YamBMS 1.8.1 LP/RP examples
Update the root YAML and the examples for the UART and CAN declarations, the RS485 block and the Board Options section.
This commit is contained in:
1 parent
cab5a63e0e
commit
faad9e60ce
32 files changed
+800
-989
No files matched your search
+25
-40
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -219,36 +229,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
uart_esp_1: !include packages/board/board_options_itf_uart_esp_1.yaml
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# uart_esp_2: !include packages/board/board_options_itf_uart_esp_2.yaml
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# uart_esp_3: !include packages/board/board_options_itf_uart_esp_3.yaml
|
||||
|
||||
# UART flow control
|
||||
# uart_flow_control: !include
|
||||
# file: packages/board/board_options_itf_uart_flow_control.yaml
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
canbus_node_1: !include
|
||||
file: packages/board/board_options_itf_canbus_esp32_can.yaml
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# canbus_node_2: !include
|
||||
# file: packages/board/board_options_itf_canbus_mcp2515.yaml
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# psram_octal_80Mhz: !include packages/board/board_options_PSRAM_octal_80Mhz.yaml
|
||||
|
||||
@@ -371,12 +351,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # Must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs for the ACK can_id 0x305 (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -384,15 +366,18 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# rs485_pylon: !include
|
||||
# file: packages/yambms/yambms_rs485_pylon.yaml # yambms_rs485_pylon_web_server.yaml
|
||||
# rs485_1: !include
|
||||
# file: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # file: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
+42
-49
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.27
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -133,6 +133,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -154,14 +164,14 @@ substitutions:
|
||||
# +--------------------------------------+
|
||||
# | UART expander WK2168 |
|
||||
# +--------------------------------------+
|
||||
uart0_baudrate: '2400' # uart_id : uart_${uart_hub_bus}_0 WKS {RJ45-UART0}
|
||||
uart1_baudrate: '38400' # uart_id : uart_${uart_hub_bus}_1 JSY193
|
||||
uart2_baudrate: '19200' # uart_id : uart_${uart_hub_bus}_2 SmartShunt
|
||||
uart3_baudrate: '9600' # uart_id : uart_${uart_hub_bus}_3 SRNE {RJ45-UART3}
|
||||
uart4_baudrate: '115200' # uart_id : uart_${uart_hub_bus}_4 JK-BMS 1
|
||||
uart5_baudrate: '115200' # uart_id : uart_${uart_hub_bus}_5 JK-BMS 2
|
||||
uart6_baudrate: '115200' # uart_id : uart_${uart_hub_bus}_6 Pylontech
|
||||
uart7_baudrate: '9600' # uart_id : uart_${uart_hub_bus}_7 EPEVER {RJ45-UART7}
|
||||
# uart_spi_0 : 2400 WKS {RJ45-UART0}
|
||||
# uart_spi_1 : 38400 JSY193
|
||||
# uart_spi_2 : 19200 SmartShunt
|
||||
# uart_spi_3 : 9600 SRNE {RJ45-UART3}
|
||||
# uart_spi_4 : 115200 JK-BMS 1
|
||||
# uart_spi_5 : 115200 JK-BMS 2
|
||||
# uart_spi_6 : 115200 Pylontech
|
||||
# uart_spi_7 : 9600 EPEVER {RJ45-UART7}
|
||||
|
||||
|
||||
|
||||
@@ -187,57 +197,34 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
# uart_esp_1: !include packages/board/board_options_itf_uart_esp_1.yaml
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# uart_esp_2: !include packages/board/board_options_itf_uart_esp_2.yaml
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# uart_esp_3: !include packages/board/board_options_itf_uart_esp_3.yaml
|
||||
|
||||
# BUS
|
||||
# spi_bus: !include packages/board/board_options_itf_bus_spi.yaml # SPI bus
|
||||
# i2c_bus: !include packages/board/board_options_itf_bus_i2c.yaml # I2C bus for SX1509 and BME280/BMP280
|
||||
# one_wire_bus: !include packages/board/board_options_itf_bus_one_wire.yaml # One wire bus for Dallas Temperature Sensor
|
||||
|
||||
# WK2168 UART/IO Expander
|
||||
wk2168_spi: !include packages/board/board_options_itf_wk2168_spi.yaml
|
||||
# wk2168_i2c: !include packages/board/board_options_itf_wk2168_i2c.yaml
|
||||
|
||||
# Modbus 1
|
||||
# modbus_1: !include
|
||||
# file: 'packages/board/board_options_itf_modbus_expander.yaml'
|
||||
# file: 'packages/board/board_options_itf_modbus.yaml'
|
||||
# vars:
|
||||
# modbus_id: '1' # can be a number or text or a mixture of both, e.g. full id = modbus_client_1
|
||||
# modbus_role: 'client' # client / server
|
||||
# modbus_uart_id: 'uart_${uart_hub_bus}_1'
|
||||
# modbus_uart_id: 'uart_spi_1'
|
||||
|
||||
# Modbus 2
|
||||
# modbus_2: !include
|
||||
# file: 'packages/board/board_options_itf_modbus_expander.yaml'
|
||||
# file: 'packages/board/board_options_itf_modbus.yaml'
|
||||
# vars:
|
||||
# modbus_id: '2' # can be a number or text or a mixture of both, e.g. full id = modbus_client_2
|
||||
# modbus_role: 'client' # client / server
|
||||
# modbus_uart_id: 'uart_${uart_hub_bus}_2'
|
||||
|
||||
# WK2168 UART/IO Expander
|
||||
wk2168_spi: !include packages/board/board_options_itf_pvbrain2_wk2168_spi.yaml
|
||||
# wk2168_i2c: !include packages/board/board_options_itf_pvbrain2_wk2168_i2c.yaml
|
||||
# modbus_uart_id: 'uart_spi_2'
|
||||
|
||||
# SX1509 16 channel I/O Expander
|
||||
# sx1509: !include packages/board/board_options_itf_pvbrain2_sx1509.yaml
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
canbus_node_1: !include
|
||||
file: packages/board/board_options_itf_canbus_esp32_can.yaml
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - SPI bus and MCP2515
|
||||
# canbus_node_2: !include
|
||||
# file: packages/board/board_options_itf_canbus_mcp2515.yaml
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
psram_octal_80Mhz: !include packages/board/board_options_PSRAM_octal_80Mhz.yaml
|
||||
|
||||
@@ -282,12 +269,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # Must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs for the ACK can_id 0x305 (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -295,15 +284,19 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# rs485_pylon: !include
|
||||
# file: packages/yambms/yambms_rs485_pylon_core.yaml
|
||||
# rs485_1: !include
|
||||
# file: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # file: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_${uart_hub_bus}_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_spi_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.07.30
|
||||
# Version : 1.7.1
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -117,7 +117,7 @@ substitutions:
|
||||
{ 55.0, 0.50 },
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# Temperature °C -> Discharge Rate (0.0C to 1.0C)
|
||||
# Temperature °C -> Discharge Rate (0.0C to 1.0C)
|
||||
yambms_discharging_rate_table: |
|
||||
{
|
||||
{-30.0, 0.00 },
|
||||
@@ -132,18 +132,28 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
# +--------------------------------------+
|
||||
# | BMS Settings |
|
||||
# +--------------------------------------+
|
||||
bms_update_interval: '3s' # frequency at which BMS data is refreshed, going below '3s' can cause problems
|
||||
bms_update_interval: '3s' # frequency at which BMS data is refreshed, going below '3s' can cause problems
|
||||
# +--------------------------------------+
|
||||
# | Health & LED Assignment Logs |
|
||||
# +--------------------------------------+
|
||||
enable_led_logging: 'false' # Set to true to see if an led is assigned to a component correctly, logged every 60 seconds
|
||||
enable_health_logging: 'false' # Set to true to see if component health for all component instances, logged every 60 seconds
|
||||
enable_led_logging: 'false' # Set to true to see if an led is assigned to a component correctly, logged every 60 seconds
|
||||
enable_health_logging: 'false' # Set to true to see if component health for all component instances, logged every 60 seconds
|
||||
# +--------------------------------------+
|
||||
# | Advanced options |
|
||||
# +--------------------------------------+
|
||||
@@ -219,36 +229,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
uart_esp_1: !include packages/board/board_options_itf_uart_esp_1.yaml
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# uart_esp_2: !include packages/board/board_options_itf_uart_esp_2.yaml
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# uart_esp_3: !include packages/board/board_options_itf_uart_esp_3.yaml
|
||||
|
||||
# UART flow control
|
||||
# uart_flow_control: !include
|
||||
# file: packages/board/board_options_itf_uart_flow_control.yaml
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
