Docs: Explain the 0 A limit in the combiner

Document why the combiner accepts 0 A as a valid charge and discharge limit.
This commit is contained in:
Sleeper85 committed 2026-11-08 23:08:34 +01:00
1 parent ee12380087
commit 5c171aea14
2 files changed
+6 -4

No files matched your search

+5 -3
View File
@@ -42,9 +42,11 @@ The condition in `bms_combine.yaml` checks every sensor the combiner will read.
purpose: a single missing or `NaN` value entering the totals corrupts the aggregate that drives
the inverter. Do not shorten it to a few representative checks.
Note that the checks are not uniform. Most use `has_state()`, but `total_voltage`,
`battery_capacity`, `max_charge_current` and `max_discharge_current` use `> 0` — a BMS reporting
zero for those is treated as not ready rather than as a valid reading.
Note that the checks are not uniform. Most use `has_state()`, but `total_voltage` and
`battery_capacity` use `> 0` — a BMS reporting zero for those is treated as not ready rather than
as a valid reading. `max_charge_current` and `max_discharge_current` use `>= 0`: `0 A` is a valid
limit that a BMS can announce, and it must not take that BMS out of the combination. A `NaN` still
fails the comparison, so a limit that was never received keeps the BMS uncombined.
### Combined by contribution, combined continuously, uncombined
+1 -1
View File
@@ -1,4 +1,4 @@
# Updated : 2026.09.02
# Updated : 2026.11.05
# Version : 1.8.1
# GitHub : https://github.com/Sleeper85/esphome-yambms