With Automatic SoC Limit Mode set to Float and Rebulk SoC >= Automatic SoC Limit it won't work as expected because Rebulk SoC takes priority and switches to Bulk. This was reported in the forum: https://diysolarforum.com/threads/yambms-jk-bms-can-with-new-cut-off-charging-logic-open-source.79325/page-294#post-1848293
When Rebulk SoC >= Automatic SoC Limit and Automatic SoC Limit is enabled, set Rebulk SoC to Automatic SoC Limit - Auto SoC Limit Hysteresis - 5%. For example: Rebulk SoC = 85%, Automatic SoC Limit = 80%, Auto SoC Limit Hysteresis = 5% would result in Rebulk SoC = 70%.
This adds `Rebulk Days` which specify the number of days since last full charge to enter `Bulk` again. It works like `Rebulk SoC` or `Rebulk V.` and can be disabled by setting it to 0 days.
- Disable when `Force Bulk` is active
- Disable when charging status is not `Bulk` or `Float`
- Add additional status messages to make clear what happens
- Adjusted light control logic to handle RGB settings and state changes more effectively.
- Introduced a new substitution `board_has_rgb` to indicate RGB functionality availability.
- Removed the deprecated `board_options_rgb_led_status.yaml` file.
- Enhanced CAN bus and RS485 configurations to include LED control based on device status.
- Updated T-Connect and YamBMS behaviour documentation
The `bms_ids` variable allows to provide an array of BMS IDs that are connected to this shunt.
If one or more BMS from this array are offline, the shunt is not used anymore (Combine = Disabled). This avoids returning a wrong SOC when not all batteries are online/available anymore.
If the BMS goes online again, the shunt is then used again.
This variable is optional. If not provided, the shunt work independently from the BMS online status.
Examples:
```
bms_ids: '{1}'
bms_ids: '{1, 2}'
bms_ids: '{4, 5, 6}'
```
* Update BMS min/max temperature filters to filter out noise
* Add filters for Basen temperature sensors
- Basen temperature sensors only have full integer resolution. Add additional filters to reduce noise.
* Update filter for min/max temperature
- Change filters for min/max temperature to reduce noise introduced by changes in the lowest bit (0.1°C). Otherwise this noise will be forwarded by auto temp based current to the requrested charge/discharge current and therefore to the inverter.
* CCL, DCL and Auto Temp Current Control
* Added following:
- Update temperature based current derating, now uses calibrate_linear
- Revised CCL and DCL to correctly apply derating when multiple functions are enabled
- Added diagnostic sensor showing derating reason
* Changed referenced sensor for Auto DCP temperature derating
* Updated Auto Temp logic
* Add documentation, rename package