canbus_node_1: !include
|
||||
file: packages/board/board_options_itf_canbus_esp32_can.yaml
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# canbus_node_2: !include
|
||||
# file: packages/board/board_options_itf_canbus_mcp2515.yaml
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# psram_octal_80Mhz: !include packages/board/board_options_PSRAM_octal_80Mhz.yaml
|
||||
|
||||
@@ -289,16 +269,19 @@ packages:
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
canbus1: !include
|
||||
file: packages/yambms/yambms_canbus.yaml # yambms_canbus_web_server.yaml
|
||||
file: packages/yambms/yambms_canbus.yaml
|
||||
# file: packages/yambms/yambms_canbus_web_server.yaml
|
||||
vars:
|
||||
canbus_id: '1' # Must be a number
|
||||
canbus_id: '1' # Must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs for the ACK can_id 0x305 (required for Schneider XW Pro)
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -306,15 +289,20 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# rs485_pylon: !include
|
||||
# file: packages/yambms/yambms_rs485_pylon.yaml # yambms_rs485_pylon_web_server.yaml
|
||||
# rs485_1: !include
|
||||
# file: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # file: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# # ESP32 : uart_esp_1 to uart_esp_3
|
||||
# # WK2168 : uart_spi_0 to uart_spi_7 / uart_i2c_0 to uart_i2c_7
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -220,33 +230,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
- path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -314,12 +297,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -327,14 +312,17 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
+26
-36
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -221,33 +231,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
- path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_bms_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -280,6 +263,8 @@ packages:
|
||||
vars:
|
||||
# CAN BUS ID
|
||||
canbus_id: 'canbus_bms_1'
|
||||
canbus_platform: 'mcp2515' # esp32_can / mcp2515
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
deye_name: 'DEYE-Top 1'
|
||||
deye_id: '1'
|
||||
# Deye module 1
|
||||
@@ -323,12 +308,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -336,14 +323,17 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.29
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -220,33 +230,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
- path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -323,12 +306,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -336,14 +321,17 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -220,33 +230,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
- path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -321,12 +304,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -334,14 +319,18 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
+24
-36
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -220,33 +230,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
- path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -330,12 +313,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -343,14 +328,17 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -220,33 +230,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
- path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -274,17 +257,12 @@ packages:
|
||||
|
||||
|
||||
|
||||
# RS485 Sniffer with talk_pin (WS-RS485-CAN and other RS485 boards with a flow_control_pin)
|
||||
# - path: 'packages/bms/bms_combine_JK_RS485_Modbus_sniffer_talk_pin.yaml'
|
||||
# vars:
|
||||
# sniffer_protocol: 'JK02_32S'
|
||||
# sniffer_uart_id: 'uart_esp_1'
|
||||
# sniffer_talk_pin: ${talk_pin} # can be replaced by the GPIO number
|
||||
# RS485 Sniffer
|
||||
- path: 'packages/bms/bms_combine_JK_RS485_Modbus_sniffer.yaml'
|
||||
vars:
|
||||
sniffer_protocol: 'JK02_32S'
|
||||
sniffer_uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin} # WS-RS485-CAN and other RS485 boards with a flow_control_pin
|
||||
# BMS 1
|
||||
- path: 'packages/bms/bms_combine_JK_RS485_Modbus_JK-B_standard.yaml'
|
||||
vars:
|
||||
@@ -360,12 +338,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -373,14 +353,17 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -220,33 +230,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
- path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -274,17 +257,12 @@ packages:
|
||||
|
||||
|
||||
|
||||
# RS485 Sniffer with talk_pin (WS-RS485-CAN and other RS485 boards with a flow_control_pin)
|
||||
# - path: 'packages/bms/bms_combine_JK_RS485_Modbus_sniffer_talk_pin.yaml'
|
||||
# vars:
|
||||
# sniffer_protocol: 'JK02_32S'
|
||||
# sniffer_uart_id: 'uart_esp_1'
|
||||
# sniffer_talk_pin: ${talk_pin} # can be replaced by the GPIO number
|
||||
# RS485 Sniffer
|
||||
- path: 'packages/bms/bms_combine_JK_RS485_Modbus_sniffer.yaml'
|
||||
vars:
|
||||
sniffer_protocol: 'JK02_32S'
|
||||
sniffer_uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin} # WS-RS485-CAN and other RS485 boards with a flow_control_pin
|
||||
# BMS 1
|
||||
- path: 'packages/bms/bms_combine_JK_RS485_Modbus_bms_standard.yaml'
|
||||
vars:
|
||||
@@ -360,12 +338,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -373,14 +353,17 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
+24
-36
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -220,33 +230,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -315,12 +298,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -328,14 +313,17 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -220,33 +230,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
- path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
- path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -313,12 +296,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -326,14 +311,17 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -220,33 +230,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
- path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -310,12 +293,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -323,14 +308,17 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -220,33 +230,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
- path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -346,12 +329,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -359,14 +344,17 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -220,33 +230,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
- path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -345,12 +328,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -358,14 +343,17 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
+24
-36
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -220,33 +230,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
- path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -328,12 +311,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -341,14 +326,17 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
+24
-36
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -220,33 +230,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -360,12 +343,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -373,14 +358,17 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -187,33 +197,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
- path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -257,12 +240,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -270,14 +255,17 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.09.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -144,33 +144,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
# - path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
|
||||
+40
-46
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.27
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -133,6 +133,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -161,14 +171,14 @@ substitutions:
|
||||
# +--------------------------------------+
|
||||
# | UART expander WK2168 |
|
||||
# +--------------------------------------+
|
||||
uart0_baudrate: '2400' # uart_id : uart_${uart_hub_bus}_0 WKS {RJ45-UART0}
|
||||
uart1_baudrate: '38400' # uart_id : uart_${uart_hub_bus}_1 JSY193
|
||||
uart2_baudrate: '19200' # uart_id : uart_${uart_hub_bus}_2 SmartShunt
|
||||
uart3_baudrate: '9600' # uart_id : uart_${uart_hub_bus}_3 SRNE {RJ45-UART3}
|
||||
uart4_baudrate: '115200' # uart_id : uart_${uart_hub_bus}_4 JK-BMS 1
|
||||
uart5_baudrate: '115200' # uart_id : uart_${uart_hub_bus}_5 JK-BMS 2
|
||||
