Files

13 KiB

YamBMS - JK-PB Inverter BMS

Badge License: GPLv3 Badge Version GitHub stars GitHub forks GitHub watchers

Warning

There is a known bug with the latest version of JK firmware >= V19.10. Using DIP switch addresses 1 to 15 does not reliably guarantee that the UART2 (RS485-2) port protocol will be automatically configured to 001 - JK BMS RS485 Modbus V1.0, which allows YamBMS to access BMS informations. YamBMS users have confirmed that it is possible to resolve this issue by performing an Erase History Data from the JK app on a smartphone.

Important

The most important thing for proper functioning of YamBMS is that the voltage of your BMS is well calibrated. YamBMS logic is based on the min_cell_voltage and max_cell_voltage voltages of your BMS. If you use YamBMS, the internal charging logic of the JK-PB BMS will not be used.

JK-PB BMS overview

Image
Image
Image

JK-PB BMS protocol

The datas from this BMS can be retrieved from the RS485-1 (UART1) or RS485-2 (UART2) network using the component JK_RS485 originally developed by @txubelaxu.

The BMS DIP switches must be set from 1 to 15 (server mode) and connected to each other using the RS485-2 network available on the two ports at the right ends. YamBMS also connects to one of these two ports.

UART2 configuration

Note

The protocol of the UART2 port is not selectable from the JK application. It is automatically set based on the address (DIP switch) of the BMS.

In the last software version only two protocols are available on the RS485-2 (UART2) ports:

  • 001 - JK BMS RS485 Modbus V1.0 (DIP switch 1 to 15)
  • 015 - UART Protocol 015 (DIP switch 0)

UART1 configuration

The following protocols are supported on the RS485-1 (UART1) port:

(italic options ane not settable)

  • 000 - 4G-GPS Remote module Common protocol V4.2
  • 001 - JK BMS RS485 Modbus V1.0
  • 002 - NIU U SERIES
  • 003 - China tower shared battery cabinet V1.1
  • 004 - PACE_RS485_Modbus_V1.3
  • 005 - PYLON_low_voltage_Protocol_RS485_V3.5
  • 006 - Growatt_BMS_RS485_Protocol_1xSxxP_ESS_Rev2.01
  • 007 - Voltronic_Inverter_and_BMS_485_communication_protocol_20200...
  • 008 - China tower shared battery cabinet V2.0
  • 009 - WOW_RS485_Modbus_V1.3
  • 010 - JK BMS LCD Protocol V2.0
  • 011 - UART1 User customization
  • 012 - UART2 User customization
  • 013 - (9600)JK BMS RS485 Modbus V1.0
  • 014 - (9600)PYLON_low_voltage_Protocol_RS485_V3.5
  • 015 - UART Protocol 015

CAN port configuration

The following CAN protocols are supported on the CAN port:

(italic options ane not settable)

  • 000 - JK BMS CAN Protocol (250K) V2.0
  • 001 - Deye Low-voltage hybrid inverter CAN communication protocol V1.0
  • 002 - PYLON-Low-voltage-V1.2
  • 003 - Growatt BMS CAN-Bus-protocol-low-voltage_Rev_05
  • 004 - Victron_CANbus_BMS_protocol_20170717
  • 005 - MEGAREVO_Hybird_BMSCAN_Protocol_V1.0
  • 006 - JK BMS CAN Protocol (500K) V2.0
  • 007 - INVT BMS CAN Bus protocol V1.02
  • 008 - GoodWe LV BMS Protocol (EX/EM/S-BP/BP)
  • 009 - FSS-ConnectingBat-Tl-en-10 | Version 1.0
  • 010 - MUST PV1800F-CAN communication Protocol1.04.04
  • 011 - LuxpowerTek Battery CAN protocol V01
  • 012 - CAN BUS User customization
  • 013 - CAN BUS Protocol 013
  • 014 - CAN BUS Protocol 014

YamBMS hardware

Tip

This solution only requires an ESP32 with a CAN transceiver and a RS485 transceiver.

You are free to choose the hardware you want, the list below are 3 easy to use examples of ESP32-S3 with PSRAM :

See the documentation about supported hardware.

M5Stack AtomS3 example (no welding)

The example below uses an AtomS3 (display) with the Atomic CAN base and RS485 unit.

Image

Schematic and setup instructions

Caution

Galvanic isolation of the RS485 connection is strongly recommended. The diagrams below does not show the galvanic isolation of the RS485 connection !

Important

If you are unable to read your BMS from the RS485 bus, add a 120 Ohm resistor between the A and B wires connected to your RS485 board. This must be done with the M5Stack RS485 unit, some boards have a switch to enable the bus termination resistor.

Note: the choice of RS485 board is not related to the chosen ESP32.

