Sleeper85 2cdc61e8b4 Fixed Auto CVL Float lockup at Rebulk threshold
Rewrote Auto CVL from template sensor lambdas to interval
lambdas, splitting each into a value sensor and a delta sensor.

Fixed a bug confirmed in production: Auto CVL's Float floor coincided
exactly with the Rebulk V. threshold, letting it trigger its own rebulk.
The floor is now capped relative to the live target instead of a fixed
chemistry constant, the Float/Stop integral term can no longer get stuck
once clamped, and PI state now resets when crossing the Bulk <-> Float/Stop
boundary.