uart6_baudrate: '115200' # uart_id : uart_${uart_hub_bus}_6 Pylontech
|
||||
uart7_baudrate: '9600' # uart_id : uart_${uart_hub_bus}_7 EPEVER {RJ45-UART7}
|
||||
# uart_spi_0 : 2400 WKS {RJ45-UART0}
|
||||
# uart_spi_1 : 38400 JSY193
|
||||
# uart_spi_2 : 19200 SmartShunt
|
||||
# uart_spi_3 : 9600 SRNE {RJ45-UART3}
|
||||
# uart_spi_4 : 115200 JK-BMS 1
|
||||
# uart_spi_5 : 115200 JK-BMS 2
|
||||
# uart_spi_6 : 115200 Pylontech
|
||||
# uart_spi_7 : 9600 EPEVER {RJ45-UART7}
|
||||
|
||||
|
||||
|
||||
@@ -199,53 +209,32 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# BUS
|
||||
# - path: 'packages/board/board_options_itf_bus_spi.yaml' # SPI bus
|
||||
# - path: 'packages/board/board_options_itf_bus_i2c.yaml' # I2C bus for SX1509 and BME280/BMP280
|
||||
# - path: 'packages/board/board_options_itf_bus_one_wire.yaml' # One wire bus for Dallas Temperature Sensor
|
||||
|
||||
# WK2168 UART/IO Expander
|
||||
- path: 'packages/board/board_options_itf_wk2168_spi.yaml'
|
||||
# - path: 'packages/board/board_options_itf_wk2168_i2c.yaml'
|
||||
|
||||
# Modbus 1
|
||||
# - path: 'packages/board/board_options_itf_modbus_expander.yaml'
|
||||
# - path: 'packages/board/board_options_itf_modbus.yaml'
|
||||
# vars:
|
||||
# modbus_id: '1' # can be a number or text or a mixture of both, e.g. full id = modbus_client_1
|
||||
# modbus_role: 'client' # client / server
|
||||
# modbus_uart_id: 'uart_${uart_hub_bus}_1'
|
||||
# modbus_uart_id: 'uart_spi_1'
|
||||
|
||||
# Modbus 2
|
||||
# - path: 'packages/board/board_options_itf_modbus_expander.yaml'
|
||||
# - path: 'packages/board/board_options_itf_modbus.yaml'
|
||||
# vars:
|
||||
# modbus_id: '2' # can be a number or text or a mixture of both, e.g. full id = modbus_client_2
|
||||
# modbus_role: 'client' # client / server
|
||||
# modbus_uart_id: 'uart_${uart_hub_bus}_2'
|
||||
|
||||
# WK2168 UART/IO Expander
|
||||
- path: 'packages/board/board_options_itf_pvbrain2_wk2168_spi.yaml'
|
||||
# - path: 'packages/board/board_options_itf_pvbrain2_wk2168_i2c.yaml'
|
||||
# modbus_uart_id: 'uart_spi_2'
|
||||
|
||||
# SX1509 16 channel I/O Expander
|
||||
# - path: 'packages/board/board_options_itf_pvbrain2_sx1509.yaml'
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - SPI bus and MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
- path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -291,12 +280,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -304,14 +295,17 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon_core.yaml'
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_${uart_hub_bus}_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_spi_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.08.11
|
||||
# Version : 1.8.0
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -68,14 +68,6 @@ packages:
|
||||
# server_status_led_id: 'virtual_status_light' # led used to show status. Default = esp_light, set specific led or set to 'virtual_status_light' to disable
|
||||
# network_status_led_id: 'virtual_status_light' # led used to show status. Default = esp_light, set specific led or set to 'virtual_status_light' to disable
|
||||
|
||||
# uart
|
||||
- path: packages/board/board_options_itf_uart_1.yaml
|
||||
- path: packages/board/board_options_itf_uart_2.yaml
|
||||
- path: packages/board/board_options_itf_uart_3.yaml
|
||||
- path: packages/board/board_options_itf_uart_4.yaml
|
||||
- path: packages/board/board_options_itf_uart_5.yaml
|
||||
- path: packages/board/board_options_itf_uart_6.yaml
|
||||
|
||||
# modbus
|
||||
- path: packages/board/board_options_itf_modbus.yaml
|
||||
vars:
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.07.30
|
||||
# Version : 1.7.1
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -220,33 +230,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
- path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -290,12 +273,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -303,14 +288,20 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# # ESP32 : uart_esp_1 to uart_esp_3
|
||||
# # WK2168 : uart_spi_0 to uart_spi_7 / uart_i2c_0 to uart_i2c_7
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
# Updated : 2026.07.30
|
||||
# Version : 1.7.1
|
||||
# Updated : 2026.11.05
|
||||
# Version : 1.8.1
|
||||
# GitHub : https://github.com/Sleeper85/esphome-yambms
|
||||
|
||||
# YamBMS ( Yet another multi-BMS Merging Solution )
|
||||
@@ -132,6 +132,16 @@ substitutions:
|
||||
{ 60.0, 0.00 }
|
||||
}
|
||||
# +--------------------------------------+
|
||||
# | YamBMS services |
|
||||
# +--------------------------------------+
|
||||
# Update service : checks GitHub for a newer YamBMS version.
|
||||
# Telemetry service : sends anonymous data about your setup (BMS model, board,
|
||||
# inverter protocol, YamBMS version). It is what tells me which hardware is
|
||||
# actually in use, so I know where to spend my time. Public stats and details
|
||||
# on what is collected : stats.yambms.org
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
# +--------------------------------------+
|
||||
# | Shunt Settings |
|
||||
# +--------------------------------------+
|
||||
shunt_update_interval: '3s' # frequency at which Shunt data is refreshed
|
||||
@@ -220,33 +230,6 @@ packages:
|
||||
# | >>> Uncomment your interfaces and options
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# UART 1 (uart_id: uart_esp_1)
|
||||
- path: 'packages/board/board_options_itf_uart_esp_1.yaml'
|
||||
# UART 2 (uart_id: uart_esp_2)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_2.yaml'
|
||||
# UART 3 (uart_id: uart_esp_3)
|
||||
# - path: 'packages/board/board_options_itf_uart_esp_3.yaml'
|
||||
|
||||
# UART flow control
|
||||
# - path: 'packages/board/board_options_itf_uart_flow_control.yaml'
|
||||
# vars:
|
||||
# uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin}
|
||||
|
||||
# CAN transceiver - ESP32_CAN (TJA105x, SN65HVD230, M5Stack CAN base/unit)
|
||||
- path: 'packages/board/board_options_itf_canbus_esp32_can.yaml'
|
||||
vars:
|
||||
# to bms = canbus_bms_1
|
||||
# to inverter = canbus_inverter_1
|
||||
canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# CAN transceiver - MCP2515
|
||||
# - path: 'packages/board/board_options_itf_canbus_mcp2515.yaml'
|
||||
# vars:
|
||||
# # to bms = canbus_bms_1
|
||||
# # to inverter = canbus_inverter_1
|
||||
# canbus_node_id: 'canbus_inverter_1'
|
||||
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
@@ -290,12 +273,14 @@ packages:
|
||||
vars:
|
||||
canbus_id: '1' # must be a number
|
||||
canbus_name: 'CANBUS 1'
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# CAN frames sending will be paused for `30s` if the inverter does not respond with an ACK (can_id 0x305) before the end of the `canbus_link_timer` (5s by default).
|
||||
canbus_link_timer_enabled: 'true' # Set it to 'false' if your inverter/charger is not sending ACK (can_id 0x305) every `1s` as specified by the protocol
|
||||
canbus_link_timer: '5s'
|
||||
canbus_extended_ack: 'false' # Set to 'true' for enable extended 29-bit IDs (required for Schneider XW Pro)
|
||||
canbus_link_timer: '10s' # min 6s with Deye
|
||||
# CAN setup
|
||||
canbus_platform: 'esp32_can' # esp32_can / mcp2515
|
||||
canbus_node_id: 'canbus_inverter_1' # CAN bus node to which your inverter is connected
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
|
||||
|
||||
|
||||
@@ -303,14 +288,18 @@ packages:
|
||||
# | >>> RS485 bus to Inverter
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
# - path: 'packages/yambms/yambms_rs485_pylon.yaml' # yambms_rs485_pylon_web_server.yaml
|
||||
# - path: 'packages/yambms/yambms_rs485.yaml'
|
||||
# # - path: 'packages/yambms/yambms_rs485_web_server.yaml'
|
||||
# vars:
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_id: '1' # Must be a number
|
||||
# rs485_name: 'RS485 1'
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600'
|
||||
# rs485_protocol: 'pylon' # pylon / voltronic
|
||||
# rs485_update_timeout: '10s'
|
||||
# rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# # UART setup
|
||||
# rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
|
||||
|
||||
|
||||
# +------------------------------------------------------------------------------+
|
||||
|
||||
@@ -71,6 +71,7 @@ api:
|
||||
> Please note that enabling this component will take up a lot of memory and may decrease stability and be the cause of reboot depending on the capabilities of the board used.
|
||||
|
||||
If you don't use `Home Assistant`, you can activate the `Web Server` and have access to YamBMS information and also interact with the application.