AtomS3 with unisolated RS485 board

┌──────────┐                 ┌───────────┐                       ┌──────────┐
│          │                 │   UART    │<-VCC--------------5V--│          │<---5V
│   BMS    │                 │    TO     │                       │   ESP32  │
│  JK-PB   │<-RJ45-P1-----B->│   RS485   │<-DI-----------TX--G1--│  Atom S3 │
│          │<-RJ45-P2-----A->│           │--RO-----------RX--G2->│          │                  ┌────────────┐             ┌────────────┐
│  RS485   │                 │ CONVERTER │<-DE--+                │          │--G5--TX-----CTX->|            |             |            |
│ NETWORK  │                 │           │<-RE--└--TALK PIN--G8--│          │<-G6--RX-----CRX--|   Atomic   |<---CAN H--->|  Inverter  |
│          │                 │           │                       │          │<-------5V------->|  CAN Base  |<---CAN L--->|            |
|          |<-RJ45-P3---GND->|           |<-GND-------------GND->|          |<-------GND------>|            |             |            |
└──────────┘                 └───────────┘                       └──────────┘                  └────────────┘             └────────────┘

ESP32-S3 with isolated RS485 board

┌──────────┐                 ┌───────────┐                       ┌──────────┐
│          │                 │   UART    │<-V1--------3V3 or 5V--│          │<---5V
│   BMS    │                 │    TO     │                       │          │
│  JK-PB   │<-RJ45-P1-----B->│   RS485   │<-RX-----------TX--17--│ ESP32-S3 │
│          │<-RJ45-P2 ----A->│           │--TX-----------RX--18->│          │                  ┌────────────┐             ┌────────────┐
│  RS485   │                 │ CONVERTER │                       │          │--38--TX-----CTX->|            |             |            |
│ NETWORK  │                 │           │      No TALK PIN (8)--│          │<-39--RX-----CRX--|    CAN     |<---CAN H--->|  Inverter  |
│          │                 │           │                       │          │<-------3V3------>| SN65HVD230 |<---CAN L--->|            |
|          |<-RJ45-P3----G2->|           |<-G1--------------GND->|          |<-------GND------>|            |             |            |
└──────────┘                 └───────────┘                       └──────────┘                  └────────────┘             └────────────┘

BMS DIP switch config (mode 2)

With mode 2, the sniffer (ESP32) will automatically take the address 0x00 and act as master BMS (max 15 BMS). This is the preferred mode with YamBMS.

  • BMS 1 RS485 address : 0x01
  • BMS 2 RS485 address : 0x02
  • BMS 3 RS485 address : 0x03
  • etc.

MODE 1 vs MODE 2

MODE 1. If there is a JK-BMS acting as REAL MASTER (i.e. it has set 0x00 address), the code will be sniffing all the traffic in the network. The problem is that there is some information that is NEVER in the sniffed traffic information (device info frame type 03): device-name, hw version, sw version, password, RCV Time, RFV Time... So, periodically, ESP code will act as a PSEUDO-MASTER to try to get this information. It works for every slave device, but not for master device. At this moment, master device does NOT broadcast by itself the "frame type 03" info. And it does not answer to a "frame type 03" request sent by PSEUDO MASTER.

MODE 2. If every JK-BMS are set as SLAVES (all of them), the ESP code will act as MASTER. So, if ESP code does not detect any REAL MASTER in the network, it will act as a MASTER. Remember to adapt DIP switches and the YAML (addresses) as well. Changing the addreses of the devices does not affect to the historic data gathered from that device, because the config is based on the NAME of the device and not on the address of the device. So, change the address, but not the name. In this mode, ESP will gather all the information (cell info, device settings and device info). If anytime, a REAL MASTER arrives to the network, ESP will detect it and will stop acting as MASTER.

JK-PB RS485 functions

Broadcasting JK-PB settings to all BMS

Image

When enabled, this function synchronizes the settings of all your BMS connected to the same RS485 network as soon as you make parameter changes.

JK-PB SoC 100% reset

Note

During the Bulk phase the YamBMS SoC cannot be more than 98%. When the battery is fully charged, the average SoC of your BMS will be sent.

Solution 1

The simplest solution is to disable the Charging Float Mode switch to disable the new SoC 100% reset logic described below in Solution 2. Your BMS will simply use the SOC 100% V. value, and the SoC will be reset to 100% as soon as a cell reaches this value.

Image

Solution 2

The new JK-PB parameters RCV and RCV timer are not used by YamBMS, but you can adjust them to reach the 100% faster, a little before YamBMS completes charging.

If you are instructing YamBMS to Bulk charge at 3.5V/cell, configure the JK-PB parameters like this:

  • JK RCV V. : 3.45V/cell
  • JK RCV timer to 0.1 hour
  • JK SOC 100% V. : 3.449V

This will reset the SoC to 100% faster.

The SoC at the end of charge is easy to understand, it's the average SoC of your BMS, but it won't go higher than 98% until charging is complete.

Then, when charging is complete before switching to Float, YamBMS will again send the average SoC of your BMS, which is assumed to have reached 100%. It's up to you to ensure this is the case by configuring your BMS.

On the YamBMS side, disabling the EOC Timer (which will end charging after max 30min in the Cut-Off phase without waiting for all cells to be equalized) will prolong charging until all your cells are equalized and the active balancer is no longer working for 60s. This can give more time to the JK-PB to reset to 100%.

Image

Erase History Data

The procedure below allows you to unblock the UART2 (RS485-2) port to restore normal behavior, depending on the DIP switch value :

  • DIP switch 0 = protocol 015 - dedicated to the master BMS
  • DIP switches 1 to 15 = protocol 001 - JK BMS RS485 Modbus V1.0
1. Generate a JK code 2. Erase History Data 3. Enter the code
Go to this page to generate a new code valid for one hour. In the JK smartphone app, click on the Erase History Data function. Enter the generated code and then click Verify.