Daily Charging/Discharging Energy (YamBMS and per BMS) were published
with 1 Wh resolution. Home Assistant records every float change, so a
new state was written every few seconds while charging or discharging.
- Add a round: 2 filter and set accuracy_decimals to 2 (0.01 kWh).
- bms_base_daily_energy 1.1.4, changelog updated.
yambms_canbus.yaml and the Deye top packages now import their node from
canbus_platform (esp32_can, mcp2515 or external). canbus_bitrate replaces
esp32_canbus_bitrate and mcp2515_canbus_bitrate. Breaking change.
Each package now imports its UART from its *_uart_id var and keeps its own baud
rate key. WK2168 channels work the same way, uart_flow_control_pin replaces the
flow control include, and min_version moves to 2026.10.0. Breaking change.
* Fix Deye power update interval
* Keep batteries the report CCL/DCL 0A
A battery that reports a charge limit (CCL) or discharge limit (DCL) of 0 A now stays in the combine. Before, a full Deye at 0 A CCL, or an empty one at 0 A DCL, dropped out of capacity, SoC and the totals.
- Missing values are still caught: a CCL or DCL with no value yet still fails >= 0, because comparisons with NaN are always false.
- No effect on the limits: CCL and DCL are added up, so a battery at 0 A adds 0 A to the total.
- All BMS models are affected
https://github.com/Sleeper85/esphome-yambms/issues/335
Several sensors had a device_class that did not match their unit, so
Home Assistant shows warnings and handles them wrongly (unit
conversion, statistics).
- Power sensors in W used device_class 'current'; now 'power'
(BASEN RS485, DEYE CAN module full/minimal, FAKE).
- Ah sensors had a device_class that does not accept Ah ('battery',
'energy', 'energy_storage'). Removed it, since Home Assistant has no
device_class for Ah (BASEN RS485, DEYE CAN module/top full/minimal,
JK RS485 Display, Modbus client).
- DEYE battery capacity used state_class 'total_increasing', but the
value is not a counter. Changed to 'measurement'.
bms_base_charging_cycles.yaml coerced a NaN raw reading to 0 before adding
the user offset, instead of letting NaN propagate like the sensors fixed
in dee203e4 ("Sensors published to NAN when no BMS is combined"). *_raw is
NaN until the first trusted BMS frame arrives after a reboot, so both
`charging cycles` and `total charging cycle capacity` published a literal
0 during that transient - with `state_class: total`, that 0 also landed
in Home Assistant's long-term statistics.
Fix is to drop the two `if (isnan(...)) = 0;` coercions and let
`NaN + offset == NaN` propagate, so both sensors go unavailable through
the transient instead of reporting 0.
Both sensors also moved from `or: [throttle: 10s, delta: 1]` to the
NaN-safe rate-limit filter already used throughout yambms_core.yaml, since
the built-in `delta` filter drops a NaN transition without updating its
reference and would otherwise freeze the sensor on its last value for up
to 10s.
That filter is extracted from yambms_core.yaml into
packages/base/device_base.yaml, which every node loads via its board_*.yaml
regardless of whether it runs the YamBMS engine - unlike yambms_core.yaml,
which is absent from a multi-node Modbus-server node that only exposes
BMS/Shunt packages. Renamed yambms_rate_limit_filter to rate_limit_filter
now that it is no longer engine-specific.
Some BMS balance their cells but never expose a balancing flag, so
`bms_equalizing` stays false and the core cannot tell a pack that is still
balancing from one that has finished. This is not cosmetic : while
equalizing is true, yambms_core.yaml stops the Cut-Off timer and lets the
charge run to the EOC timer instead of terminating early.
bms_options_fake_equalizing.yaml infers that flag from the pack itself. No
absolute cell voltage is hardcoded : the anchor is bulk_voltage / cell
count, the same derivation as cell_bulk_v in yambms_core.yaml, so it
follows `yambms_battery_chemistry`, the cell count and the configured bulk
voltage automatically.
START when BOTH are true
max cell >= cell_bulk_v the pack is at the setpoint
AND (max - min) >= trigger voltage its own balancing threshold
STOP when EITHER is true
max cell < cell_bulk_v - hysteresis the pack dropped off the setpoint
OR (max - min) < trigger - delta hyst. the spread closed back below it
Only two deltas and one offset are configurable, and none of the three
depends on the chemistry - LFP, Li-ion and LTO all want the same few tens
of mV. The absolute anchor they hang off comes from the core, for free.
The delta condition is what keeps this honest : a pack that reaches the
setpoint perfectly balanced has nothing to equalize, so it reports false
and the Cut-Off timer does its job. A plain voltage comparison would report
balancing forever and terminate every charge on the EOC timer.
It extends bms<id>_bms_equalizing, the raw BMS flag, and not the combined
bms<id>_equalizing sensor. bms_base_balancer.yaml is therefore neither
modified nor duplicated, and keeps giving an external balancer priority
whenever one is online : the inference only applies when no balancer
reports for this pack.
This commit only adds the package. Nothing includes it yet, so no existing
configuration changes behaviour. Candidates sharing the same case are
Seplos V3, Seplos V1/V2, EG4 LL V2 and JK RS485 DISPLAY, whose
bms_equalizing is a hardcoded `return false;`.
The installed total was accumulated once per BMS per boot, latched by
bms<id>_combined_once, so a BMS reconfigured with a different capacity
kept contributing its boot value until the next reboot.
Each BMS now remembers the last capacity it contributed in
bms<id>_installed_capacity and applies only the difference to the total.
- the update runs in the can_be_combined branch, so an offline BMS simply
stops updating its contribution, which stays in the total : the installed
capacity still never shrinks on an uncombine, as before
- a BMS coming back with a different capacity is applied as a delta, with
no double counting
- combined_once had no other reader and is removed
The total is deliberately not turned into a per-round accumulator reset in
the Global vars reset block like the other totals : its sensor is polled
independently of STEP 2 and its state is written straight into CAN frame
0x379 with no has_state() guard, so a transient zero would announce 0 Ah of
installed capacity to the inverter. See Design_decisions.md.
* Update EG4 LL-V2 component to v1.1.0
FixesRAR/esphome-eg4-bms#7: some EG4 LL-V2 units intermittently answer
with a CRC-valid function-03 response whose register data area is
entirely zero. The component published those zeroes as a real reading,
collapsing SoC, pack voltage and capacity for one poll cycle.
v1.1.0 rejects implausible blocks and no longer lets them refresh the
online tracker, so a unit stuck returning zeroes now goes offline
instead of reporting a flat-zero battery.
No YamBMS-side changes are required: neither EG4 package uses the
removed designed_capacity sensor, and both already use the
cell_average_voltage key.
Add switch to enable/disable communication with Basen BMS. For example
this can be used during maintenance to disable communication with the
selected battery.