|
||||
To do so, include the `yambms_web_server.yaml` package, see [Board options](#board-options).
|
||||
|
||||
[ESPHome Web Server Component](https://esphome.io/components/web_server.html)
|
||||
|
||||
@@ -93,55 +94,52 @@ So just one of the packages below :
|
||||
### ESP32 Generic
|
||||
|
||||
```YAML
|
||||
device_board: !include packages/board/board_ESP32_Generic.yaml
|
||||
board: !include packages/board/board_ESP32_Generic.yaml
|
||||
```
|
||||
|
||||
### ESP32 DevKit-V1
|
||||
|
||||
```YAML
|
||||
device_board: !include packages/board/board_ESP32_DevKit-V1.yaml
|
||||
board: !include packages/board/board_ESP32_DevKit-V1.yaml
|
||||
```
|
||||
|
||||
### ESP32-S3 DevKitC-1
|
||||
|
||||
```YAML
|
||||
# RGB LED to GPIO 38
|
||||
device_board: !include packages/board/board_ESP32-S3_DevKitC-1_LED-38.yaml
|
||||
board: !include packages/board/board_ESP32-S3_DevKitC-1_LED-38.yaml
|
||||
```
|
||||
|
||||
```YAML
|
||||
# RGB LED to GPIO 48
|
||||
device_board: !include packages/board/board_ESP32-S3_DevKitC-1_LED-48.yaml
|
||||
board: !include packages/board/board_ESP32-S3_DevKitC-1_LED-48.yaml
|
||||
```
|
||||
|
||||
### Atom S3 Lite
|
||||
|
||||
```YAML
|
||||
device_board: !include packages/board/board_ESP32-S3_AtomS3-Lite.yaml
|
||||
board: !include packages/board/board_ESP32-S3_AtomS3-Lite.yaml
|
||||
```
|
||||
|
||||
### Atom S3 / S3R (display)
|
||||
|
||||
In this case you need to specify the `yambms` and `canbus` IDs to display the information on the screen.
|
||||
The screen is a separate package, `board_options_display_128x128.yaml`, to include next to the board.
|
||||
|
||||
```YAML
|
||||
device_board: !include
|
||||
file: packages/board/board_ESP32-S3_AtomS3.yaml
|
||||
vars:
|
||||
display_auto_next_page_interval: '5s'
|
||||
```
|
||||
board: !include packages/board/board_ESP32-S3_AtomS3.yaml
|
||||
# board: !include packages/board/board_ESP32-S3_AtomS3R.yaml
|
||||
|
||||
```YAML
|
||||
device_board: !include
|
||||
file: packages/board/board_ESP32-S3_AtomS3R.yaml
|
||||
board_display: !include
|
||||
file: packages/board/board_options_display_128x128.yaml
|
||||
vars:
|
||||
display_auto_next_page_interval: '5s'
|
||||
display_rotation: '0' # 0/90/180/270 rotation angle in degrees
|
||||
```
|
||||
|
||||
### ESP32-C3 DevKitM-1
|
||||
|
||||
```YAML
|
||||
device_board: !include packages/board_ESP32-C3_DevKitM-1.yaml
|
||||
board: !include packages/board/board_ESP32-C3_DevKitM-1.yaml
|
||||
```
|
||||
|
||||
### ESP32-C3 ETH01-EVO
|
||||
@@ -149,13 +147,13 @@ In this case you need to specify the `yambms` and `canbus` IDs to display the in
|
||||
This board has an `Ethernet` port and can be powered from `POE` (optional).
|
||||
|
||||
```YAML
|
||||
device_board: !include packages/board/board_ESP32-C3_ETH01-EVO.yaml
|
||||
board: !include packages/board/board_ESP32-C3_ETH01-EVO.yaml
|
||||
```
|
||||
|
||||
### ESP32 LilyGo T-CAN485
|
||||
|
||||
```YAML
|
||||
device_board: !include packages/board/board_ESP32_LilyGo-T-CAN485.yaml
|
||||
board: !include packages/board/board_ESP32_LilyGo-T-CAN485.yaml
|
||||
```
|
||||
> [!NOTE]
|
||||
> The device has an integrated 120 Ohm termination resistor. If used as a node in the middle, this resistor must be removed. 
|
||||
@@ -163,7 +161,7 @@ This board has an `Ethernet` port and can be powered from `POE` (optional).
|
||||
### ESP32-S3 LilyGo T-Connect
|
||||
|
||||
```YAML
|
||||
device_board: !include packages/board/board_ESP32-S3_LilyGo-T-Connect.yaml
|
||||
board: !include packages/board/board_ESP32-S3_LilyGo-T-Connect.yaml
|
||||
```
|
||||
> [!NOTE]
|
||||
> The device has an integrated 120 Ohm termination resistor. If used as a node in the middle, this resistor must be removed.
|
||||
@@ -171,11 +169,34 @@ This board has an `Ethernet` port and can be powered from `POE` (optional).
|
||||
### ESP32-S3 LilyGo T-Connect Pro
|
||||
|
||||
```YAML
|
||||
device_board: !include packages/board/board_ESP32-S3_LilyGo-T-Connect-Pro.yaml
|
||||
board: !include packages/board/board_ESP32-S3_LilyGo-T-Connect-Pro.yaml
|
||||
```
|
||||
> [!NOTE]
|
||||
> The device has an integrated 120 Ohm termination resistor. If used as a node in the middle, this resistor must be removed.
|
||||
|
||||
## Board options
|
||||
|
||||
Uncomment the options you need. Boards with a screen also need their display package, see the
|
||||
`Board Display` block of the [example YAML](../../YamBMS_Local_Packages_example.yaml).
|
||||
|
||||
```YAML
|
||||
# PSRAM octal 80Mhz
|
||||
# psram_octal_80Mhz: !include packages/board/board_options_PSRAM_octal_80Mhz.yaml
|
||||
|
||||
# Web Server
|
||||
# web_server: !include packages/yambms/yambms_web_server.yaml
|
||||
|
||||
# WiFi AP @ 192.168.4.1
|
||||
# wifi_ap: !include packages/board/board_options_wifi_ap.yaml
|
||||
|
||||
# Captive Portal @ 192.168.4.1
|
||||
# captive_portal: !include packages/board/board_options_captive_portal.yaml
|
||||
```
|
||||
|
||||
> [!NOTE]
|
||||
> UART and CAN interfaces are not included here. Each package declares its own, from its
|
||||
> `*_uart_id` or `canbus_platform` var.
|
||||
|
||||
## YamBMS single-node example
|
||||
|
||||
```YAML
|
||||
@@ -184,6 +205,7 @@ This board has an `Ethernet` port and can be powered from `POE` (optional).
|
||||
vars:
|
||||
shunt_id: '1' # must be a number
|
||||
shunt_name: 'Shunt 1'
|
||||
shunt_uart_id: 'uart_esp_1'
|
||||
# other settings
|
||||
# ...
|
||||
|
||||
@@ -192,14 +214,16 @@ This board has an `Ethernet` port and can be powered from `POE` (optional).
|
||||
vars:
|
||||
bms_id: '1' # must be a number
|
||||
bms_name: 'BMS 1'
|
||||
bms_uart_id: 'uart_esp_2'
|
||||
# other settings
|
||||
# ...
|
||||
|
||||
bms2: !include
|
||||
file: packages/bms/bms_combine_JBD_UART_full.yaml
|
||||
file: packages/bms/bms_combine_JBD_BLE_full.yaml
|
||||
vars:
|
||||
bms_id: '2' # must be a number
|
||||
bms_name: 'BMS 2'
|
||||
bms_ble_mac_address: 11:22:33:44:55:77
|
||||
# other settings
|
||||
# ...
|
||||
|
||||
@@ -220,7 +244,7 @@ This board has an `Ethernet` port and can be powered from `POE` (optional).
|
||||
|
||||
```YAML
|
||||
modbus: !include
|
||||
file: packages/base/device_modbus.yaml
|
||||
file: packages/board/board_options_itf_modbus.yaml
|
||||
vars:
|
||||
modbus_role: 'client' # client / server
|
||||
modbus_uart_id: 'uart_esp_1' # RS485 board
|
||||
@@ -254,7 +278,7 @@ This board has an `Ethernet` port and can be powered from `POE` (optional).
