus_platform (esp32_can, mcp2515 or external). canbus_bitrate replaces
esp32_canbus_bitrate and mcp2515_canbus_bitrate. Breaking change.
Each package now imports its UART from its *_uart_id var and keeps its own baud
rate key. WK2168 channels work the same way, uart_flow_control_pin replaces the
flow control include, and min_version moves to 2026.10.0. Breaking change.
Rename the inverter registry to yambms_brand_registry.yaml and add the new brands.
yambms_rs485.yaml becomes the file to include, with a rs485_protocol var that
selects PYLON or Voltronic LIB.
BREAKING CHANGE: both inverter link selects are renamed, so their stored value is
reset. The link stays inactive until an inverter brand is selected. See
documents/README/changelog/Changelog_Inverter_brand_and_protocol.md
New `Inverter brand` select (16 brands) and reworked `Protocol` select, now
defaulting to `Automatic`. Selecting the brand is enough, the protocol follows;
an explicit protocol still takes priority over the brand.
The protocol is resolved once, at boot and on every select change, into
`canbus${canbus_id}_active_protocol` / `rs485${rs485_id}_active_protocol`.
Everything else reads that integer instead of dispatching on `active_index()`,
where `== 5` meant LuxPower purely by convention of the option order.
New shared `yambms_inverter_registry.yaml`: protocol dictionary (`YB_PROTO_*`),
brand to protocol mapping, and the battery mode and note of each couple.
Removed the `YamBMS name` select: the manufacturer name sent on CAN frame 0x35E
now derives from the protocol in use, which is what `Automatic` already did.
Removed the `canbus_extended_ack` substitution: both the 11-bit and the 29-bit
ACK triggers are registered, so the Schneider XW Pro needs no configuration.
Renamed CAN `PYLON 1.2` to `PYLON V1` and RS485 `Pylontech` to `PYLON`.
New per-link diagnostics `Inverter link protocol`, `Inverter battery mode` and
`Note`, with a markdown card in the dashboards, alongside a system fault card.
Telemetry: `comm_bus` / `comm_protocol` replaced by `inverter_brand`,
`inverter_bus`, `inverter_protocol` and `inverter_protocol_source`, one slot per
declared link instead of a single value overwritten by the last one.
RS485 packages split: `yambms_rs485.yaml` is the entry point carrying the selects,
`yambms_rs485_pylon.yaml` the protocol implementation. The baud rate is applied
with `set_baud_rate()` + `load_settings()` instead of extending the uart
component, so boards using a UART expander no longer need their own include.
Fixes:
- the CAN bus kept re-emitting the last frame every 100 ms when the protocol was
set to `Disabled` at runtime
- the RS485 link kept answering the inverter with stale data on `Disabled`, the
proxy sensors it reads are now invalidated
- a `Disabled` link no longer lights the fault LED, it is unregistered from the
fault registry instead of being reported as failing
- the reported bus and protocol were overwritten when a node declares several
inverter links
- changing the protocol restarts the CAN frames immediately instead of waiting up
to 30 s for the next retry tick
- update and telemetry are now gated independently by substitution;
var_service and its Update service switch are removed
- the uptime text sensor is published by its source instead of polling
it, which fixes the 24855d readings that reached the telemetry, and
the raw seconds are now sent instead of the formatted string
- the MAC address is replaced by a salted SHA-256, derived identically
server side so no pairing window is needed
The installed total was accumulated once per BMS per boot, latched by
bms<id>_combined_once, so a BMS reconfigured with a different capacity
kept contributing its boot value until the next reboot.
Each BMS now remembers the last capacity it contributed in
bms<id>_installed_capacity and applies only the difference to the total.
- the update runs in the can_be_combined branch, so an offline BMS simply
stops updating its contribution, which stays in the total : the installed
capacity still never shrinks on an uncombine, as before
- a BMS coming back with a different capacity is applied as a delta, with
no double counting
- combined_once had no other reader and is removed
The total is deliberately not turned into a per-round accumulator reset in
the Global vars reset block like the other totals : its sensor is polled
independently of STEP 2 and its state is written straight into CAN frame
0x379 with no has_state() guard, so a transient zero would announce 0 Ah of
installed capacity to the inverter. See Design_decisions.md.
http_request runs on the loop task, which has a 4s budget before the
5s task WDT panics. A dropped connect() blocks for 4.5s (the ESPHome
default timeout) and a filtered port 53 blocks for a fixed 7s, which
timeout does not cover.
- timeout 3s and watchdog_timeout 60s cover the two blocking paths
- a failure counter stops the service after 3 network-level failures,
instead of freezing the loop 14s every 6h forever
- the POST is now skipped when the GET failed
Reproduced and measured on OPNsense.
See Design_decisions.md.