|
||||
|
||||
```YAML
|
||||
modbus: !include
|
||||
file: packages/base/device_modbus.yaml
|
||||
file: packages/board/board_options_itf_modbus.yaml
|
||||
vars:
|
||||
modbus_role: 'server' # client / server
|
||||
modbus_uart_id: 'uart_esp_1' # RS485 board
|
||||
@@ -287,7 +311,7 @@ This board has an `Ethernet` port and can be powered from `POE` (optional).
|
||||
|
||||
```YAML
|
||||
modbus: !include
|
||||
file: packages/base/device_modbus.yaml
|
||||
file: packages/board/board_options_itf_modbus.yaml
|
||||
vars:
|
||||
modbus_role: 'server' # client / server
|
||||
modbus_uart_id: 'uart_esp_1' # RS485 board
|
||||
@@ -354,40 +378,59 @@ As soon as the balancer is available/online the values `equalizing` and `b
|
||||
|
||||
Take the time to configure `YamBMS` correctly according to your battery chemistry type `LFP/Li-ion/LTO` and `cell count`. Charging voltages can be changed in the app.
|
||||
|
||||
The YamBMS settings are `substitutions`, not `vars`, because the other packages read them too
|
||||
(`yambms_id` for instance is used by the CAN and RS485 packages). Set them in the
|
||||
`substitutions:` block at the top of your YAML :
|
||||
|
||||
```YAML
|
||||
yambms1: !include
|
||||
file: packages/yambms/yambms.yaml
|
||||
vars:
|
||||
# Please read the cut-off charging logic README to understand how the YamBMS works
|
||||
yambms_id: 'yambms1'
|
||||
yambms_name: 'YamBMS 1'
|
||||
yambms_update_interval: '1s'
|
||||
# Input numbers can be displayed as a slider or an input box, options are 'slider' or 'box'.
|
||||
yambms_input_number_mode: 'slider'
|
||||
# Please check and fill in the options below correctly according to your battery chemistry and number of cells in series.
|
||||
# These parameters are important and used for charging logic.
|
||||
# Battery Chemistry
|
||||
yambms_battery_chemistry: '1' # 1-LFP | 2-Li-ion | 3-LTO
|
||||
# Number of cells in series
|
||||
yambms_cell_count: '16'
|
||||
# Bulk / Absorption Voltage : corresponds to the Bulk voltage that will be used to charge the battery. (LFP : 55.2V = 3.45V/Cell for 16S battery)
|
||||
yambms_bulk_v: '55.2'
|
||||
# Float Voltage : corresponds to the voltage at which the battery would be maintained at the end of charge. (LFP : 53.6V = 3.35V/Cell for 16S battery)
|
||||
yambms_float_v: '53.6'
|
||||
# Rebulk voltage, voltage from which a new Bulk charge can start. (LFP : 52.8V = 3.3V/Cell for 16S battery)
|
||||
yambms_rebulk_v: '52.8'
|
||||
# Maximum time in minutes that the cut-off step can last before charging is complete
|
||||
# If your cells are properly balanced this step ends at the fastest after the `cut-off timer`
|
||||
# This timer can be deactivated with a switch
|
||||
yambms_eoc_timer: '30'
|
||||
# Time in seconds during which the end of charge conditions must be respected (cut-off + cells not equalizing)
|
||||
yambms_cutoff_timer: '60'
|
||||
# Max. charge current : corresponds to the maximum charge current which may be requested by YamBMS.
|
||||
# The current requested will be proportional to the BMS count without ever exceeding this value.
|
||||
yambms_max_requested_charge_current: '300' # in Ampere
|
||||
# Max. discharge current : corresponds to the maximum discharge current which may be requested by YamBMS.
|
||||
# The current requested will be proportional to the BMS count without ever exceeding this value.
|
||||
yambms_max_requested_discharge_current: '300' # in Ampere
|
||||
substitutions:
|
||||
# Please read the cut-off charging logic README to understand how the YamBMS works
|
||||
yambms_id: '1' # Number without spaces
|
||||
yambms_name: 'YamBMS 1' # Prefix for YamBMS entities
|
||||
yambms_update_interval: '1s'
|
||||
# Input numbers can be displayed as a slider or an input box, options are 'slider' or 'box'.
|
||||
yambms_input_number_mode: 'slider'
|
||||
# Please check and fill in the options below correctly according to your battery chemistry and number of cells in series.
|
||||
# These parameters are important and used for charging logic.
|
||||
# Battery Chemistry
|
||||
yambms_battery_chemistry: '1' # 1-LFP | 2-Li-ion | 3-LTO
|
||||
# Number of cells in series
|
||||
yambms_cell_count: '16'
|
||||
# Bulk / Absorption Voltage : corresponds to the Bulk voltage that will be used to charge the battery. (LFP : 55.2V = 3.45V/Cell for 16S battery)
|
||||
yambms_bulk_v: '55.2'
|
||||
# Float Voltage : corresponds to the voltage at which the battery would be maintained at the end of charge. (LFP : 53.6V = 3.35V/Cell for 16S battery)
|
||||
yambms_float_v: '53.6'
|
||||
# Rebulk voltage, voltage from which a new Bulk charge can start. (LFP : 52.8V = 3.3V/Cell for 16S battery)
|
||||
yambms_rebulk_v: '52.8'
|
||||
# Maximum time in minutes that the cut-off step can last before charging is complete
|
||||
# If your cells are properly balanced this step ends at the fastest after the `cut-off timer`
|
||||
# This timer can be deactivated with a switch
|
||||
yambms_eoc_timer: '30'
|
||||
# Time in seconds during which the end of charge conditions must be respected (cut-off + cells not equalizing)
|
||||
yambms_cutoff_timer: '180'
|
||||
# Max. charge current : corresponds to the maximum charge current which may be requested by YamBMS.
|
||||
# The current requested will be proportional to the BMS count without ever exceeding this value.
|
||||
yambms_max_requested_charge_current: '300' # in Ampere
|
||||
# Max. discharge current : corresponds to the maximum discharge current which may be requested by YamBMS.
|
||||
# The current requested will be proportional to the BMS count without ever exceeding this value.
|
||||
yambms_max_requested_discharge_current: '300' # in Ampere
|
||||
```
|
||||
|
||||
Then include the package below `packages:`, with no `vars:` :
|
||||
|
||||
```YAML
|
||||
yambms: !include packages/yambms/yambms.yaml
|
||||
```
|
||||
|
||||
### YamBMS services
|
||||
|
||||
The update service checks for a newer YamBMS version. The telemetry service sends anonymous data
|
||||
about your setup, see [Telemetry](Telemetry.md). Both are enabled by default and set in the same
|
||||
`substitutions:` block :
|
||||
|
||||
```YAML
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
```
|
||||
|
||||
## CAN bus to Inverter
|
||||
@@ -396,6 +439,10 @@ Take the time to configure `YamBMS` correctly according to your battery chemistr
|
||||
> This package is only used with the `YamBMS` main node.
|
||||
> It's possible to use this package multiple times in order to send information on two different `CAN` bus.
|
||||
|
||||
> [!WARNING]
|
||||
> Each declared `CAN` or `RS485` link divides the requested CCL/DCL, even when its `Protocol` is `Disabled`.
|
||||
> Only declare the links actually wired to an inverter/charger, see [Multi-inverter / multi-charger](YamBMS_functions.md#multi-inverter--multi-charger).
|
||||
|
||||
The CAN bus connected to your inverter via the CAN transceiver `canbus_inverter_1`.
|
||||
|
||||
> [!NOTE]
|
||||
@@ -426,12 +473,21 @@ You can keep the default configuration and adapt the `canbus` node on which the
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
```
|
||||
|
||||
# RS485 bus to Inverter
|
||||
> [!IMPORTANT]
|
||||
> After flashing, select the `Inverter brand` of this link in Home Assistant or the web server.
|
||||
> The link stays inactive until this is done. If your brand is not listed, select `Other` and set
|
||||
> `Protocol` yourself, see [Supported devices](Supported_devices.md).
|
||||
|
||||
## RS485 bus to Inverter
|
||||
|
||||
> [!TIP]
|
||||
> This package is only used with the `YamBMS` main node.
|
||||
> It's possible to use this package multiple times in order to send information on two different `RS485` bus.
|
||||
|
||||
> [!WARNING]
|
||||
> Each declared `CAN` or `RS485` link divides the requested CCL/DCL, even when its `Protocol` is `Disabled`.
|
||||
> Only declare the links actually wired to an inverter/charger, see [Multi-inverter / multi-charger](YamBMS_functions.md#multi-inverter--multi-charger).
|
||||
|
||||
The RS485 bus connected to your inverter via the RS485 transceiver `uart_esp_3`.
|
||||
|
||||
> [!NOTE]
|
||||
@@ -454,9 +510,16 @@ You can keep the default configuration and adapt the `uart` port on which the co
|
||||
rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# UART setup
|
||||
rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# ESP32 : uart_esp_1 to uart_esp_3
|
||||
# WK2168 : uart_spi_0 to uart_spi_7 / uart_i2c_0 to uart_i2c_7
|
||||
rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
```
|
||||
|
||||
> [!IMPORTANT]
|
||||
> After flashing, select the `Inverter brand` of this link in Home Assistant or the web server.
|
||||
> The link stays inactive until this is done. If your brand is not listed, select `Other` and set
|
||||
> `Protocol` yourself, see [Supported devices](Supported_devices.md).
|
||||
|
||||
## Debug
|
||||
|
||||
The `debug` package will add useful information to refer to if problems occur.
|
||||
|
||||
@@ -71,6 +71,7 @@ api:
|
||||
> Please note that enabling this component will take up a lot of memory and may decrease stability and be the cause of reboot depending on the capabilities of the board used.
|
||||
|
||||
If you don't use `Home Assistant`, you can activate the `Web Server` and have access to YamBMS information and also interact with the application.
|
||||
To do so, include the `yambms_web_server.yaml` package, see [Board options](#board-options).
|
||||
|
||||
[ESPHome Web Server Component](https://esphome.io/components/web_server.html)
|
||||
|
||||
@@ -137,17 +138,13 @@ So just one of the packages below :
|
||||
|
||||
### Atom S3 / S3R (display)
|
||||
|
||||
In this case you need to specify the `yambms` and `canbus` IDs to display the information on the screen.
|
||||
The screen is a separate package, `board_options_display_128x128.yaml`, to include next to the board.
|
||||
|
||||
```YAML
|
||||
- path: 'packages/board/board_ESP32-S3_AtomS3.yaml'
|
||||
vars:
|
||||
display_auto_next_page_interval: '5s'
|
||||
display_rotation: '0' # 0/90/180/270 rotation angle in degrees
|
||||
```
|
||||
# - path: 'packages/board/board_ESP32-S3_AtomS3R.yaml'
|
||||
|
||||
```YAML
|
||||
- path: 'packages/board/board_ESP32-S3_AtomS3R.yaml'
|
||||
- path: 'packages/board/board_options_display_128x128.yaml'
|
||||
vars:
|
||||
display_auto_next_page_interval: '5s'
|
||||
display_rotation: '0' # 0/90/180/270 rotation angle in degrees
|
||||
@@ -156,7 +153,7 @@ In this case you need to specify the `yambms` and `canbus` IDs to display the in
|
||||
### ESP32-C3 DevKitM-1
|
||||
|
||||
```YAML
|
||||
- path: 'packages/board_ESP32-C3_DevKitM-1.yaml'
|
||||
- path: 'packages/board/board_ESP32-C3_DevKitM-1.yaml'
|
||||
```
|
||||
|
||||
### ESP32-C3 ETH01-EVO
|
||||
@@ -191,6 +188,29 @@ This board has an `Ethernet` port and can be powered from `POE` (optional).
|
||||
> [!NOTE]
|
||||
> The device has an integrated 120 Ohm termination resistor. If used as a node in the middle, this resistor must be removed.
|
||||
|
||||
## Board options
|
||||
|
||||
Uncomment the options you need. Boards with a screen also need their display package, see the
|
||||
`Board Display` block of the [example YAML](../../YamBMS_Remote_Packages_example.yaml).
|
||||
|
||||
```YAML
|
||||
# PSRAM octal 80Mhz
|
||||
# - path: 'packages/board/board_options_PSRAM_octal_80Mhz.yaml'
|
||||
|
||||
# Web Server
|
||||
# - path: 'packages/yambms/yambms_web_server.yaml'
|
||||
|
||||
# WiFi AP @ 192.168.4.1
|
||||
# - path: 'packages/board/board_options_wifi_ap.yaml'
|
||||
|
||||
# Captive Portal @ 192.168.4.1
|
||||
# - path: 'packages/board/board_options_captive_portal.yaml'
|
||||
```
|
||||
|
||||
> [!NOTE]
|
||||
> UART and CAN interfaces are not included here. Each package declares its own, from its
|
||||
> `*_uart_id` or `canbus_platform` var.
|
||||
|
||||
## YamBMS [single-node](../../examples/single-node/) example
|
||||
|
||||
```YAML
|
||||
@@ -206,7 +226,8 @@ This board has an `Ethernet` port and can be powered from `POE` (optional).
|
||||
vars:
|
||||
bms_id: '1' # must be a number
|
||||
bms_name: 'BMS 1'
|
||||
- # other settings
|
||||
bms_uart_id: 'uart_esp_2'
|
||||
# other settings
|
||||
# ...
|
||||
|
||||
# BMS 2
|
||||
@@ -214,6 +235,7 @@ This board has an `Ethernet` port and can be powered from `POE` (optional).
|
||||
vars:
|
||||
bms_id: '2' # must be a number
|
||||
bms_name: 'BMS 2'
|
||||
bms_ble_mac_address: 11:22:33:44:55:77
|
||||
# other settings
|
||||
# ...
|
||||
|
||||
@@ -234,7 +256,7 @@ This board has an `Ethernet` port and can be powered from `POE` (optional).
|
||||
|
||||
```YAML
|
||||
# Modbus client
|
||||
- path: 'packages/base/device_modbus.yaml'
|
||||
- path: 'packages/board/board_options_itf_modbus.yaml'
|
||||
vars:
|
||||
modbus_role: 'client' # client / server
|
||||
modbus_uart_id: 'uart_esp_1' # RS485 board
|
||||
@@ -264,7 +286,7 @@ This board has an `Ethernet` port and can be powered from `POE` (optional).
|
||||
|
||||
```YAML
|
||||
# Modbus server
|
||||
- path: 'packages/base/device_modbus.yaml'
|
||||
- path: 'packages/board/board_options_itf_modbus.yaml'
|
||||
vars:
|
||||
modbus_role: 'server' # client / server
|
||||
modbus_uart_id: 'uart_esp_1' # RS485 board
|
||||
@@ -294,7 +316,7 @@ This board has an `Ethernet` port and can be powered from `POE` (optional).
|
||||
|
||||
```YAML
|
||||
# Modbus server
|
||||
- path: 'packages/base/device_modbus.yaml'
|
||||
- path: 'packages/board/board_options_itf_modbus.yaml'
|
||||
vars:
|
||||
modbus_role: 'server' # client / server
|
||||
modbus_uart_id: 'uart_esp_1' # RS485 board
|
||||
@@ -359,44 +381,59 @@ As soon as the balancer is available/online the values `equalizing` and `b
|
||||
|
||||
Take the time to configure `YamBMS` correctly according to your battery chemistry type `LFP/Li-ion/LTO` and `cell count`. Charging voltages can be changed in the app.
|
||||
|
||||
The YamBMS settings are `substitutions`, not `vars`, because the other packages read them too
|
||||
(`yambms_id` for instance is used by the CAN and RS485 packages). Set them in the
|
||||
`substitutions:` block at the top of your YAML :
|
||||
|
||||
```YAML
|
||||
substitutions:
|
||||
# Please read the cut-off charging logic README to understand how the YamBMS works
|
||||
yambms_id: '1' # Number without spaces
|
||||
yambms_name: 'YamBMS 1' # Prefix for YamBMS entities
|
||||
yambms_update_interval: '1s'
|
||||
# Input numbers can be displayed as a slider or an input box, options are 'slider' or 'box'.
|
||||
yambms_input_number_mode: 'slider'
|
||||
# Please check and fill in the options below correctly according to your battery chemistry and number of cells in series.
|
||||
# These parameters are important and used for charging logic.
|
||||
# Battery Chemistry
|
||||
yambms_battery_chemistry: '1' # 1-LFP | 2-Li-ion | 3-LTO
|
||||
# Number of cells in series
|
||||
yambms_cell_count: '16'
|
||||
# Bulk / Absorption Voltage : corresponds to the Bulk voltage that will be used to charge the battery. (LFP : 55.2V = 3.45V/Cell for 16S battery)
|
||||
yambms_bulk_v: '55.2'
|
||||
# Float Voltage : corresponds to the voltage at which the battery would be maintained at the end of charge. (LFP : 53.6V = 3.35V/Cell for 16S battery)
|
||||
yambms_float_v: '53.6'
|
||||
# Rebulk voltage, voltage from which a new Bulk charge can start. (LFP : 52.8V = 3.3V/Cell for 16S battery)
|
||||
yambms_rebulk_v: '52.8'
|
||||
# Maximum time in minutes that the cut-off step can last before charging is complete
|
||||
# If your cells are properly balanced this step ends at the fastest after the `cut-off timer`
|
||||
# This timer can be deactivated with a switch
|
||||
yambms_eoc_timer: '30'
|
||||
# Time in seconds during which the end of charge conditions must be respected (cut-off + cells not equalizing)
|
||||
yambms_cutoff_timer: '180'
|
||||
# Max. charge current : corresponds to the maximum charge current which may be requested by YamBMS.
|
||||
# The current requested will be proportional to the BMS count without ever exceeding this value.
|
||||
yambms_max_requested_charge_current: '300' # in Ampere
|
||||
# Max. discharge current : corresponds to the maximum discharge current which may be requested by YamBMS.
|
||||
# The current requested will be proportional to the BMS count without ever exceeding this value.
|
||||
yambms_max_requested_discharge_current: '300' # in Ampere
|
||||
```
|
||||
|
||||
Then include the package, with no `vars:` :
|
||||
|
||||
```YAML
|
||||
yambms:
|
||||
url: https://github.com/Sleeper85/esphome-yambms
|
||||
ref: main
|
||||
refresh: 0s
|
||||
files:
|
||||
- path: 'packages/yambms/yambms.yaml'
|
||||
vars:
|
||||
# Please read the cut-off charging logic README to understand how the YamBMS works
|
||||
yambms_id: 'yambms1'
|
||||
yambms_name: 'YamBMS 1'
|
||||
yambms_update_interval: '1s'
|
||||
# Input numbers can be displayed as a slider or an input box, options are 'slider' or 'box'.
|
||||
yambms_input_number_mode: 'slider'
|
||||
# Please check and fill in the options below correctly according to your battery chemistry and number of cells in series.
|
||||
# These parameters are important and used for charging logic.
|
||||
# Battery Chemistry
|
||||
yambms_battery_chemistry: '1' # 1-LFP | 2-Li-ion | 3-LTO
|
||||
# Number of cells in series
|
||||
yambms_cell_count: '16'
|
||||
# Bulk / Absorption Voltage : corresponds to the Bulk voltage that will be used to charge the battery. (LFP : 55.2V = 3.45V/Cell for 16S battery)
|
||||
yambms_bulk_v: '55.2'
|
||||
# Float Voltage : corresponds to the voltage at which the battery would be maintained at the end of charge. (LFP : 53.6V = 3.35V/Cell for 16S battery)
|
||||
yambms_float_v: '53.6'
|
||||
# Rebulk voltage, voltage from which a new Bulk charge can start. (LFP : 52.8V = 3.3V/Cell for 16S battery)
|
||||
yambms_rebulk_v: '52.8'
|
||||
# Maximum time in minutes that the cut-off step can last before charging is complete
|
||||
# If your cells are properly balanced this step ends at the fastest after the `cut-off timer`
|
||||
# This timer can be deactivated with a switch
|
||||
yambms_eoc_timer: '30'
|
||||
# Time in seconds during which the end of charge conditions must be respected (cut-off + cells not equalizing)
|
||||
yambms_cutoff_timer: '60'
|
||||
# Max. charge current : corresponds to the maximum charge current which may be requested by YamBMS.
|
||||
# The current requested will be proportional to the BMS count without ever exceeding this value.
|
||||
yambms_max_requested_charge_current: '300' # in Ampere
|
||||
# Max. discharge current : corresponds to the maximum discharge current which may be requested by YamBMS.
|
||||
# The current requested will be proportional to the BMS count without ever exceeding this value.
|
||||
yambms_max_requested_discharge_current: '300' # in Ampere
|
||||
```
|
||||
|
||||
### YamBMS services
|
||||
|
||||
The update service checks for a newer YamBMS version. The telemetry service sends anonymous data
|
||||
about your setup, see [Telemetry](Telemetry.md). Both are enabled by default and set in the same
|
||||
`substitutions:` block :
|
||||
|
||||
```YAML
|
||||
yambms_update_service: 'true' # Set to false to disable update checks
|
||||
yambms_telemetry_service: 'true' # Set to false to disable the sending of telemetry data
|
||||
```
|
||||
|
||||
## CAN bus to Inverter
|
||||
@@ -405,6 +442,10 @@ Take the time to configure `YamBMS` correctly according to your battery chemistr
|
||||
> This package is only used with the `YamBMS` main node.
|
||||
> It's possible to use this package multiple times in order to send information on two different `CAN` bus.
|
||||
|
||||
> [!WARNING]
|
||||
> Each declared `CAN` or `RS485` link divides the requested CCL/DCL, even when its `Protocol` is `Disabled`.
|
||||
> Only declare the links actually wired to an inverter/charger, see [Multi-inverter / multi-charger](YamBMS_functions.md#multi-inverter--multi-charger).
|
||||
|
||||
The CAN bus connected to your inverter via the CAN transceiver `canbus_inverter_1`.
|
||||
|
||||
> [!NOTE]
|
||||
@@ -438,12 +479,21 @@ You can keep the default configuration and adapt the `canbus` node on which the
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
```
|
||||
|
||||
# RS485 bus to Inverter
|
||||
> [!IMPORTANT]
|
||||
> After flashing, select the `Inverter brand` of this link in Home Assistant or the web server.
|
||||
> The link stays inactive until this is done. If your brand is not listed, select `Other` and set
|
||||
> `Protocol` yourself, see [Supported devices](Supported_devices.md).
|
||||
|
||||
## RS485 bus to Inverter
|
||||
|
||||
> [!TIP]
|
||||
> This package is only used with the `YamBMS` main node.
|
||||
> It's possible to use this package multiple times in order to send information on two different `RS485` bus.
|
||||
|
||||
> [!WARNING]
|
||||
> Each declared `CAN` or `RS485` link divides the requested CCL/DCL, even when its `Protocol` is `Disabled`.
|
||||
> Only declare the links actually wired to an inverter/charger, see [Multi-inverter / multi-charger](YamBMS_functions.md#multi-inverter--multi-charger).
|
||||
|
||||
The RS485 bus connected to your inverter via the RS485 transceiver `uart_esp_3`.
|
||||
|
||||
> [!NOTE]
|
||||
@@ -470,9 +520,16 @@ You can keep the default configuration and adapt the `uart` port on which the co
|
||||
rs485_status_led_id: 'esp_light' # LED used to show status; default = esp_light, comment out to disable
|
||||
# UART setup
|
||||
rs485_uart_id: 'uart_esp_3' # UART interface to which your inverter is connected
|
||||
# ESP32 : uart_esp_1 to uart_esp_3
|
||||
# WK2168 : uart_spi_0 to uart_spi_7 / uart_i2c_0 to uart_i2c_7
|
||||
rs485_uart_baud_rate: '9600' # Default : 9600 / Epever : 115200
|
||||
```
|
||||
|
||||
> [!IMPORTANT]
|
||||
> After flashing, select the `Inverter brand` of this link in Home Assistant or the web server.
|
||||
> The link stays inactive until this is done. If your brand is not listed, select `Other` and set
|
||||
> `Protocol` yourself, see [Supported devices](Supported_devices.md).
|
||||
|
||||
## Debug
|
||||
|
||||
The `debug` package will add useful information to refer to if problems occur.
|
||||
|
||||
@@ -32,6 +32,8 @@ packages:
|
||||
vars:
|
||||
# CAN BUS ID
|
||||
canbus_id: 'canbus_bms_1'
|
||||
canbus_platform: 'mcp2515' # esp32_can / mcp2515
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
deye_name: 'DEYE-Top 1'
|
||||
deye_id: '1'
|
||||
|
||||
|
||||
@@ -29,19 +29,12 @@ packages:
|
||||
# The sniffer represents the ESP node connected to the JK-BMS PB RS485 bus
|
||||
# If address 0x00 is not detected on the RS485 bus, the sniffer will act directly as a master BMS (mode 2, max 15 BMS)
|
||||
|
||||
# RS485 Sniffer with talk_pin (WS-RS485-CAN and other RS485 boards with a flow_control_pin)
|
||||
# sniffer1: !include
|
||||
# file: packages/bms/bms_combine_JK_RS485_Modbus_sniffer_talk_pin.yaml
|
||||
# vars:
|
||||
# sniffer_protocol: 'JK02_32S'
|
||||
# sniffer_uart_id: 'uart_esp_1'
|
||||
# sniffer_talk_pin: ${talk_pin} # can be replaced by the GPIO number
|
||||
|
||||
sniffer1: !include
|
||||
file: packages/bms/bms_combine_JK_RS485_Modbus_sniffer.yaml
|
||||
vars:
|
||||
sniffer_protocol: 'JK02_32S'
|
||||
sniffer_uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin} # WS-RS485-CAN and other RS485 boards with a flow_control_pin
|
||||
|
||||
# Mode2 : configure the DIP switches of your BMS from 0x01 to 0x0F (don't use the 0x00 address, maximum 15 BMS)
|
||||
bms1: !include
|
||||
|
||||
@@ -29,19 +29,12 @@ packages:
|
||||
# The sniffer represents the ESP node connected to the JK-BMS PB RS485 bus
|
||||
# If address 0x00 is not detected on the RS485 bus, the sniffer will act directly as a master BMS (mode 1, max 16 BMS)
|
||||
|
||||
# RS485 Sniffer with talk_pin (WS-RS485-CAN and other RS485 boards with a flow_control_pin)
|
||||
# sniffer1: !include
|
||||
# file: packages/bms/bms_combine_JK_RS485_Modbus_sniffer_talk_pin.yaml
|
||||
# vars:
|
||||
# sniffer_protocol: 'JK02_32S'
|
||||
# sniffer_uart_id: 'uart_esp_1'
|
||||
# sniffer_talk_pin: ${talk_pin} # can be replaced by the GPIO number
|
||||
|
||||
sniffer1: !include
|
||||
file: packages/bms/bms_combine_JK_RS485_Modbus_sniffer.yaml
|
||||
vars:
|
||||
sniffer_protocol: 'JK02_32S'
|
||||
sniffer_uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin} # WS-RS485-CAN and other RS485 boards with a flow_control_pin
|
||||
|
||||
# Mode1 : configure the DIP switches of your BMS from 0x00 to 0x0F (max 16 BMS)
|
||||
bms1: !include
|
||||
|
||||
@@ -29,19 +29,12 @@ packages:
|
||||
# The sniffer represents the ESP node connected to the JK-BMS PB RS485 bus
|
||||
# If address 0x00 is not detected on the RS485 bus, the sniffer will act directly as a master BMS (mode 2, max 15 BMS)
|
||||
|
||||
# RS485 Sniffer with talk_pin (WS-RS485-CAN and other RS485 boards with a flow_control_pin)
|
||||
# sniffer1: !include
|
||||
# file: packages/bms/bms_combine_JK_RS485_Modbus_sniffer_talk_pin.yaml
|
||||
# vars:
|
||||
# sniffer_protocol: 'JK02_32S'
|
||||
# sniffer_uart_id: 'uart_esp_1'
|
||||
# sniffer_talk_pin: ${talk_pin} # can be replaced by the GPIO number
|
||||
|
||||
sniffer1: !include
|
||||
file: packages/bms/bms_combine_JK_RS485_Modbus_sniffer.yaml
|
||||
vars:
|
||||
sniffer_protocol: 'JK02_32S'
|
||||
sniffer_uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin} # WS-RS485-CAN and other RS485 boards with a flow_control_pin
|
||||
|
||||
# Mode2 : configure the DIP switches of your BMS from 0x01 to 0x0F (don't use the 0x00 address, maximum 15 BMS)
|
||||
bms1: !include
|
||||
|
||||
@@ -36,6 +36,8 @@
|
||||
vars:
|
||||
# CAN BUS ID
|
||||
canbus_id: 'canbus_bms_1'
|
||||
canbus_platform: 'mcp2515' # esp32_can / mcp2515
|
||||
canbus_bitrate: '500kbps' # Default : 500kbps
|
||||
deye_name: 'DEYE-Top 1'
|
||||
deye_id: '1'
|
||||
# Deye module 1
|
||||
|
||||
@@ -31,17 +31,12 @@
|
||||
|
||||
################################################################################
|
||||
|
||||
# RS485 Sniffer with talk_pin (WS-RS485-CAN and other RS485 boards with a flow_control_pin)
|
||||
# - path: 'packages/bms/bms_combine_JK_RS485_Modbus_sniffer_talk_pin.yaml'
|
||||
# vars:
|
||||
# sniffer_protocol: 'JK02_32S'
|
||||
# sniffer_uart_id: 'uart_esp_1'
|
||||
# sniffer_talk_pin: ${talk_pin} # can be replaced by the GPIO number
|
||||
# RS485 Sniffer
|
||||
- path: 'packages/bms/bms_combine_JK_RS485_Modbus_sniffer.yaml'
|
||||
vars:
|
||||
sniffer_protocol: 'JK02_32S'
|
||||
sniffer_uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin} # WS-RS485-CAN and other RS485 boards with a flow_control_pin
|
||||
# BMS 1
|
||||
- path: 'packages/bms/bms_combine_JK_RS485_Modbus_JK-B_standard.yaml'
|
||||
vars:
|
||||
|
||||
@@ -31,17 +31,12 @@
|
||||
|
||||
################################################################################
|
||||
|
||||
# RS485 Sniffer with talk_pin (WS-RS485-CAN and other RS485 boards with a flow_control_pin)
|
||||
# - path: 'packages/bms/bms_combine_JK_RS485_Modbus_sniffer_talk_pin.yaml'
|
||||
# vars:
|
||||
# sniffer_protocol: 'JK02_32S'
|
||||
# sniffer_uart_id: 'uart_esp_1'
|
||||
# sniffer_talk_pin: ${talk_pin} # can be replaced by the GPIO number
|
||||
# RS485 Sniffer
|
||||
- path: 'packages/bms/bms_combine_JK_RS485_Modbus_sniffer.yaml'
|
||||
vars:
|
||||
sniffer_protocol: 'JK02_32S'
|
||||
sniffer_uart_id: 'uart_esp_1'
|
||||
# uart_flow_control_pin: ${talk_pin} # WS-RS485-CAN and other RS485 boards with a flow_control_pin
|
||||
# BMS 1
|
||||
- path: 'packages/bms/bms_combine_JK_RS485_Modbus_bms_standard.yaml'
|
||||
vars:
|
||||
|
||||
Reference in new issue
Block a user